Download Print this page

Furuno BC-6158 Owner's Manual

Furuno battery charger owner's manual

Advertisement

Quick Links

4.4 Battery charger (BC-6158)
4.4.1 Connection of battery charger and battery monitor circuit
Battery charger BC-6158 is controlled from the battery control panel of the console
panel.
A
V
RC-1800T only
TB2
60A
Battery
SB-180
TB1
AC100/220V
Fig. 4.4.1 Connection of battery charger and battery monitor circuit
The battery monitor circuit (05P0607) monitors battery voltage.
If battery voltage drops to 22 V, [LOW] indicator comes on and the buzzer sounds.
With "BATT CHARGER switch" set to "AUTO", the charger starts charging the battery
when the battery voltage drops to 24.5 to 25.0 V, and stops charging when the battery is
charged by 28.0 to 28.5 V automatically. If the switch is set to "MANUAL", the battery
is charged in continuity. The signal to control charging is "3. CHARGE-L" signal which
turns ON/OFF relay K1 on the AC power supply line of BC-6158.
AC FAIL signal from PR-850A (AR), a contact signal of the relay is output when AC
supply is turned "OFF" and switched to the battery.
This signal is supplied to "2. EMG-L" of the battery monitor board to indicate "IN
USE". This signal is also supplied to FS-5000/2550/1562-25 and automatically reduces
the transmission power to 60 to 70 W.
Note) The "AUTO" position is provided to prevent over discharge of the battery.
This "AUTO" position is not intended to use both the battery and AC/DC supplies
at the same time for so called "floating operation".
BC-6158
TB3
3. (+)BATT OUT
4. (-)BATT OUT
6. CHARGE
EMG
Lamp
K1
T1
AC iN
REC
Illuumination
Lamp
1. BATT IN+
2. BATT IN-
5. 24V
7. 0V
24V OUT
1. AC(U)
PR-850A
2. AC(V)
PR-850AR
1. (+)BATT OUT
2. (-)BATT OUT
4-12
05P0607
BATT CH. SW
4. BATT+
5. BATT-
AUTO
OFF
3. CHRG-L
CHARGE
CHARGE
EMG LIGHT
6. LAMP 2(NC)
ON
7. LAMP 1
OFF
IN USE
1. 24V
2. EMG L
24V Back-up
24V Back-up
24V
AC FAIL
Back-up
24V
Back-up
PR-300
(RC-1800T)
AC100/220V
AC100/220V
4.4 Battery charger(BC-6158)
MF/HF SSB
AC FAIL
Primary system
Duplicate system

Advertisement

loading

Summary of Contents for Furuno BC-6158

  • Page 1 4.4 Battery charger (BC-6158) 4.4.1 Connection of battery charger and battery monitor circuit Battery charger BC-6158 is controlled from the battery control panel of the console panel. BC-6158 AC iN RC-1800T only 1. BATT IN+ Battery 2. BATT IN- SB-180 AC100/220V 1.
  • Page 2 4.4.3 Battery charger (BC-6158) Battery charger BC-6158 can charge clad type or pasteboard vent type batteries of up to 300 AH. It is a constant voltage/current charger which supplies a constant voltage of 28 V and a constant charging current of 20 A (30 A).
  • Page 3 3.4 BC-6158: Battery charger unit Breaker: :30A (CP1) (Over current ADJ. VR.: Adjust to 20A) 05P0659 R1/2 Rectifier Ω (U2) (0.5 /50W) Rectifier (U1) Upper terminal:TB2 Lower terminal:TB1 Fig. 3.4.1 BC-6158 (Over voltage ADJ. VR.: Adjust to 28V) Fig. 3.4.2 BC-6158 left side 3-12 3.4 BC-6158...