AERMEC DML 100 Instruction Manual
AERMEC DML 100 Instruction Manual

AERMEC DML 100 Instruction Manual

Portable dehumidifier

Advertisement

Quick Links

EN
2 0 . 1 2 - 5 5 0 7 5 1 0 _ 0 1
T r a n s l a t i o n f r o m o r i g i n a l
D M L
1 0 0 - 1 2 0
I n s t a l l a t i o n m a n u a l
PORTABLE DEHUMIDIFIER
D e h u m i d i f i c a t i o n c a p a c i t y o f 5 , 8 l / 2 4 h a t 1 2 , 0 l / 2 4 h
w w w . a e r m e c . c o m

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DML 100 and is the answer not in the manual?

Questions and answers

Summary of Contents for AERMEC DML 100

  • Page 1 2 0 . 1 2 - 5 5 0 7 5 1 0 _ 0 1 T r a n s l a t i o n f r o m o r i g i n a l D M L 1 0 0 - 1 2 0 I n s t a l l a t i o n m a n u a l ■...
  • Page 2 Dear customer, Thank you for choosing an AERMEC product. It is the fruit of many years of experience and special design studies and has been made of the highest grade materials and with cutting edge technology. In addition, all our products bear the CE mark indicating that they meet the requirements of the European Machine Directive regarding safety.
  • Page 3: Table Of Contents

    CONTENTS SAFETY STANDARDS - R290 GAS ....................................4 WARNINGS ..............................................7 SUPPLIED MATERIAL ..........................................10 RECEIVING THE PRODUCT .......................................10 TECHNICAL DATA ..........................................11 UNIT TYPE ...............................................12 FEATURES ..............................................12 UNIT PARTS ............................................13 CONTROL PANEL ..........................................14 FUNCTIONS ............................................14 SIZES AND WEIGHTS ..........................................15 MINIMUM TECHNICAL CLEARANCES ..................................16 NOTES FOR UNIT INSTALLATION ....................................17 CONTROLS TO PERFORM BEFORE STARTING-UP ..............................18 CONDENSATE DISCHARGE ......................................19...
  • Page 4: Safety Standards - R290 Gas

    SAFETY STANDARDS - R290 GAS REFRIGERANT GAS LEAKAGE TEST • Do not use halogen probes, or other probes or detection devices that use naked flames, when WARNING testing for possible refrigerant leakages. This unit uses a flammable R290 re- • Use electronic measuring devices such as a leak frigerant.
  • Page 5 REFRIGERANT CHARGE SAFETY STANDARDS FOR REFRIGERANT DISPOSAL AND RECOVERY These procedures must only be carried out by specialised technicians or qualified personnel. These procedures must only be carried out by specialised technicians or qualified personnel. • Make sure no other type of refrigerant can contaminate the refrigerant gas.
  • Page 6 • If necessary, adopt anti-electrostatic measures during transportation. During transportation, loading and unloading, adopt the necessary measures to protect the unit and ensure it is not damaged in any way. • When removing the compressor or cleaning it to eliminate the residual oil, make sure there is no R290 refrigerant residue.
  • Page 7: Warnings

    WARNINGS • Do not install the unit in a location where it could be affected by inflammable gas leaks or deposits of materials which are inflammable, explosive, poisonous, corrosive or hazardous substances. Do WARNING: Strictly observe the warnings below. Failure not use naked flames near the units.
  • Page 8 hazards involved. Children must not play with the used by a lot of people or if there are gas devices. unit! Cleaning and maintenance intended to be Insufficient ventilation may result in a lack of oxygen. performed by the user should not be performed by •...
  • Page 9 DISCLAIMER AERMEC DOES NOT ASSUME ANY RESPONSIBILITY FOR DAMAGES TO THE UNIT OR WARRANTY LOSS IN CASE: 1. The unit is used improperly. 2. Attempts to modify, alter or repair the unit were made without following the previously mentioned instructions.
  • Page 10: Supplied Material

    Placed on the packaging, displays the data identifying the The technical plate located inside the unit, displays the product. product's technical and identifying data. AERMEC S.p.A. VIA ROMA 966 BEVILACQUA (VR) ITALY AERMEC S.p.A. VIA ROMA 996 BEVILACQUA (VR) ITALY...
  • Page 11: Technical Data

    TECHNICAL DATA DML100 DML120 Nominal performance (1) l/24h 10,1 12,0 Dehumidification capacity Input power Absorbed current Nominal performance (EN 810 normative) (2) l/24h Dehumidification capacity Electric data Rated power input Rated current input kWh/60min Hourly electricity consumption Compressor type Reciprocating Type type R290...
  • Page 12: Unit Type

    UNIT TYPE FEATURES The portable dehumidifiers in the DML range are ideal • New natural refrigerant gas R290. • Unit front panel with LED display and indicator for the dehumidification of domestic environments lights. such as rooms, cellars, bathrooms and areas where the •...
  • Page 13: Unit Parts

