BEFORE YOU INSTALL

This installation should only be performed by a qualified tradesperson. Where possible, use a trained Sirius recommended
installer (see Siriusbrand.com). Sirius will not be held responsible for issues that occur due to installation of product by an
unqualified tradesperson.
All motors must be accessible for servicing purposes and if installed above 2 metres from ground height additional
cost will be incurred due to OH&S standards for service agents. Prior to install please check minimum & maximum
installation details on the Sirius website, FAQ under support tab. Service is offered during normal business hours only,
also appliances to have a clear access in a serviceable area.
The ducting of the rangehood must not be connected to ducting which is used for exhausting other fumes from
appliances, such as central heating, boilers etc.
For the external exhausting of the fumes, comply with the Australian building standards.
Ventilate the room suitably according to the Australian building standards when the appliance is working together with
gas or oil appliances.
The SEM motor is powered by the rangehood. Standard 10AMP GPO at the point of rangehood required.
Before connecting the rangehood to the mains supply, make sure that the voltage indicated in the rating plate
corresponds to the mains voltage in the home.
Before carrying out any sort of maintenance or cleaning operation, make sure that the appliance is disconnected from
the electrical mains.
INSTALLATION OF YOUR SIRIUS RANGEHOOD
Rangehood and SEM motor cannot be installed back-to-back. There must be a minimum of 2 metres
between rangehood and motor for noise reduction reasons.
Only use ducting that falls within the necessary minimum and maximum length requirements as specified in the
installation guide.
Try and minimise bends to the ducting for optimum performance.
Use only suitable ducting as specified by Sirius. Under no circumstances is flexible ducting to be used as it creates
unwanted noise, vibration and can place the motor under unnecessary stress resulting in premature failure of the SEM
motor.
Under no circumstances is the duct diameter is the duct diameter to be reduced. A constant minimum diameter of
150mm for the SEM 11 / 21 / 51 must be maintained at all times.
For SEM 71 / 81 motors a constant diameter of 200mm must be maintained at all times.
Read the mounting and operating instructions of the rangehood carefully.
The manufacturer cannot be held responsible for a decrease of the airflow or for an increase of noise level caused by
non-compliance with the instructions above.

MOTOR WIRING CONNECTION

1. Remove the four screws holding the front of the housing in place to
expose the connections.
2. Following the wiring chart on the front of the housing, connect each wire
to the matching colour, making sure that this is done correctly before running
power to the unit.
3. Replace the cover and fix the four screws back into place.