CHARGE FIRST! Before using your new Power Station T-1000 or after storing it for more than 3 months, plug it into a suitable wall outlet until it is fully charged.Then you can start your exciting journey with it.
Safety instructions Read the following instructions to ensure safety before using. Improper use may result in fire, property damage or personal injury. INSTRUCTIONS PERTAINING TO RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS IMPORTANT SAFETY INSTRUCTIONS WARNING - When using this product, basic precautions should always be followed, including the following: Read all the instructions before using the product.
2. Do not charge the unit via solar panel that operate voltage outside of DC12-26V. 3. Always use approved attachment charging cables. we take no responsibility for any damage caused by using other brand charging cable. 4. When charging, please place the product on the ground with no flammable or combustible materials around.
Photovoltaic input SOS Mode & LED light USB-A output Note: No user-serviceable parts inside. Recommended to fully charge the T-1000 before use. Button feature A: Power ON/OFF Button B: SOS mode & LED light Button C: DC Output ON/OFF Button...
E to shut down the output(s) when not in use. COOLING FAN T-1000 utilizes an internal cooling fan to ensure the product is operating within the appropriate temperature range. T-1000, when it experiences a higher output load, will automatically turn on the fan during discharge or recharging, the fan may operate intermittently to keep internal temperature within operating range.
What it powers Laptops (41.4Wh) 32" TV(60W) CPAP without heated Gopro (5.9Wh) Floodlight(4W) Around Around humidifier (15W) Around Around 19 Recharges 13 hours 53 hours 135 Recharges 200 hours +MORE DJ Drone(89.2Wh) Smartphone(10Wh) Switch(16Wh) Mini Fridge(40W) Around Around Around Around 8.9 Recharges 80 Recharges 50 Recharges...
Page 8
Function buttons It will take 7-8 hours to charge fully by using the AC adapter we provided. AC Outlet AC Adapter Solar panel charging 1. DO NOT charge the unit with solar panel that operate voltage outside of DC12-26V 2. Place solar panels in direct sunlight as much as possible. 3.
Recommended back to charge the T-1000 when battery indicate less than 20%. Note that when you first plug in a power source, whether it's a solar panel or a wall charger, the T-1000 may take a minute to detect and adjust its charge circuitry before it starts drawing power from the source.
Page 10
When it is charging, the LCD Screen will be illuminated, and the LCD display will provide Battery level Indicator, T-1000 is charged when the level is 100% and the current will get smaller and smaller until it is stop charging.
General specifications General specs Rated capacity 999Wh ≈8.2kg Weight (net weight) ≈9.8kg Weight (including accessories) Product size 294mm*202mm*202mm Input DC input 12-26V, max.155W AC 100-240V (50Hz/60Hz), DC 24V, 6.25A AC/DC adapter Solar charge input 12-26V, max.155W Car charger DC 12V, max.105W Output AC output voltage 110V/60Hz...
Equipment cleaning Please make sure that the device is disconnected from all input power and output devices, Wipe with a clean, dry, non-soft cotton cloth. Removing any foreign objects, dirt or other obstructions on the vents on both sides. When cleaning foreign objects in the side vents, do not allow debris, dirt or other Blockage enters the equipment.
Trouble shooting The power supply does not discharge: (1) Check whether the output buttons are activated; (2) Check whether the total output power exceeds the rated output power; (3) Check the battery power indicator to confirm whether the power supply is sufficient; (4) If the device cannot be discharged after it is discharged for longtime, please wait for several hours and try again, it may enter the over-temperature protection.
Warranty period The warranty period is 12 months, and the warranty period is calculated by the original consumer purchaser from the date of purchase. In order to determine the start date of the warranty period, a sales receipt from the first consumer purchase or other reasonable documentary proof is required.
Page 15
NOTE: A photovoltaic panel as an input for charging the internal battery shall be provided with an inverter and/or a charge controller in accordance with UL 1741 or UL 62109-1; The external power supply shall be a power source in accordance with the Standard UL 60950-1 and CAN/CSA C22.2 No.
Page 16
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.