Sign In
Upload
Download
Table of Contents
Contents
Add to my manuals
Delete from my manuals
Share
URL of this page:
HTML Link:
Bookmark this page
Add
Manual will be automatically added to "My Manuals"
Print this page
×
Bookmark added
×
Added to my manuals
Manuals
Brands
Kone Manuals
Controller
Board 1O4
Product instruction
Kone Board 1O4 Product Instruction
Door control board
Hide thumbs
1
2
Table Of Contents
3
4
5
6
7
8
9
10
11
12
13
14
15
16
page
of
16
Go
/
16
Contents
Table of Contents
Bookmarks
Table of Contents
Table of Contents
Equipment Description
Features of Door Operators with Board 1Ø4
Input & Output Terminals
Installing Door Operator Control Board 1Ø4
Adjusting Door Operator Control Board 1Ø4
Measure Current (Optional)
Set Potentiometers
Adjust Door Speeds
Adjust Door Closing Force
Adjust Nudge Speed
Set Microswitch Cams
Advertisement
Quick Links
1
Table of Contents
2
Equipment Description
3
Input & Output Terminals
4
Adjusting Door Operator Control Board 1Ø4
Download this manual
Product Instruction
Door Control Board:
®
Board 1Ø4
for PM/SSC
61111-149
(R3) 2000-08-31
Table of
Contents
Previous
Page
Next
Page
1
2
3
4
5
Advertisement
Table of Contents
Need help?
Do you have a question about the Board 1O4 and is the answer not in the manual?
Ask a question
Questions and answers
Summary of Contents for Kone Board 1O4
Page 1
Product Instruction Door Control Board: ® Board 1Ø4 for PM/SSC 61111-149 (R3) 2000-08-31...
Page 2
The right to make changes to product design and material use, without notice, is reserved. All hardware and software referenced in this publication and/or used in conjunction with equipment described herein is the exclusive property of Laws. KONE Inc. whether or not protected by U.S. and/or International Trademark, Copyright and/or Patent © 2000 KONE Inc. 61111-149 All rights reserved.
Page 3: Table Of Contents
Adjust nudge speed ......13 Set microswitch cams ......14 © 2000 KONE Inc. 61111-149 All rights reserved.
Page 4: Equipment Description
Acceleration & deceleration. Door operator control has an internal soft-start circuit which regulates smooth acceleration and deceleration. Soft-start circuit allows average motor voltage to change ® gradually when speeds change. Board 1Ø4 © 2000 KONE Inc. 61111-149 All rights reserved. (R3) 2000-08-31...
Page 5: Input & Output Terminals
Designates a Form “C” contact on 1-O relay. Relay is energized at all other times. DSD to SS Optional - Used on some projects for load balancing or other customer requirement. F615-SI1 (3/97) © 2000 KONE Inc. 61111-149 All rights reserved. (R3) 2000-08-31...
Page 6: Installing Door Operator Control Board 1Ø4
13. Connect transformer primary wires L2AX and L1A terminals of TB3. ➤ Multiple terminals are furnished for connecting to HPM/SSC power supplies. 149-003 (9/2000) © 2000 KONE Inc. 61111-149 All rights reserved. (R3) 2000-08-31...
Page 7
® Door Control Board: Board 1Ø4 for PM/SSC Product Instruction © 2000 KONE Inc. 61111-149 All rights reserved. (R3) 2000-08-31...
Page 8: Adjusting Door Operator Control Board 1Ø4
➤ O-OFF-C. O-OFF-C switch is normally in OFF (center) position. OFF position does not indicate input power has been removed. It only indicates no signal to open or close when TEST-RUN switch is in TEST position. A604-SI5 (2/97) © 2000 KONE Inc. 61111-149 All rights reserved. (R3) 2000-08-31...
Page 9: Measure Current (Optional)
2. Set voltmeter to a low range — 1 volt or 2.5 volt. 3. Read measurement with following in mind. ➤ 1 volt on meter indicates 10 amps of current. ➤ .5 volt on meter indicates 5 amps of current. A604-018 (2/97) © 2000 KONE Inc. 61111-149 All rights reserved. (R3) 2000-08-31...
Page 10: Adjust Door Speeds
TIP: If doors do not operate smoothly, particularly on slower moving doors, it may help to remove jumper J3. This eliminates dynamic braking, and allows a smoother transition between speeds. A604-SI6 (2/97) © 2000 KONE Inc. 61111-149 All rights reserved. (R3) 2000-08-31...
Page 11
® Door Control Board: Board 1Ø4 for PM/SSC Product Instruction Board 1 Ø ® © 2000 KONE Inc. 61111-149 All rights reserved. (R3) 2000-08-31...
Page 12: Adjust Door Closing Force
Code. If door closing force CANNOT be kept under 30 pounds, contact the door 5. To check door pressure, physically stall door at factory. midpoint in closing direction. A604-021 (9/2000) © 2000 KONE Inc. 61111-149 All rights reserved. (R3) 2000-08-31...
Page 13: Adjust Nudge Speed
TEST-RUN switch to RUN. F615-010 (2/97) When all adjustments are complete, place O-OFF-C switch in OFF position, and TEST-RUN switch in RUN position. Replace door operator cover. A604-SI7 (2/97) © 2000 KONE Inc. 61111-149 All rights reserved. (R3) 2000-08-31...
Page 14: Set Microswitch Cams
CAM drops OSDL microswitch when [10.2 to 15.2 mm] from fully closed position doors are approximately half open. when used with load balancing. CAM can also be set for other customer requirements. F615-009 (2/97) © 2000 KONE Inc. 61111-149 All rights reserved. (R3) 2000-08-31...
Page 15
® Door Control Board: Board 1Ø4 for PM/SSC Product Instruction Door in closed position Door in open position © 2000 KONE Inc. 61111-149 All rights reserved. (R3) 2000-08-31...
Page 16
® Door Control Board: Board 1Ø4 for PM/SSC Product Instruction NOTES © 2000 KONE Inc. 61111-149 All rights reserved. (R3) 2000-08-31...
Table of Contents
Print
Rename the bookmark
Delete bookmark?
Delete from my manuals?
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL
Need help?
Do you have a question about the Board 1O4 and is the answer not in the manual?
Questions and answers