    PARTS OF THE UNIT Control panel Return air Condensate discharge tray Castors Supply air Power cable with schuko plug Removable panel for connecting the condensate discharge pipe...
  • Page 14: Control Panel

    CONTROL PANEL Switches the unit on or off Increases or decreases the humidity level LED display Resets the filter cleaning reminder Filter cleaning reminder LED indicator Automatic continuous operation LED indicator LED indicator, indicates that the condensate discharge basin is full or incorrectly positioned LED indicator, indicates that the unit is operating...
  • Page 15: Sizes And Weights

    SIZES AND WEIGHTS Carton box example Gross Without With weight weight packaging (mm) (mm) (mm) packaging (mm) (mm) (mm) (kg) (kg) DML100 DML100 DML120 DML120...
  • Page 16: Minimum Technical Clearances

    MINIMUM TECHNICAL CLEARANCES CHOOSING THE INSTALLATION AREA • The unit is intended only for use in indoor residential environments. Do not use the unit for commercial or industrial applications. • It is recommended to position the unit on a smooth and flat floor.
  • Page 17: Notes For Unit Installation

    INSTALLATION INSTALLATION POSITION NOTES FOR UNIT INSTALLATION • Install on a solid surface that can hold the weight of the unit. WARNINGS CONCERNING INSTALLATION • Avoid places within the reach of children. • Avoid exposure to other heat sources or to direct The unit and its accessories must only be installed and sunlight.
  • Page 18: Controls To Perform Before Starting-Up

    CONTROLS TO PERFORM BEFORE STARTING- Before starting the unit for the first time, first check that the float is positioned correctly. The steps to follow are described below: 1. Grasp the handles on both sides of the condensate water drip tray and remove it in the direction of the arrow.
  • Page 19: Condensate Discharge

    CONDENSATE DISCHARGE METHOD 2: Condensate discharge diameter (mm) Ø CONDENSATE DISCHARGE DUE TO GRAVITY 1. Grasp the handles on both sides of the condensate NOTE water drip tray and remove it in the direction of the Do not remove the condensate discharge tray while arrow.
  • Page 20: Electrical Connections

    ELECTRICAL CONNECTIONS NOTES: • Before carrying out any work, switch off the power supply to the unit. • The thermomagnetic switch and the cross-section • Incorrect connection could cause the air conditioner of the cables are dimensioned in relation to the to malfunction or suffer damage.
  • Page 21: Wiring Diagrams

    WIRING DIAGRAMS WATER HUMIDITY SENSOR LEVEL SWITCH MOTOR FAN N2 BN(BK) AC-L BU(WH) DISPLAY YEGN(GN) BOARD TUBE MAIN BOARD POWER COMP TUBE TEMP.SENSOR COMP YEGN COMP. 600007061420 CODE DESCRIPTION AP1 (MAIN BOARD) Main board AP2 (DISPLAY BOARD) Display card Brown Blue COMP Compressor...
  • Page 22: Checks To Be Carried Out After Installation

    CHECKS TO BE CARRIED OUT AFTER INSTALLATION ITEMS TO CHECK POSSIBLE ANOMALY NOTES The unit has been positioned on a level The unit could fall, vibrate or generate surface. noise. Has a check for refrigerant leaks been Poor performance. performed? Does the unit correctly drain the It could cause condensate and dripping condensate water?
  • Page 23: Maintenance

    MAINTENANCE • Check that the air intake and supply is not blocked by objects. • Make sure the earthing cable is connected and not GENERAL NOTES damaged. • Check to make sure the air filter is clean. • Disconnect the power supply and wait 5 minutes •...
  • Page 24: Troubleshooting

    TROUBLESHOOTING Before contacting the company, perform the following checks. If the problem persists, please contact the company Irregularity Possible reasons • No power supply. • Check whether the supply cable is damaged. • Make sure there are no supply anomalies. •...
  • Page 25 Irregularity Possible reasons Solutions • Check for obstructions in the • Remove the obstruction from condensate discharge pipe. the condensate discharge pipe. When the condensate discharge pipe is used, there is water in the • Remove the drain pipe and •...
  • Page 26: Alarms Table

    ALARMS TABLE If malfunctioning occurs during system functioning, the units show the relative alarm code which easily permits to the After-Sales Service Area to identify the cause of errors; this error code is displayed on the unit; the following table indicates the alarm codes and their causes.
  • Page 28 TÉLÉCHARGER LA DERNIÈRE VERSION: TÉLÉCHARGER LA DERNIÈRE VERSION: http://www.aermec.com/qrcode.asp?q=15198 http://www.aermec.com/qrcode.asp?q=15199 http://www.aermec.com/qrcode.asp?q=15200 A E R M E C S . p . A . V i a R o m a , 9 9 6 - 3 7 0 4 0 B e v i l a c q u a ( V R ) - I t a l y T e l .