Input States Trouble Inputs Battery Events Access Control Creating a Credential Type Creating a Door Type and Linking to Credential Type and Door Linking an Inovonics Module to a Door PRT-IVO-IF | Protege Inovonics Wireless Receiver Module | Installation Manual...
Page 4
Linking to a User Error Code Indication Error Code Display Mechanical Diagram Mechanical Layout Technical Specifications New Zealand and Australia European Standards FCC Compliance Statements Industry Canada Statement Disclaimer and Warranty PRT-IVO-IF | Protege Inovonics Wireless Receiver Module | Installation Manual...
The receiver module is available in two unit types suitable for the following frequencies: ⦁ PRT-IVO-IF: for use in the US (902-928 MHz), Australia (915-928 MHz), and New Zealand (922-928 MHz) ⦁ PRT-IVO-IF-EU: for use in the EU region (868-870 MHz) Note: the Inovonics receiver module integrates with both Protege GX and Protege WX systems.
Installation Requirements This equipment is to be installed in accordance with: The product installation instructions ⦁ AS/NZS 2201.1 Intruder Alarm Systems ⦁ The Local Authority Having Jurisdiction (AHJ) ⦁ PRT-IVO-IF | Protege Inovonics Wireless Receiver Module | Installation Manual...
(RS-485 N+, N-, NA, NB) DIN Rail Enclosure Additional DIN Rail Enclosure(s) Controller Reader Expander Dialer’s Earth Ground Connection Input Expander Power Supply Output Expander AC Mains Wiring Earth Ground Link Connection PRT-IVO-IF | Protege Inovonics Wireless Receiver Module | Installation Manual...
Page 8
Sector or Building #3 Note that the DIN rail enclosure earth terminal is connected to the power supply V- terminal. There must be only one single earth grounding point per system. PRT-IVO-IF | Protege Inovonics Wireless Receiver Module | Installation Manual...
For best results, mount transmitters and repeaters so they achieve line of sight with the repeaters and/or the receiver. This usually means they should be mounted as high as possible. PRT-IVO-IF | Protege Inovonics Wireless Receiver Module | Installation Manual...
Configuring the Inovonics Frequency Jumper This section applies only to the NA / AUS / NZ variant of the Inovonics receiver module (PRT-IVO-IF). The Inovonics EchoStream Receiver can use a range of radio frequencies and must be configured based on your geographic area using the frequency jumper.
Configuring the Inovonics EchoStream Select Jumper This section applies only to the European variant of the Inovonics receiver module (PRT-IVO-IF-EU). If you are using Inovonics EchoStream Select products in your system, you need to enable EchoStream Select compatibility on this device using the ES jumper.
The 12V N+ and N- communication input must be supplied from only one point. Connections from more than one 12V supply may cause failure or damage to the unit or the device supplying network power. PRT-IVO-IF | Protege Inovonics Wireless Receiver Module | Installation Manual...
RS-485 network. These are the modules physically located at the ends of the RS-485 network cabling. First Module on RS-485 Network Last Module on RS-485 Network 330R 330R From Next Previous Module Module PRT-IVO-IF | Protege Inovonics Wireless Receiver Module | Installation Manual...
Relay Output The receiver module has one onboard Form C relay output. The connection example shows the control of an external LED indicator. +12V AUX 1K5 OH PRT-IVO-IF | Protege Inovonics Wireless Receiver Module | Installation Manual...
Installing the module on an active network requires knowledge of the configuration and structure for the network. Always consult the network or system administrator and ask them to provide you with a fixed IP address that can be assigned to the module. PRT-IVO-IF | Protege Inovonics Wireless Receiver Module | Installation Manual...
If you don't know the IP address you can set it back to the default address of 192.168.1.3 Locate the default jumper next to the ethernet port on the PRT-IVO-IF side of the board. The jumper should be in the normal operating position on the two pins closest to the edge of the board.
UDP Resolved IP/Host: If a dynamic connection is used, you can confirm the controller's IP address by viewing ⦁ this field. UDP Port: The UDP port defines the port the expander uses to connect to the controller. This must match the ⦁ controller. PRT-IVO-IF | Protege Inovonics Wireless Receiver Module | Installation Manual...
To edit a user, click on the appropriate checkbox, then click Edit. This opens a new page where the user settings can be changed. For security reasons, we recommend you change the password of the admin user before deployment. PRT-IVO-IF | Protege Inovonics Wireless Receiver Module | Installation Manual...
Navigate to Wizards | Expanders Wizards. At the bottom of the Setup Wizard screen, click Step 2 - Auto Detection. The Inovonics (PRT-IVO-IF) module will come online and register as a reader expander. Rename the automatically assigned module name to Inovonics Module.
Click Save and download the changes to the controller. Inputs Table (PRT-IVO-IF) This section applies only to the NA / AUS / NZ variant of the Inovonics Receiver Module (PRT-IVO-IF). Refer to the table below to correctly program the specific button/input that will trigger the input operation.
Page 21
High Traffic Four Element Motion Detector EN1261HT Sensor Low Battery Tamper Inovonics PIR EN1260 Sensor Low Battery Tamper Pet Immune PIR EN1262 Sensor Low Battery Tamper Ceiling Mount PIR EN1265 Sensor Low Battery PRT-IVO-IF | Protege Inovonics Wireless Receiver Module | Installation Manual...
Inputs Table (PRT-IVO-IF-EU) This section applies only to the European variant of the Inovonics Receiver Module (PRT-IVO-IF-EU). Refer to the table below to correctly program the specific button/input that will trigger the input operation. Product Input Physical Alarm Wireless Transmitter...
Creating a Door Type and Linking to Credential Type and Door Navigate to Programming | Door Types and create a new door type, e.g. Inovonics Credential. Set the Entry Reading Mode to Custom. PRT-IVO-IF | Protege Inovonics Wireless Receiver Module | Installation Manual...
Click Add and select the Inovonics Access Level to be assigned to the user, then click OK. Click Save. Remember to download the above settings to the controller before testing. PRT-IVO-IF | Protege Inovonics Wireless Receiver Module | Installation Manual...
The serial number in the device is not valid. Return the unit to the distributor for replacement. Locked Device The module or system controller is a locked device and cannot communicate on the network. Return the unit to the distributor for replacement. PRT-IVO-IF | Protege Inovonics Wireless Receiver Module | Installation Manual...
Integrated Control Technology continually strives to increase the performance of its products. As a result these specifications may change without notice. We recommend consulting our website (www.ict.co) for the latest documentation and product information.
New Zealand and Australia General Product Statement The RCM compliance label indicates that the supplier of the device asserts that it complies with all applicable standards. PRT-IVO-IF | Protege Inovonics Wireless Receiver Module | Installation Manual...
This symbol is only valid in the European Union. If you wish to discard this product please contact your local authorities or dealer and ask for the correct method of disposal. PRT-IVO-IF | Protege Inovonics Wireless Receiver Module | Installation Manual...
NOTE: THE GRANTEE IS NOT RESPONSIBLE FOR ANY CHANGES OR MODIFICATIONS NOT EXPRESSLY APPROVED BY THE PARTY RESPONSIBLE FOR COMPLIANCE. SUCH MODIFICATIONS COULD VOID THE USER’S AUTHORITY TO OPERATE THE EQUIPMENT. PRT-IVO-IF | Protege Inovonics Wireless Receiver Module | Installation Manual...
Industry Canada Statement ICES-003 This is a Class A digital device that meets all requirements of the Canadian Interference Causing Equipment Regulations. CAN ICES-3 (A)/NMB-3 (A) PRT-IVO-IF | Protege Inovonics Wireless Receiver Module | Installation Manual...
Integrated Control Technology Ltd nor its employees shall be liable under any circumstances to any party in respect of decisions or actions they may make as a result of using this information. In accordance with the ICT policy of enhanced development, design and specifications are subject to change without notice.
Page 34
In accordance with the ICT policy of enhanced development, design and specifications are subject to change without notice.
Need help?
Do you have a question about the PRT-IVO-IF and is the answer not in the manual?
Questions and answers