Page 1
NOTICE is used to address practices not related to physical injury. Please be certain that the person who installs or uses this appliance carefully reads and understands the Safety Instructions contained in this manual. www.insinkerator.com/foodservice Part No. 15332 Rev. B...
The warranty includes parts and labor, provided the service is performed by an InSinkErator Factory Authorized Service Center. This warranty does not apply if failure is due to: faulty or improper electrical installation, faulty or improper plumbing installation, product abuse or misuse, or accidental damage.
US listed for use ® Use the flanges at the back of the control center with InSinkErator Foodservice Disposers. See Table 1 enclosure and only mount panel in the upright vertical for approved disposer and control center combinations position (door hinge is on the left). See Figure 1.
Plumbing Connections Figure 2. Typical Installation Diagram PLUMBING CONNECTIONS The flow control valve, syphon breaker and solenoid valve are supplied with all complete disposer packages (packed separately). Make certain that the solenoid valve supplied is the proper voltage. Make certain that the valves are plumbed according to water flow direction arrows marked on valves or the valves will not function properly.
Electrical Connections/Time Delay Relay ELECTRIC SHOCK PROPERTY DAMAGE • Turn off the electrical supply to the disposer before • Ensure that control center voltage and phase attempting any work on it. Use a voltmeter or match the disposer motor and electrical supply. circuit tester to ensure that power is off.
If trouble still persists, call your nearest In case of trouble, check the items listed below InSinkErator Authorized Service Agency. A. Disposer motor will not start and water For the location of your nearest service does not flow.
• Black wires = Line voltage (208 - 240 V) control. CC-202D-5 120 V 1-phase 1/2 to 2 HP Call Toll Free 1-800-845-8345 for the nearest InSinkErator Authorized Service Agency or to reach Technical Support.
• Black wires = Line voltage (208 - 240 V) control. CC-202D-6 208/240 V 1-phase 1/2 to 2 HP Call Toll Free 1-800-845-8345 for the nearest InSinkErator Authorized Service Agency or to reach Technical Support.
• Black wires = Line voltage (208 - 240 V) control. CC-202D-7 208/240 V 3-phase 1/2 to 10 HP Call Toll Free 1-800-845-8345 for the nearest InSinkErator Authorized Service Agency or to reach Technical Support.
• Black wires = Line voltage (380 - 460 V) control. CC-202D-8 380/460 V 3-phase 1/2 to 10 HP Call Toll Free 1-800-845-8345 for the nearest InSinkErator Authorized Service Agency or to reach Technical Support.