Advertisement

Quick Links

INSTRUCTION MANUAL
Mega Combos
G E N E R A L I N S T R U C T I O N S
MEGA WET/DRY COMBOS – OVERVIEW
OPERATOR/ATTENDANTS ARE RESPONSIBLE FOR THE PATRONS SAFETY, AT ALL TIMES!
Secondary escape
opening in roof
GFCI extension required
(reduces possibility of shock)
Use Ground Cover Tarps
(to protect inflatable)
Must be positioned on
a FLAT, LEVEL SURFACE
Commercial Inflatable Blowers needed
1.5 HP / producing minimum 700 cfm @ 4.5˝
(consult manufacture´s safety label for requirements)

SET-UP STEP 1. (SAFETY CHECK LIST)

716 832-TENT (
8368 )
Keep individuals
OUT of blower
areas, at all times
2 trained operator/
attendants are required
to supervise this device,
at all times
Anchor Straps at base—secure
with recommended stakes
(refer to your state inspection requirements)
CHECK ALL SPECIFICATIONS
LOCATED ON SAFETY LABEL–
ATTACHED TO YOUR UNIT
WARNING: Inflatables are very heavy
—do not attempt to roll or move these
games by yourself
• Do not inflate in high winds or rain—
High winds are considered to be
15 mph or higher
• Inspect the site, look for overhead and
underground obstructions— such as
utilities
• Call your local utility to have utility
lines marked (call 3–5 days ahead)—
call811.com is a good resource—
'click' 811 in Your State
• Use an adequate three wire extension
cord, min. 12 gauge for 50ft. maximum
length—never cut or remove the round
grounding pin from the cord
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Mega Combos and is the answer not in the manual?

Questions and answers

Summary of Contents for Tentandtable.com Mega Combos

  • Page 1 FLAT, LEVEL SURFACE (refer to your state inspection requirements) Commercial Inflatable Blowers needed CHECK ALL SPECIFICATIONS Mega Combos 1.5 HP / producing minimum 700 cfm @ 4.5˝ LOCATED ON SAFETY LABEL– ATTACHED TO YOUR UNIT (consult manufacture´s safety label for requirements) WARNING: Inflatables are very heavy...
  • Page 2 716 832-TENT ( 8368 ) 716 832-TENT ( 8368 ) • Plug the blower power cord into the GFCI SET-UP STEP 4. (INFLATION TUBES) SET-UP (SAFETY CHECK LIST - cont.) • Always connect a GFCI extension cord extension, then plug the GFCI extension adapter to any extension cord before into the extension cord—...
  • Page 3 716 832-TENT ( 8368 ) 716 832-TENT ( 8368 ) • People with medical conditions or severe OPERATING INSTRUCTIONS - cont. DEFLATION AND FOLDING disabilities should not use this Inflatable • Before deflating; Inspect for any damage amusement device and repair as necessary •...
  • Page 4 716 832-TENT ( 8368 ) 716 832-TENT ( 8368 ) DIRECTIONS FOR USE: • Fold both sides into the center of the FINAL FOLD AND ROLL inflatable—each person should place one (operator/attendants should be assisting patrons as they enter and exit the Inflatable/Deflation foot on the inflatable at the fold line inflatable amusement device)
  • Page 5 PatchALL are clear polyurethane patches or tape. They are quick, flexible, long lasting, airtight and waterproof—with no gluing. Staking for this Device: (6) total — 6 anchor straps / 0 tie downs Visit TentAndTable.com for all your Inflatable Accessories including; blowers, impact mats, dollies, heavy-duty hand trucks and repair kits.
  • Page 6 716 832-TENT ( 8368 ) 716 832-TENT ( 8368 ) WARNING: SAFETY RULES Bladder Use and Replacement Instructions: As with any Amusement Device, ADULT SUPERVISION REQUIRED AT ALL TIMES! Inflatable and Combo Devices with slides use a BLADDER system to keep the slide wet. there is an inherent risk They are included with every new inflatable slide device.

Table of Contents