Sign In
Upload
Download
Table of Contents
Contents
Add to my manuals
Delete from my manuals
Share
URL of this page:
HTML Link:
Bookmark this page
Add
Manual will be automatically added to "My Manuals"
Print this page
×
Bookmark added
×
Added to my manuals
Manuals
Brands
Flexitron Manuals
Control Unit
Webdyn WebdynModbus
User manual
Flexitron Webdyn WebdynModbus User Manual
Hide thumbs
1
Table Of Contents
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
page
of
73
Go
/
73
Contents
Table of Contents
Bookmarks
Table of Contents
Table of Contents
User Manual
Glossary
About this Document
Scope
Target Audience
Product Versions
Safety Advice
Principles of Operation
Overview Diagram of a Comprehensive Monitoring Solution
Unit Characteristics
Technical Characteristics
List of Available Interfaces
Optional Accessories
DIN Rail Power Supply
GSM/GPRS Right-Angled Stub Antenna
GSM/GPRS Externally Mounted Antenna (Optional)
Prerequisites
Access to the FTP Server
Access to the NTP Server
Connection Via GPRS or Ethernet
Ethernet Connection
GPRS Connection
Managing the PIN Code for the SIM Card
Gateway Configuration
Role of the Configuration Files
Configuration Files
Definition Files
Initialization
Configuration Via the Built-In Web Server
Configuration Via SMS
Advertisement
Quick Links
Download this manual
WebdynModbus
User Manual
www.webdyn.com
Table of
Contents
Previous
Page
Next
Page
1
2
3
4
5
Advertisement
Table of Contents
Related Manuals for Flexitron Webdyn WebdynModbus
Control Unit Flexitron Webdyn MTX-StarEnergy-M Software User Manual
(42 pages)
Summary of Contents for Flexitron Webdyn WebdynModbus
Page 1
WebdynModbus User Manual www.webdyn.com...
Page 2: Table Of Contents
6.1.1 Configuration Files ...................... 16 6.1.2 Definition Files ......................17 6.2 Initialization ..........................17 6.2.1 Configuration via the Built-in Web Server ..............20 6.2.2 Configuration via SMS ....................26 contact@webdyn.com | webdyn.com V1.0 subject to changes | Webdyn © by Flexitron Group...
Page 3
9. Using Web Services ..........................57 9.1 Enabling and Configuring ......................57 9.2 Format of HTTP Requests ......................57 9.3 Examples of Web Services Requests ..................61 contact@webdyn.com | webdyn.com V1.0 subject to changes | Webdyn © by Flexitron Group...
Page 4
10.4 LED Indicators ........................67 10.5 Installation Button ......................... 69 10.6 Diagnostic SMS ........................69 10.7 Debug Traces ......................... 70 10.8 Factory Reset Procedure ...................... 71 Sales Contact ........................73 contact@webdyn.com | webdyn.com V1.0 subject to changes | Webdyn © by Flexitron Group...
Page 5: User Manual
TCP/IP includes standards for communication between computers and conventions for network interconnection and for routing. contact@webdyn.com | webdyn.com V1.0 subject to changes | Webdyn © by Flexitron Group...
Page 6: About This Document
(DC and AC). The WebdynModbus unit is liable to damage from electrostatic discharge (ESD). Avoid all contact with component connectors and terminals. contact@webdyn.com | webdyn.com V1.0 subject to changes | Webdyn © by Flexitron Group...
Page 7: Principles Of Operation
3.1 Overview Diagram of a Comprehensive Monitoring Solution Modbus Inverters Modbus Modbus equipment Ethernet/ 4G/3G/2G Server User WebdynModbus WebdynModbus Modbus 888888 Meters Modbus Sensors contact@webdyn.com | webdyn.com V1.0 subject to changes | Webdyn © by Flexitron Group...
Page 8: Unit Characteristics
ENVIRONMENTAL CONDITIONS Operational temperature range -5°C à +55°C Storage temperature -5°C à +45°C (1) Measurements carried out on the Unit + DIN Rail DR15-24 power supply assembly contact@webdyn.com | webdyn.com V1.0 subject to changes | Webdyn © by Flexitron Group...
Page 9: List Of Available Interfaces
This power supply unit is mounted next to the gateway on the standard 35-mm DIN RAIL metal rail. This rail mounting means that no other mounting bracket is required. contact@webdyn.com | webdyn.com V1.0 subject to changes | Webdyn © by Flexitron Group...
Page 10
VOLTAGE RANGE 85 ~ 264VAC 120 ~ 370VDC FREQUENCY 47 ~ 63Hz RANGE EFFICIENCY (Typ.) AC CURRENT (Typ.) 0.88A/115VAC; 0.48A/230VAC INRUSH CURRENT COLD START 35A/115VAC; 65A/230VAC (Typ.) contact@webdyn.com | webdyn.com V1.0 subject to changes | Webdyn © by Flexitron Group...
Page 11
Compliance to EN61000-4-2, 3, 4, 5, 6, 8, 11, ENV50204, EN55024, EN61000-6-2, EN61204-3, heavy industry level, criteria A OTHERS MTBF 1172.3K hr min. MIL-HDBK-217F (25 ) DIMENSION 25*93*56mm (W*H*D) contact@webdyn.com | webdyn.com V1.0 subject to changes | Webdyn © by Flexitron Group...
Page 12: Gsm/Gprs Right-Angled Stub Antenna
900-1800 MHz 4.3.3 GSM/GPRS Externally Mounted Antenna (optional) Characteristics: Cable: RG-58 Cable length: 5,10 or 20 meters available Frequency ranges 824-960 MHz; 1710-1990 MHz Options Mounting bracket contact@webdyn.com | webdyn.com V1.0 subject to changes | Webdyn © by Flexitron Group...
