Vighnaharta TrueSense CO-DETECTOR User Manual

Advertisement

Quick Links

Doc No.: TSCO_UM_1_1
Rev No.: 1_1
Eff Date: 04/11/2015
Mfg. By:
Vighnaharta Technologies Pvt. Ltd.
2nd Floor,Karanjkar Estate,S.N.11/11,Nanded Gaon,Pune-411041
Contact no.: +919011033259 (Landline)
Email: sales@vighnaharta.in | Website: http://www.vighnaharta.in
Vighnaharta Technologies Pvt. Ltd.
2nd Floor,Karanjkar Estate,
S.N.11/11,Nanded Gaon,
Pune-411041
Tel no.: +919011033259, Sales: +919011033260
Email: sales@vighnaharta.in | Website: http://www.vighnaharta.in
Prepared By:
Ganesh
Approved By:
C O - D E T E C T O R
U S E R M A N U A L
Sales: +919011033260

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TrueSense CO-DETECTOR and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Vighnaharta TrueSense CO-DETECTOR

  • Page 1 Vighnaharta Technologies Pvt. Ltd. 2nd Floor,Karanjkar Estate, S.N.11/11,Nanded Gaon, Pune-411041 Tel no.: +919011033259, Sales: +919011033260 Email: sales@vighnaharta.in | Website: http://www.vighnaharta.in Doc No.: TSCO_UM_1_1 Prepared By: Ganesh Rev No.: 1_1 Approved By: Eff Date: 04/11/2015 C O - D E T E C T O R U S E R M A N U A L Mfg.
  • Page 2 TrueSafe CO User Manual Table Of Contents Overview: ......................III Technical Specifications ..................IV Installation Procedure: ................... V Getting Started ....................VI How does Co Detector work? ................VII Vighnaharta Technologies Pvt. Ltd. Page 2 of 8...
  • Page 3 CO Detector. Highlighted Features: Detect dangerous level of Carbon Monoxide gas. Electrochemical CO sensor module. Fast response and Portable device. Battery Operated. Long life Protection. Visual and audible indications with 80dB sound level. Vighnaharta Technologies Pvt. Ltd. Page 3 of 8...
  • Page 4 Red LED: Alarm Condition Output Buzzer Output : > 85 decibels (dB) at 3m Size ( 111x89x38)mm ( L x H x W ) Operating Temperature -20C° to 55C° Humidity 0 to 95 % Rh. Vighnaharta Technologies Pvt. Ltd. Page 4 of 8...
  • Page 5 1. Level the cabinet on sturdy wall and mark the mounting holes with a pencil. Note: The height of the unit from the flooring must be high. 2. Insert the screws into the mounting hole partially and hang the cabinet on middle hole. Vighnaharta Technologies Pvt. Ltd. Page 5 of 8...
  • Page 6 When user power ON the Co Detector then System will check itself and it will show some indications to user that device is in working state, given below: Power ON Indications will be: RED and GREEN LED will flash with buzzer for 200ms Vighnaharta Technologies Pvt. Ltd. Page 6 of 8...
  • Page 7 30 minute. Using “Test Key” user can stop the buzzer Co Concentration in (PPM) No Alarm Before Alarm Before 120 Min 60 Min 90 Min 10 Min 40 Min 3 Min Vighnaharta Technologies Pvt. Ltd. Page 7 of 8...
  • Page 8 1. During Idle condition if the test key is pressed the buzzer will beep and leds will blink. 2. During Alert condition if the test key is pressed the CO detector will go out of alert condition and will get reset. Vighnaharta Technologies Pvt. Ltd. Page 8 of 8...

Table of Contents