Labom PL110 Series Operating Instructions

Labom PL110 Series Operating Instructions

Electronic angle-of-rotation sensor 81.4

Advertisement

Quick Links

Operating Instructions
1 General Information....................................................................................................... 2
1.1 General Safety Notes .............................................................................................. 2
1.2 Intended Use ........................................................................................................... 2
1.3 Conformity with EU Regulations .............................................................................. 2
1.4 EX Approval ............................................................................................................ 2
2 Transportation and Storage .......................................................................................... 2
3 Installation and Commissioning .................................................................................. 2
3.1 Mechanical Installation ............................................................................................ 3
3.2 Electrical Connection .............................................................................................. 3
4 Operation ........................................................................................................................ 3
4.1 Zero-point setting .................................................................................................... 3
4.2 Maintenance / Service ............................................................................................. 4
5 Disassembly ................................................................................................................... 5
LABOM Mess- und Regeltechnik GmbH Im Gewerbepark 13 27798 Hude Germany
Hotline: +49 4408 804-444 Fax: +49 4408 804-100 e-mail: sales@labom.com www.labom.com
Electronic angle-of-rotation sensor 81.4
Type series PL110x
BA_057_en_2022-03_11.00
Page 1/5

Advertisement

loading

Summary of Contents for Labom PL110 Series

  • Page 1 4.1 Zero-point setting ....................3 4.2 Maintenance / Service ..................... 4 5 Disassembly ........................5 LABOM Mess- und Regeltechnik GmbH Im Gewerbepark 13 27798 Hude Germany BA_057_en_2022-03_11.00 Hotline: +49 4408 804-444 Fax: +49 4408 804-100 e-mail: sales@labom.com www.labom.com Page 1/5...
  • Page 2 In addition to this instruction, be sure to observe all statutory requirements, applica- ble standards, the additional technical specifications on the accompanying data sheet (see www.labom.com) as well as the specifications indicated on the type plate. General Safety Notes The installation, set up, service or disassembly of this device must only be done by trained, qualified personnel using suitable equipment and authorized to do so.
  • Page 3 Mechanical Installation Please pay attention to the measuring device operating instructions. If the device is opened there is a risk of influencing the signals by touching the electronic connections. This can be avoided by switching off the supply voltage or disconnecting the signal circuit.
  • Page 4 (see figure 1). You can find further information about zero- adjustment of pressure gauge with micro adjustment pointer in the document TA_029 on www.labom.com. Figure 1: Zero-point correction 4.1.2 Adjusting the angle-of-rotation sensor For adjustable devices the adjustment re-...
  • Page 5 Disassembly When measuring hot media, make sure that the device has cooled down prior to any dis- mounting or wear appropriate protective clothing to avoid burns. Switch off the power supply to the device before disconnecting the electrical connections. Once this is done, the device may be mechanically removed. Warning Opening pressurized lines might cause severe injuries.