Summary of Contents for UYIGAO MM-UA9999

  • Page 1 MM-UA9999 Smart Digital Multimeter Manual...
  • Page 2: Table Of Contents

    Safety Information ……………3 Preparation ……………3 Using ……………4 Symbols ……………4 Maintenance ……………5 Descriptions ……………5 Components ……………6 Switch And Button Instructions ……………7 LCD Display ……………8 Specifications ……………9 Summary ……………10 Technical Specifications ……………10-13 Operation Instructions ……………14 Data Hold ……………14 Function selection ……………14 Torch ……………14 Automatic Power Off ……………15...
  • Page 3: Preparation

    The instrument performance is stable, the quality of reliability is Smart Key 3 5/6 digital multimeter, using LCD display, clear reading, intuitive display, easy to operate, can be used to measure the DC voltage, AC voltage sine wave RMS, DC current, AC current sine wave True RMS, resistance, capacitance, frequency, duty cycle, diode, Data hold, Auto power off.
  • Page 4: Symbols

    instrument is damaged. 1.1.4 The pen must be in good condition. Before use, check whether the insulation of the test leads is damaged and the wires of the wires are exposed. 1.1.5 Use the table provided with the table to ensure safety, if necessary, must use the same or the same level of the pen to replace.
  • Page 5: Maintenance

    Double Insulation Protection (Class II) CAT III In accordance with IEC-61010-1 standard over-voltage (installation) level III, pollution level 2 refers to the level of pulse withstand voltage protection provided. Meet the European Community (EU) standards Grounded 1.4 Maintenance 1.4.1 Do not attempt to open the bottom case to adjust or repair the instrument. This operation can only be performed by a technician who is fully aware of the instrument and the risk of electric shock.
  • Page 6 - The instrument has an automatic range function. - The meter has a reading hold function. - The instrument has an automatic shutdown function. 2.1 Part Name (1) Torch (2) LCD display (3) NCV and Torch indicator (4) Frequency/Duty cycle Voltage and Temperature (5) 10A current input Jack (6) Resistance, capacity, voltage, frequency, Temperature, on-off test, Diode test button...
  • Page 7 2.2 Switch and button and input jacks Button: Data hold when short time press, back light on/off when long time press。 Back light will be off about 15 minutes when no signal input Button: Frequency and duty cycle switch Button: NCV when short time press, Torch functions when long time press. Button: Power on/off when long time press.
  • Page 8: Lcd Display

    2.3 LCD Display AC、DC AC , DC 、 Diode test, On-off test AUTO Auto mode Non-contact AC voltage test Transistor test status ℃ ℉ Temperature measurement status Battery week Data hold Auto power off duty ratio mV, V Millivolt, volt (voltage) Ampere (current) nF,μF,mF NaFala, micro-Farah, millifara...
  • Page 9 3. Specification The meter shall be designated for one year and recalibrated at 18 ° C to 28 ° C and a relative humidity of less than 75%. 3.1 Summary Automatic range and Manual range Full ranges overload protection. The maximum voltage allowed between the measuring end and the ground: 600V DC or AC 600V RMS Fuse protection: FF10A/250V on A Working height: max 2000m...
  • Page 10 the traditional average response method error is small. 3.2.1.2 True RMS The instrument can accurately measure the sine wave signal, but if it is on the AC function, the instrument may display 1 to 50 if the measured signal is not input (shorted at the AC voltage range and the input terminal) Word between a reading.
  • Page 11 - Input resistance:10MW - Maximum input voltage:600V AC (RMS)or 600V DC - Frequency range: 40 ~ 1000Hz True RMS Note: In the small voltage range, the test leads not connected measured circuit, the meter may be beating the readings, This is normal because of the high sensitivity of the meter,which does not affect the actual measurement results..
  • Page 12 - Minimum input current: 30mA DC or AC(rms) - Maximum input current: 10A DC or AC(rms) When the measured current is greater than 5A, the continuous measurement time is not longer than 15 seconds, after the measurement to stop the current measurement for more than 1 minute.
  • Page 13 3.2.8 Diode Test Measuring Range Resolution Function 0.001V Display approximate diode forward voltage value - Forward DC current is about 1mA - Reverse DC voltage about 3.0V - Overload protection: 250V DC or AC (RMS) 3.2.9 Capacitance Range Resolution Accuracy 9.999nF 0.001nF 99.99nF...
  • Page 14: Function Selection

    - Overload protection:250V DC or AC(RMS) - Input voltage range:1.0V~10V ac(As the measured frequency increases, the input voltage should also increase) 3.2.11 Duty Ratio Measuring Resolution Accuracy Range 0.1 – 99.9% 0.1% ±(0.1% readings + 2 digits) - Frequency response:10 ~ 10MHz -Input voltage range: 200mV ~ 10V AC (with the measured frequency increases, the input voltage should also increase) - Maximum input voltage: 250V DC and AC (RMS)
  • Page 15: Torch

    4.3 Torch and Backlight 1) If need use Torch, Press“ ” button 2 second then open the Torch., Around 15 seconds can closed automaticly.If you need re-open the Torch, please press the button 2 second 2)The Torch flashlight is LED, and its working current is large. Although the meter is equipped with timing circuit (timing time is about 15 seconds), frequent use of the Torch will shorten the battery life, so it is necessary to use the Torch as little as possible.
  • Page 16: Ac & Dc Current Measurement

    2) " "sign indicates that the input voltage or current should not exceed the indicated value, which is to protect the internal wiring from damage. 3) Place the changeover switch in the desired measurement function and range. 4) When wiring, connect the common test leads and connect the live test leads. Remove the live test line when removing the wiring.
  • Page 17 Test current: 1)Press button power on the meter 2) Connect Red /black test leads to COM and 10A input jack 3) Disconnect the circuit to be tested. Connect the black test pen to one end of the disconnected circuit (the lower voltage) and connect the red test lead to the other end of the circuit that is broken (its voltage is high).
  • Page 18 In the circuit, the normal diode should produce a forward voltage drop of 0.5V to 0.8V; however, the reverse bias reading will depend on the change in resistance of the other 4.11 Buzzer On/Off Test Warning Risk of electric shock. To avoid damage to the meter or the device under test, all power to the circuit under test should be cut off and all high voltage capacitors should be fully discharged before the beep on-off test.
  • Page 19: Temperature

    damaging the instrument 4.13 Temperature Measurement Warning Do not enter a temperature higher than 60V AC voltage 30V AC voltage to avoid damage or instrument damage 1) Connect the negative terminal (black) and the positive terminal (red) of the K type thermocouple to the COM input jack and input jack separately.
  • Page 20 In order to avoid the wrong reading caused by electric shock or personal injury, instrument display appears “ ” Symbol, you should replace the battery immediately. To avoid electrical shock or personal injury, turn off the battery cover before replacing the battery, and check that the test leads have been disconnected from the measuring circuit.
  • Page 21 please contact the manufacturer * * The Company does not assume any accidents and hazards caused by incorrect operation of the user * * The functions described in this manual do not serve as a reason for the use of the product for special purposes * Product warranty instructions Product certification is your instrument in the use of failure, seeking repair services must have,...