LG RT-29FB50RB Service Manual page 12

Hide thumbs Also See for RT-29FB50RB:
Table of Contents

Advertisement

ITEM
RANGE
50Hz
VA
0050~00CF
0083
VL
0025~00BF
00FD
7. SVC Data & PSM,SSM Data.
PICTURE SETTING DATA (LINE SVC-3)
Menu
DVCO(Digital VCO)
IBRM(BLACK CURRENT)
WDRM(WHITE CURRENT)
BCLT(BCL THERSHOLD
BCLTM(BCL TIME)
BCLGA(BCL GAIN)
SVGA(SVM GAIN)
SVDEL(SVM DELAY)
SVD1(SVM DELAY1)
LDLY(L DELAY)
DSCC(Discharge Sample)
DSCV(Vertical Discharge)
8. OPTION Adjustment (OPTION-1,2, 3,Teletext)
8-1. Preparation for Adjustment
1) This decides funtion in accordance with model.
Press the SVC TX adjustment button(IN-START button) at SVC mode,then adjust the option at OPTION 1,2,3,4 mode.
2) Mark the option adjustment data like [111,11,111,11] in BOM.
[113,63,112,128]
D
OPTION 1
OPTION 2
OPTION 3
OPTION 4
Mark of BOM
O
LEVEL
PART NO.
1.
3141VMN382A
The OPTION 1 data is 113,OPTION 2 data is 63,the oOPTION 3 data is 112,the OPTION 4 data is 128 in this model.
8-2. Adjustment Method
1) Input data directly by the buttons corresponded with OPTION1 ??(0~255), OPTION2 ??(0~255), OPTION3 ???(0~127),OPTION 4
???(0 ~255).
2) Select each OPTION function by the CH Up/Down button and then set up each OPTION by the VOL Up/Down button.
All manuals and user guides at all-guides.com
16: 9
14: 9
60Hz
50Hz
60Hz
0083
008F
008E
00FA
00FD
00A
Range
25/29" LG Flat 29" S/S-Flat
0~1FFH
00C8
0~3FFH
0190
0~7FFH
0055
0~1FFH
0007
0~1FFH
0007
000D
0007
0003
FFFC
0~01FF
000D
0~01FF
FB80
D D D
SPECIFICATION
MAIN[MC-022A]
- 12 -
ZOOM
STANDARD
50Hz
60Hz
50Hz
00A7
00A7
0083
00FD
00F8
00FD
25" FST
28" FST
00C8
00C8
00C8
0190
0190
0190
0055
0050
0050
0007
0007
0007
0007
0007
0007
000D
000D
000D
0007
0007
0007
0003
0003
0003
FFFE
FFFE
FFFE
000D
0009
FB80
FDC0
DESCRIPTION
JOB EXP.
CHASSIS ASSY