Download Print this page

ACM DMDPW Operation Manual

Dc multifunction power meter

Advertisement

Quick Links

□ □ □ □ Operation Panel
9 9 9 9
A
V
9 9 9 9
B
A
9 9 9 9
C
W
□ □ □ □ Keys
Key
Function
S
SET
Change number
Change position
〝 〝 〝 〝 S〞 〞 〞 〞 + 〝 〝 〝 〝 → → → → 〞 〞 〞 〞 Reset the value
□ □ □ □ Parameter Setting
Press
S
to enter function selection (01~09).
〝↑〞
Press
to change number. Press
Function
Press↑ and → to set.
Voltage ratio
01
setting
Press
〝S〞
Press↑ and → to set.
Ampere ratio
02
setting
Press
〝S〞
Press↑to choose ratio 1 or 1000
03
Watt unit ratio
Press
〝S〞
Press↑ and → to set.
Decimal point
04
Change decimal point
setting
〝S〞
Press
05
XXXXXXXX
Press
〝S〞
06
XXXXXXXX
Press
〝S〞
Press↑to choose Baud Rate
Baud rate
and
(9600-19200-38400-2400-4800)
07
Address
Press SET to set Address 1~255.
Press
〝S〞
〝S〞
08
XXXXXXXX
Press
Press
〝S〞
09
Save
Key in99 and press
**All parameters are preset by our
**All parameters are preset by
our factory for you. Please refer to the
factory for you. Please refer to the instructions
**All parameters are preset by
**All parameters are preset by
our
our
factory for you. Please refer to the
factory for you. Please refer to the
S
S e t
C h a n g e n u m b e r
C h a n g e p o sitio n
W H A u to p a g e -tu rn in g
1 0 D ig its d is p la y
O p e ra tio n k e y
3 9 9 9
D is p la y
9 9 9 9 9 9 W H
A la rm s ta te
R e m o v e th e p a n e l lid to se t
Instruction
Enter setting mode.
Set and change number
Change position
Press〝 〝 〝 〝 S〞 〞 〞 〞 and〝 〝 〝 〝 → → → → 〞 〞 〞 〞 to reset the value (WH).
〝→〞
to change position.
Operation
Instruction
Ex: Input range DC 0~50 V.
to enter 02.
Set 01 as 5000
Ex: Input range DC 0~20A
to enter 03.
Set 02 as 2000
Ratio: W =1 ,KW=1000
to enter 04
Set as KW when over 9999 W
Hundreds =V decimal point.
Tens = A decimal point.
Units= W/WH decimal point.
0 0 0 0
Number means how many
to enter 05
digits after decimal point.
to enter 06
No need to set.
to enter 07
No need to set.
Max. Baud rate: 38400
Address:1-255
to enter 08
to enter 09
No need to set.
to enter 89.
Any setting needs to be saved
〝S〞
to save.
by keying in 99.
instructions if you need to do any alterations.
if you need to do any alterations.
instructions
instructions
if you need to do any alterations.
if you need to do any alterations.
□ □ □ □ Alarm Hi-Lo setting.
Press〝 〝 〝 〝 S〞 〞 〞 〞 to enter〝 〝 〝 〝 00 〞 〞 〞 〞 .Press〝 〝 〝 〝 → → → → 〞 〞 〞 〞 to enter〝 〝 〝 〝 51〞 〞 〞 〞 to set.
Function
51
S1 value setting 0~9999
S1 deadband setting 0~9999
52
53
S1 delay time 0~99 secs
54
S2 value setting 0~9999
S2 deadband setting 0~9999
55
56
S2 delay time 0~99 secs
57
S1;S2 HI-LO setting
Start Delay Time 0~99 secs
58
59
SAVE
The S3 S4 alarm setting procedure is the same as explained above.
Press〝S〞to enter〝00 〞.Press〝↑〞to enter 61-62-63-64-65-66-67 setting selection.
□ □ □ □ Example:
1. Input: Voltage DC 50V Current 20A W=50*20= 1000 W
Set 01(Voltage ratio) as 5000
02(Current ratio) as 2000
03(Watt ratio ) as 1 (unit is W)
04(Decimal point) as 0 2 2 0
2. Input: Voltage DC 600V Current 1000A/50mv W=600V*1000A=600.0KW
Set 01(Voltage ratio) as 6000
02(Current ratio) as 1000
03(Watt ratio ) as 6000 (unit is KW)
04(Decimal point) as 0 1 0 1
Note
:
*All parameters were preset by our factory according to your order specifications.
*If Watt value is blinking, please check if the V, A, W decimal point setting is correct.
Instruction
Press〝↑〞and〝→〞to set S1 value.
Press〝S〞to enter 52.
Press〝↑〞and〝→〞to set S1 deadband.
Press〝S〞to enter 53.
Press〝↑〞and〝→〞to set S1 delay time
Press〝S〞to enter 54.
Press〝↑〞and〝→〞to set S2 value.
Press〝S〞to enter 55
Press〝↑〞and〝→〞to set S2 deadband.
Press〝S〞to enter 56
Press〝↑〞and〝→〞to set S2 delay time.
Press〝S〞to enter 57
Press〝↑〞and〝→〞to set the HI-LO function.
(1=Hi. 0=Lo) Hi-Hi. Hi-Lo. Lo-Hi. Lo-Lo.(selectable).
Press〝S〞to enter 58
Press〝↑〞and〝→〞to set the number as 99.
Set the delaytime from 0~99.Alarm has no action within the
set time. Press〝S 〞to enter 59.
Press〝S〞to enter 89.
Press〝↑〞and〝→〞to key in 99.
Press〝S〞to save.
V= 50.00
A= 20.00 W= 1000
V=600.0
A=1000 W=600.0KW

Advertisement

loading
Need help?

Need help?

Do you have a question about the DMDPW and is the answer not in the manual?

Questions and answers

Summary of Contents for ACM DMDPW

  • Page 1 □ □ □ □ Operation Panel □ □ □ □ Alarm Hi-Lo setting. Press〝 〝 〝 〝 S〞 〞 〞 〞 to enter〝 〝 〝 〝 00 〞 〞 〞 〞 .Press〝 〝 〝 〝 → → → → 〞 〞 〞 〞 to enter〝 〝 〝 〝 51〞 〞 〞 〞 to set. Function Instruction 9 9 9 9...
  • Page 2 DATA CRC16 8 Bits 8 Bits 8 Bits 4 Byte LSB MSB 00H 00H 11H 1DH 35H 69H Model: Model: Model: Model:DMDPW DMDPW DMDPW DMDPW Values/Address Cross-reference (Refer to ModScan32) Address Length Name Instruction (R/Read .W/Write) 40002 1Word V value...