1 channel RF Receiver 230Vac (EFHRFR 001)
MODES DESCRIPTION
-
Radio frequency RF receiver (433.92 Mhz).
-
Personal code on each product.
-
Equipped with a push
button to select AUTO, MANUAL or RF INIT
mode.
-
To be used only with ours thermostats.
Mode push button
AUTO Mode
Press
button
Manual Mode
(Heater forced)
Press
button
Manual Mode
(Stop forced)
Press
button
during 4sec
Press
button
RF init
Press
button
GB
RF LED.
Manual Mode LED.
(Green)
(Yellow)
Heating LED.
(Red)
RADIO CONFIGURATION MODE
1.
Install and plug the Receiver. Then press the Receiver push button
seconds, the Green LED should lit up indicating that the Receiver is now in radio
configuration mode waiting for a thermostat configuration address.
Please refer to the thermostat leaflet for enter the thermostat in "RF Init" mode.
2.
3.
Verify that radio signals are correctly received by the Receiver. On the Receiver,
the Green LED should blink at each radio signal received from the thermostat.
4.
Exit the Radio configuration mode on the thermostat. (Please refer to the
thermostat leaflet)
5.
Now starting up your installation in AUTO mode.
LED INDICATOR
Yellow
Red
Green
0
0
0
Automatic mode, HEATER stopped
0
1
0
Automatic mode,
1
0
0
Manual
1
1
0
Manuel
quick flash
0 or
1
0 or
1
Reception of an order,
0 or
1
0 or
1
1
Waiting for a
slow blink
0
0
ERROR see repair sequence bellow:
- Verify the emitter batteries.
- Verify the emitter/receiver range.
- No perturbation by an apparatus at less than 50cm of
Repair instructions
the receiver.
- No perturbation by an apparatus on the 433.92 MHz
frequency (continuous transmission).
By pressing on the push
- Verify that the receiver is correctly connected
button
- Verify main power supply (230VAC)
nothing happens
TECHNICAL CHARACTERISTICS
0°C - 50°C (or 32°F – 122°F)
Operating temperature
Electrical
Class II - IP44
Protection
Power Supply
230Vac 50Hz
433.92 MHz, <10mW.
Radio frequency and
Range of approximately 100m in open space.
Receiving zone
Range of approximately 30m in residential environment.
CE. EN 300220-3,
certifications
EN 301489 (Radio frequency certifications)
Output
Relay 12A 250Vac
HEATER operating
mode OFF forced
mode
HEATER forced
4 flash
configuration
signal (cf. configuration)
PPL IMP 2107B
during 4

Advertisement

loading

Summary of Contents for Watts EFHRFR 001

  • Page 1 USER GUIDE RADIO CONFIGURATION MODE 1 channel RF Receiver 230Vac (EFHRFR 001) Install and plug the Receiver. Then press the Receiver push button during 4 seconds, the Green LED should lit up indicating that the Receiver is now in radio configuration mode waiting for a thermostat configuration address.
  • Page 2 Per product een unieke signaalcode. Automatic , installatie verwarmt Uitgevoerd met een keuzeknop voor AUTO, MANUAL of RF INIT . Handmatig installatie uitgeschakeld Te gebruiken bij Watts RF thermostaten. Handmatig installatie ingeschakeld (verwarmen) Snel 0 of 0 of Ontvangst van een commando,...