Diametral AC250K1D Manual

Ac power supply

Advertisement

Quick Links

MODEL:
Dear Customer,
Thank you for your decision to buy the Alternating Current Power Supply of model line
AC250Kxxx manufactured by our company. Thanks to this purchase you obtained high-quality
and efficient helper for your work. Please read this manual to allow him to serve you many
years without troubles.
The Alternating Current (AC) Power Supply controlled by a processor can be used especially
on the places, where is necessary to supply the power to different equipment by AC 0V÷255V.
Its characteristics can be evaluated especially by development technicians, repairmen of
consumer electronics, manufacturers and last but not least also by the vocational schools.
Output voltage is obtaining by transformation of the mains voltage 230V/50Hz by a separate
transformer. Thanks to it has the output voltage the clear sine continuance of 50Hz. The
regulation of the output voltage is in the voltage range of 0 ÷ 255V, with regulation step 1V and
maximal current output 1A or 2A - according to the model type.
Controlling of the power supply is maintained by the keyboard placed on the device head panel
or with the assistance of the personal computer and its D-View software, via the interface
RS232. Using of this D-View software allows you to define the processes depending on the
time and voltage without any stint. The power supply output is controlled by its own press
button with a pilot light for easy control. Pressing of any key is signalized by a sound signal.
The power supply is equipped with 3-figure display for set voltage values. The real voltage is
displayed by 3-figure digital measuring equipment.
The power supply output is made by socket for 230V/16A.
The transformer is sufficiently dimensioned for permanent supply of the maximal output to the
loading.
The model AC250Kx-S is additionally equipped with the stabilization of the output voltage,
limitation of the maximal voltage under a password, saving of the source statuses before
switching-off and their recovering after switching-on again.
Content:
I.
II.
Technical parameters
III.
IV.
V.
V.I.
V.II.
V.III.
AC POWER SUPPLY
AC250K1D
AC250K1D-S
AC250K2D
AC250K2D-S
page 2
page 2
page 3
page 4
page 5
page 5
page 5
page 6
- 1 -

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AC250K1D and is the answer not in the manual?

Questions and answers

Summary of Contents for Diametral AC250K1D

  • Page 1: Table Of Contents

    3 Safety instructions page 4 Work with the laboratory power supply page 5 V.I. Voltage output setup page 5 V.II. Accurate setting of the voltage output page 5 V.III. Stabilization (only model AC250K1D-S and AC250K2D-S) page 6 - 1 -...
  • Page 2: The Set Contents

    1 x Serial Communication Cable for the Interface RS232 1 x Instruction Manual 1 x D-View AC1 Software II. Technical specifications Model AC250K1D AC250K1D-S AC250K2D AC250K2D-S Mains Voltage: --- 230V/50Hz --- --- 0 ÷ 255V --- Output Voltage: Output Frequency:...
  • Page 3: Description Of The Operating Elements

    WARNING: The voltage output is galvanically separated from the mains – outgoing connector PE is not connected. This device is determined for the internal use only! III. Description of the operating elements - 3 -...
  • Page 4: Safety Instructions

    - display for setup of the voltage value - output indicator – the light signalize the presence of a voltage on the output - indicator for confirmed/unconfirmed set voltage value by pressing ENTER - controlling keyboard - main switch for the mains - output safety fuse –...
  • Page 5: Work With The Laboratory Power Supply

    During this period is the output of the device blocked (7). Model AC250K1D (AC250K2D): Approximately after two seconds are the displays switched to the operational mode and show 0. At the same time is activated the control keyboard (4) and a short acoustic signal sounds.
  • Page 6: Stabilization (Only Model Ac250K1D-S And Ac250K2D-S)

    V.III. Stabilization (only the model AC250K1D-S and AC250K2D-S) V.III.I. Switching-on of the stabilization, saving of the last voltage value, output characteristics mode V.III.I.I. Data definition Stabilization YES: yes, stabilization is switched ON no, stabilization is switched OFF Tolerance of the stabilisation in the range of 1 ÷ 9V (hysteresis)
  • Page 7: Disconnection Of The Communication Interface Rs232

    Keep the key C (15) for three seconds. The sign StA (stabilization) will appear on the display SET (3) and on the display REAL (8) its momentary status (On/Off). By pressing the key DOWN (11) you will disable the stabilization, by pressing the key UP (10) the stabilization will be allowed.
  • Page 8: Controlling Via Parent Computer

    you will return back to the normal operation mode of the power supply. V.V. Controlling via parent computer Connect the AC Power Supply with using the supplied serial cable to the serial port of the computer (COM1 or COM2). Do not use any other serial cable than the one supplied together with the source - otherwise you can damage the power supply or computer! Install the controlling software D-View AC1.
  • Page 9: Maintenance

    The displays show the pre-set values, but on Push the button for appropriate output. the output is not any voltage. The displays show the set up values, but on Sublimated safety fuse of the output. Change the output is not any voltage. it according to the Chapter VI.
  • Page 10: Warranty And After-Warranty Services

    In the case of a defect please send the product to your dealer. Address of manufacturer: Diametral spol. s r.o, Náchodská 760, 193 00 Praha - Horní Počernice, Czech republic phone-fax: +420 2 8192 5939, 2 8192 5940, 2 8186 3157.
  • Page 11 Declaration of Conformity Manufacturer Commercial Name: Diametral spol. s.r.o. Location: Fr. Kadlece 12/849 180 00 Praha 8 Company Identification Number: 45796807 Product Name: Alternating Current (AC) Power Supply Type: AC250K1D, AC250K1D-S AC250K2D, AC250K2D-S List of applied prescripts: Safety: 61010-1:1995 60065: 2000...
  • Page 12 Date of repair Date of repair Date of repair Printing, copying and translating (even a part) is not allowed without previous written approval of the company Diametral Ltd. All rights consequential to the Copyright have entirely the company Diametral Ltd. © 2000 I.

This manual is also suitable for:

Ac250k1d-sAc250k2dAc250k2d-s

Table of Contents