Automatic timer / drain valves

Advertisement

PSB Model ET-4 NEMA 4 & ET-5 NEMA 4 - Automatic Timer/Drain Valves
Toggle Switch Settings – Switches Are Mounted On The Printed Circuit
Board, Under The Top Cover.
"X" indicates the switch is on.
Time Between Valve Openings
1
2
Hrs./Min.
:15
X
:30
X –Factory Setting
:45
X
X
1:00
1:15
X
1:30
X
1:45
X
X
2:00
2:15
X
2:30
X
2:45
X
X
3:00
3:15
X
3:30
X
3:45
X
X
Valve can be set for time between openings with any valve time open.
Power supply 120 volt single phase.
To change times, remove six socket head cap screws, lift off cover and reset
switches as required.
To check proper functioning of the printed circuit board and to manually operate
valve, press and release manual override on side of housing. Valve will open and
remain open for the set opening time. Valve will then close and timer will start a
new cycle.
If the manual override is pressed and valve does not turn, the circuit board may be
defective and should be replaced or repaired at the factory.
1202 West 12th Street, Erie, PA, USA 16501
SWITCH NUMBERS
3
4
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
PSB INDUSTRIES INC.
www.psbindustries.com
Phone: (814) 453-3651
Time Valve Is Open
Seconds
5
6
4.5
X
9.0
X—Factory Setting
13.5
X
X
18.0
22.5
X
27.0
X
31.5
X
X
36.0
40.5
X
45.0
X
49.5
X
X
54.9
58.5
X
63.0
X
67.5
X
X
P.O. Box 1318, Erie, PA, USA 16512-1318