Summary of Contents for Belanger Chameleon Arch Series
Page 1
Chameleon® Arch Series ® Chameleon ® Arch Series 1MANUAL526 Rev02...
Page 3
Do not make additional copies of this manual or electronically transmit it in any form ® whatsoever, in whole or in part, without the prior written permission of Belanger, Inc. The registered trademarks used in this document are the property of their respective owners. The use of such trademarks is ®...
Page 5
Updated Front Cover, Back Cover and Belanger Logo Updated Limited Warranty 3 & 8 Changed Bi-Flouride to Bi-fluoride ® Updated Description of Chameleon Arch added images Belanger, Inc. * PO BOX 5470 * Northville, MI 48167-5470 * Ph (248) 349-7010 * Fax (248) 380-9681 1MANUL526...
1976 Copyright Act. Belanger reserves the right to ® change or modify the Belanger, Inc. Limited warranty without notice. Belanger, Inc. * PO BOX 5470 * Northville, MI 48167-5470 * Ph (248) 349-7010 * Fax (248) 380-9681 1MANUL526...
!!IMPORTANT!! Important information that has more impact than a note-not related to injury. NOTE: General and/or helpful information-not related to injury or damage. Helpful tips. Belanger, Inc. * PO BOX 5470 * Northville, MI 48167-5470 * Ph (248) 349-7010 * Fax (248) 380-9681 1MANUL526...
Page 11
VIBRATE LOOSE DURING SHIPPING. CAUTION – BE AWARE OF HAZARDS ASSOCIATED WITH EQUIPMENT INSTALLED ON THE FLOOR THAT MAY BE A TRIP HAZARD. Belanger, Inc. * PO BOX 5470 * Northville, MI 48167-5470 * Ph (248) 349-7010 * Fax (248) 380-9681 1MANUL526...
Page 12
PRESSURE TO BELANGER® SPECIFIED EQUIPMENT. FIELD SUPPLIED PNEUMATIC TUBING MUST HAVE A MINIMUM OF 2 TIMES THE BURST STRENGTH OF SYSTEM PRESSURE. Belanger, Inc. * PO BOX 5470 * Northville, MI 48167-5470 * Ph (248) 349-7010 * Fax (248) 380-9681 1MANUL526...
Page 13
DO NOT USE TABLES, CHAIRS, OR OTHER NON-APPROVED CLIMBING EQUIPMENT OTHER THAN AS STATED HEREIN. CAUTION – ALWAYS WEAR SAFETY GLASSES WHEN PERFORMING MAINTENANCE ON ANY EQUIPMENT. Belanger, Inc. * PO BOX 5470 * Northville, MI 48167-5470 * Ph (248) 349-7010 * Fax (248) 380-9681 1MANUL526...
MSDS (Material Safety Data Sheet) should be obtained from the chemical supplier before using any chemical formulation. Belanger, Inc. * PO BOX 5470 * Northville, MI 48167-5470 * Ph (248) 349-7010 * Fax (248) 380-9681 1MANUL526...
Instruct personnel not to work on wash unless the entrance is blocked from vehicles entering, this is in addition to all other safety precautions. Belanger, Inc. * PO BOX 5470 * Northville, MI 48167-5470 * Ph (248) 349-7010 * Fax (248) 380-9681 1MANUL526...
Periodically check all system stop circuits are functional. Table 1 Recommended General Practices to Do and Not Do when Installing, Maintaining, and/or Servicing Belanger® Equipment. Belanger, Inc. * PO BOX 5470 * Northville, MI 48167-5470 * Ph (248) 349-7010 * Fax (248) 380-9681 1MANUL526...
The feeds are in the center of the arch for optimum and balanced flow. Belanger, Inc. * PO BOX 5470 * Northville, MI 48167-5470 * Ph (248) 349-7010 * Fax (248) 380-9681 1MANUL526...
PRESSURE TO BELANGER® SPECIFIED EQUIPMENT. FIELD SUPPLIED PNEUMATIC TUBING MUST HAVE A MINIMUM OF 2 TIMES THE BURST STRENGTH OF SYSTEM PRESSURE. Belanger, Inc. * PO BOX 5470 * Northville, MI 48167-5470 * Ph (248) 349-7010 * Fax (248) 380-9681 1MANUL526...
103-1/2” the various (2.63 m) available pendant options. 125” (3.18 m) Above images show the Spray Arch Belanger, Inc. * PO BOX 5470 * Northville, MI 48167-5470 * Ph (248) 349-7010 * Fax (248) 380-9681 1MANUL526...
4) Locate the leg weldments and secure one leg to each head beam weldment as shown in the image below. Both leg weldments are identical and can be used on either side. Belanger, Inc. * PO BOX 5470 * Northville, MI 48167-5470 * Ph (248) 349-7010 * Fax (248) 380-9681 1MANUL526...
Page 24
7) Spray Arch Only: Remove the top spray manifold assembly from the skid. It should have the nozzle extensions and the barbed hose fittings already in place. Barbed Hose Fitting (2) Nozzle Extension (4) Belanger, Inc. * PO BOX 5470 * Northville, MI 48167-5470 * Ph (248) 349-7010 * Fax (248) 380-9681 1MANUL526...
Page 25
10) Spray Arch Only: Insert the Arch top spray manifold assembly into the long head beam weldment as shown in the image. Before After Belanger, Inc. * PO BOX 5470 * Northville, MI 48167-5470 * Ph (248) 349-7010 * Fax (248) 380-9681 1MANUL526...
Page 26
12) Spray Arch Only: Apply Teflon tape and liquid Teflon to the threads of the nipple and tighten the supplied 1/2” (12.7 mm) coupling to the top spray manifold. Before After Belanger, Inc. * PO BOX 5470 * Northville, MI 48167-5470 * Ph (248) 349-7010 * Fax (248) 380-9681 1MANUL526...
Spray Arch Only: Slide the two remaining ear clamps over the ends of the blue water hose and secure the hose to the side spray manifolds. Before After Belanger, Inc. * PO BOX 5470 * Northville, MI 48167-5470 * Ph (248) 349-7010 * Fax (248) 380-9681 1MANUL526...
Page 28
6) Spray Arch Only: Locate the remaining filler strips and place them into their proper location as shown in the image below. Belanger, Inc. * PO BOX 5470 * Northville, MI 48167-5470 * Ph (248) 349-7010 * Fax (248) 380-9681 1MANUL526...
Use the image below for more detail. Note: Above image shows the Oval Pendant Belanger, Inc. * PO BOX 5470 * Northville, MI 48167-5470 * Ph (248) 349-7010 * Fax (248) 380-9681 1MANUL526...
Page 30
CAN OCCUR IF THE RADIUS IS TOO TIGHT. Be sure that the neon strips are pressed firmly into the face of the pendant Belanger, Inc. * PO BOX 5470 * Northville, MI 48167-5470 * Ph (248) 349-7010 * Fax (248) 380-9681 1MANUL526...
Page 31
As stated before, the 7 configuration is for a scenario whereas the neon strips extend beyond the hole patterns. See the image below for details. Belanger, Inc. * PO BOX 5470 * Northville, MI 48167-5470 * Ph (248) 349-7010 * Fax (248) 380-9681 1MANUL526...
Page 32
Refer to the wiring images for proper electrical hookups. Belanger, Inc. * PO BOX 5470 * Northville, MI 48167-5470 * Ph (248) 349-7010 * Fax (248) 380-9681 1MANUL526...
Page 33
Flasher White lead from Controller to white wire of Flasher Black lead from Controller to black wire of Flasher Belanger, Inc. * PO BOX 5470 * Northville, MI 48167-5470 * Ph (248) 349-7010 * Fax (248) 380-9681 1MANUL526...
Page 34
15) Refer to the wiring images for proper electrical hookups. Be sure to create a “loop” in the wire so that no water can run into the electrical box as shown below. Looped wire Belanger, Inc. * PO BOX 5470 * Northville, MI 48167-5470 * Ph (248) 349-7010 * Fax (248) 380-9681 1MANUL526...
