PMC 200426 Service Manual

2.5 gallon flush tank

Advertisement

Quick Links

Before using the Flush Tank, carefully read all the technical and safety
documentation included in this manual. Pay special attention to the
information in order to know and understand the operation and the
conditions of use of the Flush Tank. All of the information is aimed at
improving user safety and avoiding possible breakdowns from the
incorrect use of the Flush Tank.
200426
200427
2.5 Gallon Flush Tank
For Professional Use Only
Not approved for use in explosive
atmosphere locations
Service Manual
Ref. # MN-04025
Revision 1.2
October 20, 2020
Polyurethane Machinery Corp.
Corporate: 1 Komo Dr, Lakewood, NJ 08701
Manufacturing: 2 Komo Dr, Lakewood, NJ 08701
Phone: 732-415-4400
Fax: 732-364-4025
URL:
http://www.polymac-usa.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 200426 and is the answer not in the manual?

Questions and answers

Summary of Contents for PMC 200426

  • Page 1 200426 200427 2.5 Gallon Flush Tank For Professional Use Only Not approved for use in explosive atmosphere locations Service Manual Ref. # MN-04025 Revision 1.2 October 20, 2020 Polyurethane Machinery Corp. Corporate: 1 Komo Dr, Lakewood, NJ 08701 Manufacturing: 2 Komo Dr, Lakewood, NJ 08701...
  • Page 2: Table Of Contents

    TABLE OF CONTENTS WARRANTY ............................1 SAFETY AND HANDLING ........................3 CHARACTERISTICS .......................... 5 TECHNICAL SPECIFICATIONS ......................5 DESCRIPTION ............................ 6 START UP ............................7 FLUSHING PROCEDURE........................8 PART IDENTIFICATION ........................9 Flush Tank Assemblies ........................9 Flush Tank Body Assembly ......................10 Coupling Block Assemblies ......................
  • Page 3: Warranty

    Defective in material or workmanship, it is Customer’s responsibility to contact PMC and return the Product to PMC as directed by PMC, freight prepaid. If PMC determines that the Product is Defective and that such Defect is covered by this Warranty, PMC will credit Customer for the reasonable freight charges incurred by Customer in returning the Defective Product to PMC, and PMC (or its authorized agent) will, at PMC’s option, repair or replace the Product, subject to the...
  • Page 4 No Rights Implied: Nothing in the sale, lease or rental of any Product by PMC shall be construed to grant any right, interest or license in or under any patent, trademark, copyright, trade secret or other proprietary right or material owned by anyone;...
  • Page 5: Safety And Handling

    Keep this Operations Manual for future consultation of useful information at all times. If you lose this manual, ask for a new copy from your PMC Distributor or go online and visit our web site at www.polymac-usa.com.
  • Page 6 Always use liquids and solvents that are compatible with the unit. If in doubt, consult your PMC Distributor. When working with the Flush Tank, it is recommended that the operator wear suitable clothing and elements of personal protection, including, without limitation, gloves, protective goggles, safety footwear, and face masks.
  • Page 7: Characteristics

    CHARACTERISTICS • Quick and easy installation • No electricity required • Flow control • Portable and versatile system TECHNICAL SPECIFICATIONS Maximum Working Pressure _______________________________________ 100 PSI (7.0 bar) Pressure Relief Valve Rating _______________________________________ 100 PSI (7.0 bar) Air Hose Connection _________________________________________ 1/4” Quick Disconnect Solvent Hose Length ________________________________________________ 36 in (0.91 m)
  • Page 8: Description

    DESCRIPTION 1. Flush Tank Body 2. Flush Tank Lid 3. Pressure Relief Valve 4. Pressure Gauge 5. Solvent Hose 6. Coupling Block 7. Quick Disconnect 8. Inlet Valve 9. Primary Outlet Valve 10. Secondary Outlet Valve...
  • Page 9: Start Up

    START UP 1. Relieve fluid pressure in the gun (See Gun Manual for proper procedure) 2. If necessary, relieve air pressure in the tank by pulling Pressure Relief Valve. 3. Ensure ALL Valves are in the closed position. 4. Open the lid and fill tank 2/3 full with compatible solvent.
  • Page 10: Flushing Procedure

    FLUSHING PROCEDURE 1. Ensure ALL Valves are closed. 2. Attach Coupling Block to the spray gun. 3. Open the Primary Outlet Valve, and then open the Secondary Outlet Valve. 4. Direct the gun into a grounded metal pail, ensuring that the flush coupling block maintaining direct contact...
  • Page 11: Part Identification

    PART IDENTIFICATION Flush Tank Assemblies 200426, 200427 PARTS LIST INCLUDED IN ITEM QTY PART NUMBER DESCRIPTION PART NUMBER 200413 FLUSH TANK BODY ASSEMBLY HI-05106 COUPLING BLOCK ASSEMBLY, FLUSH KIT, AP 200426 200218 COUPLING BLOCK ASSEMBLY, FLUSH KIT, F-AP 200427...
  • Page 12: Flush Tank Body Assembly

    PART IDENTIFICATION Flush Tank Body Assembly 200413 PARTS LIST ITEM PART NUMBER DESCRIPTION 200400 2.5 GAL FLUSH TANK 200401 FLUSH TANK FITTING GP-00100-1 1/4 PIPE NIPPLE GU-04022 QUICK DISCONNECT; MALE GU-04021 QUICK DISCONNECT; FEMALE GP-00100-3 MALE RUN TEE HI-05105 NPT REDUCER NE-06007 AIR PRESSURE GAUGE PU-04000-82...
  • Page 13: Coupling Block Assemblies

    PART IDENTIFICATION Coupling Block Assemblies HI-05106, 200218 PARTS LIST INCLUDED IN ITEM PART NUMBER DESCRIPTION PART NUMBER RM-05106 COUPLING BLOCK, FLUSH KIT, AP HI-05106 200214 COUPLING BLOCK, FLUSH KIT, F-AP 200218 TN-04187 SHCS 10-32 X 3/16 PORT PLUG TN-04193 COUPLING BLOCK MOUNTING SCREW TN-04197 COUPLING BLOCK STABILIZER MOUNTING SCREW Replacement Tank O-Ring...

This manual is also suitable for: