Hide thumbs Also See for OR4 basic:

Advertisement

Quick Links

OR4 basic | OR4 pro
Smoke detector according to DIN EN 54-27 with VdS recognition and DIBt approval Z-78.6-250
USER MANUAL
WILDEBOER BAUTEILE GMBH
Issue: 2021-12
5.14

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the OR4 basic and is the answer not in the manual?

Questions and answers

Summary of Contents for Wildeboer OR4 basic

  • Page 1 OR4 basic | OR4 pro Smoke detector according to DIN EN 54-27 with VdS recognition and DIBt approval Z-78.6-250 USER MANUAL 5.14 WILDEBOER BAUTEILE GMBH Issue: 2021-12...
  • Page 2: Table Of Contents

    ƒ For use in particularly cramped installation scenarios You will find further information on out product website. Use the QR code to open the link. Page 2/16 Issue 2021-12 User manual 5.14 - OR4 basic / OR4 pro (C6584.005.038-09) Subject to error/change...
  • Page 3: Application

    Galvanically isolated with BACnet MS/TP and RS485 Modbus RTU ƒ An overview of equipment variants OR4 basic and OR4 pro can be found on Page 5. ƒ Refer to the installation and operating instructions for detailed information on mechanical and electrical installation. Page 3/16 User manual 5.14 - OR4 basic / OR4 pro (C6584.005.038-09)
  • Page 4: Product Overview

    Optional: Saddle pipe For installation of the smoke detector in circular ventilation ducts. Page 4/16 Issue 2021-12 User manual 5.14 - OR4 basic / OR4 pro (C6584.005.038-09) Subject to error/change...
  • Page 5: Or4 Basic/Or4 Pro

    24 V AC/DC (SELV), 250 V AC, min. 11 mA, max. 8 A Max. bounce time, closing/ 4 ms / 10 ms opening For further technical data see  Page 13. Page 5/16 User manual 5.14 - OR4 basic / OR4 pro (C6584.005.038-09) Issue 2021-12 Subject to error/change...
  • Page 6: Function

    The gap upstream and downstream of disruption points (of all kinds) must be at least 1.5 x d (hydraulic diameter). min.1.5 xd min. 1.5 xd Disruption point Page 6/16 Issue 2021-12 User manual 5.14 - OR4 basic / OR4 pro (C6584.005.038-09) Subject to error/change...
  • Page 7: Installation In Circular Ventilation Ducts

    Page 7/16 User manual 5.14 - OR4 basic / OR4 pro (C6584.005.038-09) Issue 2021-12 Subject to error/change...
  • Page 8: Installation In Rectangular Ventilation Ducts

    In the process, align the when the smoke detector has installation socket to the not yet been installed during direction of air. the construction stage. Page 8/16 Issue 2021-12 User manual 5.14 - OR4 basic / OR4 pro (C6584.005.038-09) Subject to error/change...
  • Page 9: Dimensions

    ƒ Alarms and faults saved in case of power failure ƒ DIBt approval Z-78.6-250 ƒ VdS approval G 221008 To product website Equipment variant Optional: basic OR4 basic variant OR4 pro variant Page 9/16 User manual 5.14 - OR4 basic / OR4 pro (C6584.005.038-09) Issue 2021-12 Subject to error/change...
  • Page 10: Options

    ZUB 0472 1 x flow insert with flow sensor (OR4 pro) ZUB 0474 1 x flow insert without flow sensor (OR4 basic) ZUB 0473 Page 10/16 Issue 2021-12 User manual 5.14 - OR4 basic / OR4 pro (C6584.005.038-09) Subject to error/change...
  • Page 11: Specification Text

    100 mm or more..pcs. Supply voltage: 230 V AC / 24 V AC/DC Manufacturer: WILDEBOER Type/series: OR4 pro VdS approval: G221008 Page 11/16 User manual 5.14 - OR4 basic / OR4 pro (C6584.005.038-09) Issue 2021-12 Subject to error/change...
  • Page 12: Annex

    Activate flow sensor (ventilation system in operation) GLT interface (RS485) Connection Signal OR4 basic OR4 pro OR4 pro 1, 4 2, 5 3, 6 Shield Page 12/16 Issue 2021-12 User manual 5.14 - OR4 basic / OR4 pro (C6584.005.038-09) Subject to error/change...
  • Page 13: Technical Data

    2.5 mm blade width The technical data applies at input voltage nominal values and +24 °C Current rating 10 A per contact ambient temperature. Page 13/16 User manual 5.14 - OR4 basic / OR4 pro (C6584.005.038-09) Issue 2021-12 Subject to error/change...
  • Page 14 Annex Smoke detector OR4 basic/OR4 pro Notes Page 14/16 Issue 2021-12 User manual 5.14 - OR4 basic / OR4 pro (C6584.005.038-09) Subject to error/change...
  • Page 15 Annex Smoke detector OR4 basic/OR4 pro Notes Page 15/16 User manual 5.14 - OR4 basic / OR4 pro (C6584.005.038-09) Issue 2021-12 Subject to error/change...
  • Page 16 E-mail: info@utrecht.wildeboer.eu FRANKFURT Internet: www.wildeboer.de/nl Leipzig office Telephone: +49 34444 - 310 - 0 E-mail: info@leipzig.wildeboer.de STUTTGART Internet: www.wildeboer.de MUNICH Ulm office Telephone: +49 7392 - 9692 - 0 E-mail: info@ulm.wildeboer.de Internet: www.wildeboer.de MAKE USE OF OUR STRENGTHS! WILDEBOER BAUTEILE GMBH...

This manual is also suitable for:

Or4 proRl4 basicRl4 pro

Table of Contents