AntMiner FAQ
Q: How to reset antMiner to the default state?
A: S2 is the reset button in the second version of control board, but there is no reset button in the
first version of control board. If AntMiner has to be reset, please follow these steps.
Step 1: Set your PC's IP address as 192.168.2.x or 192.168.1.x, and then connect AntMiner with
your PC via a network cable.
Step2: Power on AntMiner for a while when it is in the normal state. The WAN LED should be light.
Step3: For the second version of control board, please press button S2 for more than 3 seconds.
For the first version of control board, please short the RESET PIN to 3.3V as the following picture
for more than 3 seconds.
Step4: Re-power antMiner. Ping 192.168.2.99 or 192.168.1.99. Note: from the version 20131212
of openwrt, the default IP is 192.168.1.99
Figure 1 Second batch of control board

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the S1 and is the answer not in the manual?

Questions and answers

Summary of Contents for Antminer S1

  • Page 1 PC via a network cable. Step2: Power on AntMiner for a while when it is in the normal state. The WAN LED should be light. Step3: For the second version of control board, please press button S2 for more than 3 seconds.
  • Page 2 Last updated: 12/15/2013 Page 2 of 4 Figure 2 First batch of control board Q: How to fix Network Time Protocol daemon (NTPD) Error? Error: In some special network environment, NTPD server can’t be accessed and it is failed to start cgminer.
  • Page 3 Last updated: 12/15/2013 Page 3 of 4 Step2: Disable NTPD client for linux. Step3: Re-power AntMiner. Q: How to change the clock frequency of AntMiner? Timeout for 32-chip chain Freqency (MHz) ASIC hash rate (GHz) ASIC Hex Value (ms) 0581...
  • Page 4 Last updated: 12/15/2013 Page 4 of 4 0A81 0B81 4C81 4D81 4E81 4F81 5081 5181 5281 5381...

Table of Contents