3/4” (19.1 mm) water hose(s) to the barbed hose fitting(s) as shown below. Belanger, Inc. * PO BOX 5470 * Northville, MI 48167-5470 * Ph (248) 349-7010 * Fax (248) 380-9681 1MANUL526...
2) Use the supplied flat washers and hairpin clips to secure the back section of the pendant cover as shown below. Before After Above image shows Oval Pendant. Note: Belanger, Inc. * PO BOX 5470 * Northville, MI 48167-5470 * Ph (248) 349-7010 * Fax (248) 380-9681 1MANUL526...
Utility Arch Utility Arch: Mount the Adapter Kit channel so it wraps around the exit side of the arch as shown below. Belanger, Inc. * PO BOX 5470 * Northville, MI 48167-5470 * Ph (248) 349-7010 * Fax (248) 380-9681 1MANUL526...
Page 38
5) Once the sign mount weldment is mounted onto the arch simply place the swivel nipple into the coupling on the sign mount weldment and tighten the sign down to the desired angle. Belanger, Inc. * PO BOX 5470 * Northville, MI 48167-5470 * Ph (248) 349-7010 * Fax (248) 380-9681 1MANUL526...
The image above shows the Triple Foaming Foaming Pods. The Single Foaming Pods mount the same way. Above images show Sunburst Pendant. Note: Belanger, Inc. * PO BOX 5470 * Northville, MI 48167-5470 * Ph (248) 349-7010 * Fax (248) 380-9681 1MANUL526...
Page 40
2) Remove the two pieces of angle that the foam pods will mount to and the button head fasteners from the accessory box. Mount the angles to each leg as shown in the images below. Before After Belanger, Inc. * PO BOX 5470 * Northville, MI 48167-5470 * Ph (248) 349-7010 * Fax (248) 380-9681 1MANUL526...
Page 41
If you are hooking up triple foam pods, you will have been shipped an aluminum manifold assembly. Tee/Elbow Assemblies Aluminum Manifold Assembly Belanger, Inc. * PO BOX 5470 * Northville, MI 48167-5470 * Ph (248) 349-7010 * Fax (248) 380-9681 1MANUL526...
Page 42
You will use two of the sections at each corner of the head beam. The third will be used at the point where the airlines will come out of the filler strip at the upper portion of each leg. Belanger, Inc. * PO BOX 5470 * Northville, MI 48167-5470 * Ph (248) 349-7010 * Fax (248) 380-9681 1MANUL526...
Page 43
Arch leg weldments. When positioning these sections, be sure the slotted holes are toward the bottom end of the filler strips. Belanger, Inc. * PO BOX 5470 * Northville, MI 48167-5470 * Ph (248) 349-7010 * Fax (248) 380-9681 1MANUL526...
Page 44
Make sure that the nylon protective sleeve is positioned so that it is not allowing the airlines to rub any of the edges at the slotted area of the filler strip. Belanger, Inc. * PO BOX 5470 * Northville, MI 48167-5470 * Ph (248) 349-7010 * Fax (248) 380-9681 1MANUL526...
Page 45
If possible, test with a few different vehicles that vary in height and width. This will allow you to get a better judgment on how to maximize the coverage for various vehicles. Belanger, Inc. * PO BOX 5470 * Northville, MI 48167-5470 * Ph (248) 349-7010 * Fax (248) 380-9681 1MANUL526...
Page 46
4) Mount the foam pod angle to the foam pod cross brace using the two, 3/8-16 button head fasteners. Tighten the fasteners down. Before After Belanger, Inc. * PO BOX 5470 * Northville, MI 48167-5470 * Ph (248) 349-7010 * Fax (248) 380-9681 1MANUL526...
