STL MWS-Ex-DC Quick Start Manual

Microwave presence detector for zone 1/21

Advertisement

MICROWAVE PRESENCE DETECTOR
FOR ZONE 1/21
MWS-Ex-DC
1

Safety information and Notes

1.1
Storage of this manual
Keep this user manual safe and in the vicinity of the device. All persons who work on or with it should be advised on
where the manual is stored.
1.2
Special conditions of safe use
The rated temperature range is listed on the label and is more restricted than in the certificate.
1.3
List of notes
WARNING!
Installation to be by skilled electricians and instructed personnel in accordance with national
legislation, including the relevant standards and, where applicable, in accordance with IEC
79.17 on electrical apparatus for explosive atmospheres.
WARNING!
For the installation, maintenance and cleaning of the sensor, it is absolutely necessary to
observe the latest applicable regulations and provisions concerned with explosion protection
(EN60079-0, EN60079-14) as well as the Accident Prevention Regulations.
WARNING!
The sensor can be operated in ATEX Gas/Dust Zone 1/21 or Zone 2/22 hazardous area, or in
safe area. Refer to the ATEX certificates for further information.
WARNING!
The sensor must not be stored or operated outside of its rated temperature range as stated
on the ATEX certification label
WARNING!
The technical data indicated on the ATEX rating labels, this manual and the ATEX certificates
must be observed at all times.
STL Reference:
MWS-Ex-DC
Document: Installation and Operations Manual
Date:
July 2020
Revision:
IOM-MWS-iss0
P a g e
| 1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MWS-Ex-DC and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for STL MWS-Ex-DC

  • Page 1 MICROWAVE PRESENCE DETECTOR FOR ZONE 1/21 MWS-Ex-DC Safety information and Notes Storage of this manual Keep this user manual safe and in the vicinity of the device. All persons who work on or with it should be advised on where the manual is stored.
  • Page 2 A microprocessor then triggers the ON command. Detection is possible through doors, panels of glass and thin walls. Specification Type: MWS-Ex-DC (Housing CPST-26/EMH90) Ex rating: ATEX II 2GD / Ex db IIC T6 Gb / Ex tb IIC T85°C Db IP66 INERIS03ATEX0009X...
  • Page 3 A single sensor can trigger multiple pieces of equipment or luminaires. The output voltage is the same as the supply voltage. Connect ‘+’ and ‘–‘ to the drivers/ballasts of the grouped fittings for simultaneous switching. Settings and Functions STL Reference: Date: Revision: MWS-Ex-DC July 2020...
  • Page 4 If the daylight sensor is disabled, the sensor will only operate when movement is detected. (Daylight sensor disabled is the factory default – all switches ON) Contact STL International Ltd Hill Farm, Linton Hill Maidstone, Kent ME17 4AL United Kingdom...