  • Page 1 CGEO INTERNATIONAL LIMITED CGEO-TEM2 Resistance Temperature Sensor Installation Manual (REV A)...
  • Page 2: Table Of Contents

    Contents 1. Brief Introduction........................1 2. Main Specifications ......................1 3. Cable Welding Lengthening ....................2 4. Using Surroundings & Installation Notice ................3 5. Operation & Data Process ..................... 3 6. Temperature Calculation Formula ..................4 7. Trouble Shooting ........................5...
  • Page 3: Brief Introduction

    CGEO-TEM2 Resistance Temperature Sensor 1. Brief Introduction CGEO-TEM2 Thermometer is composed of a stainless steel crust, thermo-resistance, and the CGEO-4-SCT special cable with the outstanding water-proof capability and signal stability. It is widely used in temperature controlling and monitoring of high technology, industrial production and science research and other areas.
  • Page 4: Cable Welding Lengthening

    BSIL-T2-1.1 Instruction Manual Cable Welding Lengthening A standard CGEO-TEM2 model temperature gauge equips with 1m cable in ex-factory, cable model is CGEO-4-SCT. For cable lengthening adopted is CGEO-4-SCT dedicated cable, and BSIL-4-SC cable as well as. Proceed lengthening basing on the field circumstance before installation.
  • Page 5: Using Surroundings & Installation Notice

    Figure 5 Cable welding splice diagram 4. Using Surroundings & Installation Notice Though the CGEO-TEM2 Temperature Transducer can be used in all atrocious environments, it is still necessary to avoid using in the area which is over the standard range (with the exception of the customized), and avoid long-time using in strong acid and alkaline areas.
  • Page 6: Temperature Calculation Formula

    There are no polarity difference in signal lines of CGEO-TEM2 thermometer, green, white wire are changeable. Temperature Calculation Formula ...
  • Page 7: Trouble Shooting

    This resistance will not be taken into consideration under low-temperature environment. The resistance of matched cable core is about 50Ω/1000m, and doubled when in two-direction. Appendix A: Resistance versus Temperature Table CGEO INTERNATIONAL LIMITED Installation Manual...
  • Page 8 3277 670.4 186.8 65.5 23.16K 3135 647.1 181.5 64.0 21.89K 3000 624.7 176.4 62.5 20.70K 2872 603.3 171.4 61.1 19.58K 2750 582.6 166.7 59.6 18.52K 2633 562.8 162.0 58.3 17.53K 2523 543.7 157.6 56.8 55.6 CGEO INTERNATIONAL LIMITED Installation Manual...
  • Page 9 BSIL-T2-1.1 Instruction Manual CGEO-TEM2 Semiconductor Thermometer Control Table of Resistance - Temperature CGEO INTERNATIONAL LIMITED Installation Manual...