Page 47
1/2” to 3/8” (12.7 to 9.52 mm) union reducers. There are two different scenarios that can be hooked up to the foam pods. The following will explain in better detail. 3-Way Dividers Union Reducers Belanger, Inc. * PO BOX 5470 * Northville, MI 48167-5470 * Ph (248) 349-7010 * Fax (248) 380-9681 1MANUL526...
Page 48
Use the images below for routing the 1/4” (6.35 mm) airlines to the center foam pod assembly. Belanger, Inc. * PO BOX 5470 * Northville, MI 48167-5470 * Ph (248) 349-7010 * Fax (248) 380-9681 1MANUL526...
1) Locate the box that the Rain Arch components shipped in and confirm that all of the pieces are there and also that there is no damage to any of the components. 8379 Shim Plates 8380 Belanger, Inc. * PO BOX 5470 * Northville, MI 48167-5470 * Ph (248) 349-7010 * Fax (248) 380-9681 1MANUL526...
Page 50
Rain Arch bar weldment. Note: Be sure to install the hose fitting on the utility room side of the manifold. Belanger, Inc. * PO BOX 5470 * Northville, MI 48167-5470 * Ph (248) 349-7010 * Fax (248) 380-9681 1MANUL526...
Page 51
At this point you can refer to the supplied Rain Arch manual for the initial startup instructions and the maintenance procedures. Belanger, Inc. * PO BOX 5470 * Northville, MI 48167-5470 * Ph (248) 349-7010 * Fax (248) 380-9681 1MANUL526...
(shown in dotted ovals below) face away from the center of the bay. After Before Belanger, Inc. * PO BOX 5470 * Northville, MI 48167-5470 * Ph (248) 349-7010 * Fax (248) 380-9681 1MANUL526...
Page 53
8) Place the nozzle caps with nozzles onto each of the nozzle bodies and snap them in to place as shown in the images. Belanger, Inc. * PO BOX 5470 * Northville, MI 48167-5470 * Ph (248) 349-7010 * Fax (248) 380-9681 1MANUL526...
Page 54
10) Snap the driver side and passenger side spray manifold assemblies to their legs as shown in the images below. Before After Belanger, Inc. * PO BOX 5470 * Northville, MI 48167-5470 * Ph (248) 349-7010 * Fax (248) 380-9681 1MANUL526...
Page 55
Make sure that the nylon protective sleeve is positioned so that it is not allowing the airlines to rub any of the edges at the slotted area of the head beam corner. Belanger, Inc. * PO BOX 5470 * Northville, MI 48167-5470 * Ph (248) 349-7010 * Fax (248) 380-9681 1MANUL526...
Page 56
They will be used to run the airlines through. Run the lines through the slotted area and then snap the filler strip into place. Refer to the images on the next for more detail. Belanger, Inc. * PO BOX 5470 * Northville, MI 48167-5470 * Ph (248) 349-7010 * Fax (248) 380-9681 1MANUL526...
Page 57
Note: Be sure the slotted holes are positioned on the upper end of the filler strip. 19) Locate the third section of nylon protective sleeve and cut it in half. Belanger, Inc. * PO BOX 5470 * Northville, MI 48167-5470 * Ph (248) 349-7010 * Fax (248) 380-9681 1MANUL526...
Page 58
23) Turn on the main water and run it through the lines. Check to make sure that there are no leaks at any point on the system. Belanger, Inc. * PO BOX 5470 * Northville, MI 48167-5470 * Ph (248) 349-7010 * Fax (248) 380-9681 1MANUL526...
(shown in dotted ovals below) face away from the center of the bay. Before After Belanger, Inc. * PO BOX 5470 * Northville, MI 48167-5470 * Ph (248) 349-7010 * Fax (248) 380-9681 1MANUL526...
Page 60
9) Locate the accessory box and remove the six aluminum brackets that have the Snap Tight plastic clamps mounted to them and the 1/2” (12.7 mm) long self tapping screws. Belanger, Inc. * PO BOX 5470 * Northville, MI 48167-5470 * Ph (248) 349-7010 * Fax (248) 380-9681 1MANUL526...
