Advanced Configuration; Typical Set Up (Quick Start); Getting Status; Exiting The Program - Carrier WIRELESS TRANSCEIVER 33CNOAANT1 Installation And Service Instructions Manual

Wireless transceiver
Table of Contents

Advertisement

Fig. 6 — Host to Broadcast Set Up
Fig. 7 — Transceiver 2 Configuration
k. Repeat as necessary for more transceivers.
l. Check Report Generation.
m. Click Close.
n. Click Cancel.
o. Select Exit from the file menu.
6. View the report.
a. Open Windows Explorer.
b. Once in Windows Explorer, Open the following
file: C:\Program Files\Configuration Manager\
RReport.txt.
7. Test Operation.
Connect transceiver no. 1 to the host PC. Connect trans-
ceiver no. 2 to the loopback connector. Ensure all
transceivers have power and have antennas properly con-
nected. Run the loopback test in the Unit Testing section
of this manual. Repeat with the host and each remote unit.

ADVANCED CONFIGURATION

The Configuration Manager is used to configure all trans-
ceivers being used in the network. The procedures in this sec-
tion describe how to configure the transceiver to meet your
specific needs. This section should be used in conjunction with
the Typical Set Ups (Quick Start) section. See Fig. 8.
To open your Configuration Management application:
1. From the Start menu in Windows, select Programs and
then Configuration Manager.
A splash screen appears with a Login dialog on top re-
questing username and password.
2. Enter the username: "oem"
3. Enter the password: "oem"
NOTE: "oem" is lower case.
4. Click OK. The Main Window appears. A Tip of The Day
window also appears. A new tip of the day will appear
each time you open the configuration program. You can
turn this off by unchecking the box. Click OK to dismiss
the window.
Getting Status —
the status of the control lines on the RS-232 link between the PC
and the transceiver being configured. See Fig. 9 and Table 3.
In addition to the status lights in the Configuration Manager,
the LED's on the stand-alone transceiver also display status.
See Fig. 10.
Exiting the Program —
tion Manager, refer to the following.
Select Exit from the File menu.
NOTE: It is important to note that any changes in any tab not
stored in EEPROM will be lost.
Table 3 — Status Definitions
ABBREVIATION
RI
DCD
Data Carrier Detect
DTR
RTS
CTS
DSR
7
Status lights on the Status bar indicate
In order to exit the Configura-
NAME
DEFINITION
A signal is coming
into the host unit
Ring Indicator
from the transceiver
at the remote unit.
A connection has
been established
with another unit.
This lets the PC
know that communi-
cation between two
units can take place.
Indicates that the
unit is in Command
Data Terminal
Mode. This mode is
Ready
utilized by the net-
work software.
This is a hardware
Ready To Send
flow control indicator
A hardware control
Clear To Send
indicator
Reserved for future
Data Set Ready
use

Advertisement

Table of Contents
loading

This manual is also suitable for:

33cnsngmod33cnwirmod

Table of Contents