  • Page 1 82048 Turino Bath Ventilator with Light READ and SAVE THESE INSTRUCTIONS 43042-01 02/21/2008...
  • Page 2: Power Supply

    10. This unit must be grounded. 11. Unit must not be installed in a ceiling thermally insulated to a value greater than r40. DisConnECT ELECTriC sErViCE panEL BEForE 43042-01 02/21/2008 W a r n i n G poWEr sUppLY anD LoCK oUT sErViCinG UniT...
  • Page 3 95044-01-000 95029-01-000 75191-01-000 03242-07-133 98037-01-000 74508-03-133 77521-01-000 65219-01-000 97959-01-000 75729-01-000 75184-01-133 97960-01-000 77535-01-000 3/8” Cable Connector noTE: strain relief cable connector must be installed. not included. included. Tools needed. Estimated assembly time: 30 to 60 minutes 43042-01 02/21/2008 Extra screws...
  • Page 4: Before Installation

    Turn off the power source. Loosen screws. remove the motor/blower from the housing. remove packing material. remove the pre-loaded screw tip covers. Back out the pre-loaded screw tips until flush with the side of the housing. 43042-01 02/21/2008...
  • Page 5 For new Construction - suspended between joists go to step B11, page 8 For Existing Construction - accessible from above go to step C11, page 11 For Existing Construction - accessible only from below go to step D11, page 15 43042-01 02/21/2008...
  • Page 6 3 pin Light Black Light *option *option Fan & Main Light Together screw pre-loaded screws into joist or framing. Ground Green Bare Copper Black Main switch 1 (aC in) Black Connect wires as shown. 43042-01 02/21/2008 White switch 2 (aC in)
  • Page 7 Make sure the wires are not pinched between the motor and the housing. secure the motor by tightening the 2 screws. Turn on the power source. 43042-01 02/21/2008...
  • Page 8 Mark position of screws by using holes as a template. position the correct depth mark at the bottom edge of the joist based on the thickness of your sheetrock. Drill a hole in the center of each outline. 43042-01 02/21/2008 Go to step on page 18 to attach grille.
  • Page 9 Black Light Light *option Fan & Main Light Together Ground Green *option Connect wires as shown. 43042-01 02/21/2008 attach the rails onto the screws. pull wires through the strain relief. Bare Copper Black Main switch 1 (aC in) White Black...
  • Page 10 Make sure the wires are not pinched between the motor and the housing. secure the motor by tightening the 2 screws. Turn on the power source. 43042-01 02/21/2008...
  • Page 11 Use the motor housing as a template to mark position. opening is large enough to accommodate the new motor housing (8”x 8.5”). Cut out an opening for the housing. slide the mounting rails into brackets. 43042-01 02/21/2008...
  • Page 12 Drill a hole in the center of each outline. attach the rails onto the screws. Mark position of screws by using holes as a template. 1/8" Bit insert screws, leaving space between the screw head 43042-01 02/21/2008 and the joist. screws are not provided. Tighten screws.
  • Page 13 3 pin Black Light Light *option Fan & Main Light Together Ground Green *option Connect wires as shown. 43042-01 02/21/2008 pull wires through the strain relief. Bare Copper Black Main switch 1 (aC in) White Black switch 2 (aC in)
  • Page 14 2 screws. position. Make sure the wires are not pinched between the motor and the housing. Turn on the power source. Test the motor. if the motor does not run, check the plug connection. 43042-01 02/21/2008...
  • Page 15 Move the housing into position above the ceiling. is large enough to accommodate the new motor housing (8”x 8.5”). attach existing ducting to duct connector. Tape joints. pull wires through strain relief if ducting does not fit securely, an adapter may need to be purchased. 43042-01 02/21/2008...
  • Page 16 Ground Black Green White White Black Light *option Connect wires as shown. Connect wiring from the motor to the wiring cover plate. 43042-01 02/21/2008 Bare Copper Black Main switch 1 (aC in) White Black switch 2 (aC in)
  • Page 17 Make sure the wires are not pinched between the mo- tor and the housing. Turn on the power source. Test the motor. if the motor does not run, check the plug con- nection. Go to step on page 18 to attach grille. 43042-01 02/21/2008...
  • Page 18 B, C and D (stamped into motor housing) with over the lip of the motor. reinstall the strain relief bracket posts a, B, C and D (stamped into light fixture). slide light screw. fixture over posts. 43042-01 02/21/2008...
  • Page 19 2 Max 60 Watt a15 bulbs (not included). WarninG: To reduce the risk of electrical shock, all 4 thumbscrews MUsT be properly installed. screw glass stop into position. align glass dome and push up. Complete. screw Finial into position 43042-01 02/21/2008...
  • Page 20: Troubleshooting

    Fan does not come on. solution: • Hunter Fan Bath Ventilators are extremely quiet. To confirm that the fan is running, place your hand near the vents to feel the air movement. • Turn power on, replace fuse, or reset breaker.
  • Page 21: Limited Warranty

    Hunter Fan Company Bath Exhaust Fan LiMiTED WarranTY Hunter Fan Company makes the following limited warranty to the original user or consumer purchaser of this Hunter bath exhaust fan: If any part of your Hunter bath exhaust fan (except for glass fixtures and light bulbs) fails at any time within one year...