Page 61
!!IMPORTANT!! DO NOT OVER TIGHTEN THE SELF TAPPING SCREWS! 11) Snap the all four side spray manifold assemblies to their legs as shown in the images below. Belanger, Inc. * PO BOX 5470 * Northville, MI 48167-5470 * Ph (248) 349-7010 * Fax (248) 380-9681 1MANUL526...
Page 62
15) Replace the rear cover of the pendant. Belanger, Inc. * PO BOX 5470 * Northville, MI 48167-5470 * Ph (248) 349-7010 * Fax (248) 380-9681 1MANUL526...
Page 63
They will be used to run the airlines through. Run the lines through the slotted area and then snap the filler strip into place. Refer to the images below for more detail. Belanger, Inc. * PO BOX 5470 * Northville, MI 48167-5470 * Ph (248) 349-7010 * Fax (248) 380-9681 1MANUL526...
Page 64
Note: Be sure the slotted holes are positioned on the upper end of the filler strip. 20) Locate the third section of nylon protective sleeve and cut it in half. Belanger, Inc. * PO BOX 5470 * Northville, MI 48167-5470 * Ph (248) 349-7010 * Fax (248) 380-9681 1MANUL526...
Page 65
24) Turn on the main water and run it through the lines. Check to make sure that there are no leaks at any point on the system. Belanger, Inc. * PO BOX 5470 * Northville, MI 48167-5470 * Ph (248) 349-7010 * Fax (248) 380-9681 1MANUL526...
4) Run water through the Arch and verify that there are no leaks at any of the fitting or nozzle locations. Note: Nozzle selection is dependant on application, Nozzles vary for High-Pressure, Reclaim, Pre-Soak, Waxes and R.O. Belanger, Inc. * PO BOX 5470 * Northville, MI 48167-5470 * Ph (248) 349-7010 * Fax (248) 380-9681 1MANUL526...
Remove any kinks from hose • • Inadequate water pressure Open water valve to fullest • Call Distributor for advice on installing booster pump Belanger, Inc. * PO BOX 5470 * Northville, MI 48167-5470 * Ph (248) 349-7010 * Fax (248) 380-9681 1MANUL526...
Continue rubbing down and applying light coats, until the edges of the damaged paint have disappeared. Applied properly, at this stage all physical signs of repair can be lost. Belanger, Inc. * PO BOX 5470 * Northville, MI 48167-5470 * Ph (248) 349-7010 * Fax (248) 380-9681 1MANUL526...
Page 72
It is always good practice to mechanically abrade a key by using rubbing down paper, or at least use a Scotchbrite. A small discrete area should be tested first. Belanger, Inc. * PO BOX 5470 * Northville, MI 48167-5470 * Ph (248) 349-7010 * Fax (248) 380-9681 1MANUL526...
Arch Head Beam Filler Strip 51-3/4” (1.31 m) 8404 Arch Head Beam Filler Strip 61-13/16” (1.57 m) 9395 Arch Head Beam Filler Strip 61-13/16” (1.57 m) Belanger, Inc. * PO BOX 5470 * Northville, MI 48167-5470 * Ph (248) 349-7010 * Fax (248) 380-9681 1MANUL526...
Total on assembly. 2501 1AIRLN165, Black, 12” (30.5 cm) 1WASHR-LC115 (6) 1FSTNR-SH059 (2) Total on assembly. Total on assembly. 1ELBOW-PL764 Flasher Box #105113 Belanger, Inc. * PO BOX 5470 * Northville, MI 48167-5470 * Ph (248) 349-7010 * Fax (248) 380-9681 1MANUL526...
ENVIRONMENTAL LAW – DO NOT DISPOSE OF BY ADDING TO THE MUNICIPAL WAST STREAM. METAL/OTHER PARTS OF THE SYSTEM: MUST BE RECYCLED AS REQUIRED BY LOCAL ENVIRONMENTAL LAW. Belanger, Inc. * PO BOX 5470 * Northville, MI 48167-5470 * Ph (248) 349-7010 * Fax (248) 380-9681 1MANUL526...