BLOOD SUGAR CONTROL SYSTEM
User Manual
TD-4277B version 2.0 2016/03
HT102015B-01G
311-4277200-002

Advertisement

Table of Contents
loading

Summary of Contents for TD GLUCO TD-4277B

  • Page 1 BLOOD SUGAR CONTROL SYSTEM User Manual TD-4277B version 2.0 2016/03 HT102015B-01G 311-4277200-002...
  • Page 2 Regularly checking your blood sugar levels can help both you and your doctor improve the control of your diabetes. Thanks to the small size and easy-to-use functions, you can use the TD-GLUCO Bluetooth blood sugar control system to easily measure your blood sugar levels, wherever and whenever you want.
  • Page 3: Table Of Contents

    IMPORTANT SAFETY INSTRUCTIONS INHOUD READ BEFORE USING BEFORE YOU START Important information 1. ONLY use the device for the purposes stated in this manual. Meter overview 2. Do not use ANY accessories not specified by the manufacturer. Display 3. Do NOT use the device if it is malfunctioning or damaged. Test strip 4.
  • Page 4: Before You Start

    BEFORE YOU START Important information • Extreme dehydration and excessive moisture-loss can lead to results being measured that are below the actual levels. If you suspect you are suffering from extreme hydration, contact your GP immediately. • If your blood sugar levels are lower or higher than normal and you are not displaying any symptoms of being ill, then repeat the test.
  • Page 5: Meter Overview

    Bluetooth indicator SET button (S) Input the meter settings and confirm them. NOTE: Battery compartment The TD-GLUCO Bluetooth meter may only be used with TD-GLUCO TD-4360 test strips. Using other test strips with this meter could produce inaccurate results.
  • Page 6: Setting Up The Meter

    SETTING UP THE METER When the hours/minutes are flashing, press M to select the hour/minutes. Then press S Before using your meter for the first time or whenever you replace the battery, and continue to the next reminder setting. check and adjust the following settings. PLEASE NOTE: Launching the setup mode (a) When the reminder notification goes off, press M to switch it off;...
  • Page 7: Quality Control Test

    QUALITY CONTROL TEST WARNING: This test using control solution is not required when first using the TD-GLUCO When you perform a test using control solution mark it as such so that the test result Bluetooth blood sugar control system. is NOT confused with the blood sugar TEST RESULTS in the device's memory. If you...
  • Page 8: Testing Using Blood Samples

    TESTING USING BLOOD SAMPLES WARNING: NOTE In order to limit the chance of an infection: • Every time you test, use a different puncture point. Repeatedly puncturing the • Never share a lancet or lancing device with others. same point can cause a sore to form and callousing. •...
  • Page 9: Meter Memory

    METER MEMORY NOTE: The meter stores the 1,000 most recent blood sugar test results together with their dates • Do not press the puncture point against the test strip and try not to smear the blood. and times. In order to access these records, start with the device turned off. •...
  • Page 10 Bluetooth® is activated before trying to transmit data. Also make sure that your Use "Search" to find your meter, which is called Ht One TD Gluco xxxx (xxxx = the meter and smartphone are sufficiently close together so that they can connect.
  • Page 11: Maintenance

    MAINTENANCE Caring for your meter Battery Cleaning the meter Your meter comes with two 1.5 V AAA alkaline batteries. • To clean the exterior of the meter, wipe it off with a cloth that has been lightly dampened with tap water or a mild detergent, then dry it using a soft and dry cloth. Low battery warning DO NOT rinse off with water.
  • Page 12: Important Information On The Control Solution

    TROUBLESHOOTING SYSTEM ISSUES • Use a test strip immediately after removing it from the tube. • On the label, write the date you first opened the tube. Dispose of any remaining test If you perform the recommended action but the issue continues, please call your local strips after 3 months.
  • Page 13: Troubleshooting

    DETAILED INFORMATION Troubleshooting other issues 1. The meter returns plasma-equivalent results: 1. If nothing is displayed on the meter after a test strip is inserted: POSSIBLE CAUSE ACTION Time of day Normal plasma glucose range for Batteries are drained. Replace the batteries. nondiabetics (mg/dL) The test strip has been inserted upside down Insert the part of the strip containing the...
  • Page 14: Specifications

    SPECIFICATIONS NOTES Model no.: TD-4277B --------------------------------------------------------------------------------------------------------------------------------------- Dimensions and weight: 96 (L) x 61(B) x 26 (H) mm, 67,2 g Power source: Two 1.5 V AAA alkaline batteries --------------------------------------------------------------------------------------------------------------------------------------- Display: LCD --------------------------------------------------------------------------------------------------------------------------------------- Memory: 1,000 test results with associated dates and times...