Page 13: Prerequisites
• /DATA: Directory for upload of data files. This directory contains four subdirectories: • /MODBUS: Modbus data. • /DEF: Contains the definition files for the modules and sensors to be controlled. This directory contact@webdyn.com | webdyn.com V1.0 subject to changes | Webdyn © by Flexitron Group...
Page 14: Access To The Ntp Server
The management of the SIM card’s PIN code is as follows: • If the PIN code is deactivated: GPRS communication is operational for the gateway. contact@webdyn.com | webdyn.com V1.0 subject to changes | Webdyn © by Flexitron Group...
Page 15
WebdynModBus, WebdynSun, WebdynPulse, or WebdynTIC. If you do so, the SIM card will be blocked and the user will have to unblock it by entering the PUK code manually. contact@webdyn.com | webdyn.com V1.0 subject to changes | Webdyn © by Flexitron Group...
Page 16: Gateway Configuration
Should a modification be detected, the gateway downloads the new file. The details of each parameter in the configuration files will be explained as required in the remainder of this documentation. contact@webdyn.com | webdyn.com V1.0 subject to changes | Webdyn © by Flexitron Group...
Page 17: Definition Files
LAN subnet mask 255.255.255.0 Communication via Ethernet (up to 15 characters) LAN_Gateway Address of the gateway 0.0.0.0 (router) on the LAN Communication via Ethernet (up to 15 characters) contact@webdyn.com | webdyn.com V1.0 subject to changes | Webdyn © by Flexitron Group...
Page 18
Service Provider (ISP) (up to 13 characters) FAI_Login PSTN identifier empty Provided by the ISP (up to 29 characters) FAI_Password PSTN password empty Provided by the ISP (up to 29 characters) contact@webdyn.com | webdyn.com V1.0 subject to changes | Webdyn © by Flexitron Group...
Page 19
(up to 29 characters) FTP_DirAlarm FTP directory name for /ALARM alarm files (up to 29 characters) FTP_DirCmd FTP directory name for /CMD command files (up to 29 characters) contact@webdyn.com | webdyn.com V1.0 subject to changes | Webdyn © by Flexitron Group...
Page 20: Configuration Via The Built-In Web Server
In addition, both the computer used and the gateway must belong to the same local network. If the WebdynModbus gateway has a static IP address (the default situation), the contact@webdyn.com | webdyn.com V1.0 subject to changes | Webdyn © by Flexitron Group...
Page 21
• The following window is displayed: • Web interface access credentials:: On delivery, the settings of the WebdynPulse gateway are as follows: User Name: userhigh Password: high contact@webdyn.com | webdyn.com V1.0 subject to changes | Webdyn © by Flexitron Group...
Page 22
The Configuration page allows you to: • Choose the Web interface language. • Configure the gateway identifier. • Complete the GPRS/Ethernet connection parameters, and the http/ftp servers. contact@webdyn.com | webdyn.com V1.0 subject to changes | Webdyn © by Flexitron Group...
Page 23
• Manually, in the ID field (by default “ID=WDXXXXXX” where XXXXXX is the last six digits of the MAC address). • Automatically, by ticking the Automatic mode checkbox and leaving the ID field empty (“ID= “). contact@webdyn.com | webdyn.com V1.0 subject to changes | Webdyn © by Flexitron Group...
Page 24
• Password: enter the password for the APN supplied by your mobile operator. Consult your mobile operator to obtain the information pertaining to your SIM card (APN, user ID and password). contact@webdyn.com | webdyn.com V1.0 subject to changes | Webdyn © by Flexitron Group...
Page 25
Once all the parameters have been specified, click on OK. A message will appear at the top of the page to indicate that the gateway must be restarted to take the new parameters into account. contact@webdyn.com | webdyn.com V1.0 subject to changes | Webdyn © by Flexitron Group...
Page 26: Configuration Via Sms
SMS to configure the remote FTP server: Send the following SMS to the WebdynPulse: “ftp=server_name:user_name:password:port;” Where: server_name: Symbolic name or IP address of the remote FTP server. contact@webdyn.com | webdyn.com V1.0 subject to changes | Webdyn © by Flexitron Group...
Page 27
DEFAULT VALUE NTP_Server1 IP address for the main NTP server (up to 29 pool.ntp.org characters) NTP_Server2 IP address for the backup NTP server (up to 29 characters) contact@webdyn.com | webdyn.com V1.0 subject to changes | Webdyn © by Flexitron Group...
Page 28
• Upload of input/output data files • Upload of electric meter files • Configuration file management • Definition file management • Log management • Firmware update management contact@webdyn.com | webdyn.com V1.0 subject to changes | Webdyn © by Flexitron Group...
Page 29
If =0: connection every day at the time specified by the variables “Connection_Hour” and “Connection_Minute” Connection_Hour Hour for connection to the remote FTP server Connection_Minute Minute for connection to the remote FTP server contact@webdyn.com | webdyn.com V1.0 subject to changes | Webdyn © by Flexitron Group...
Page 30
Hour for connecting to remote FTP server Connection_Minute3 Minute for connecting to remote FTP server Connection_Hour4 Hour for connecting to remote FTP server Connection_Minute4 Minute for connecting to remote FTP server contact@webdyn.com | webdyn.com V1.0 subject to changes | Webdyn © by Flexitron Group...
Page 31
Example: Configuration: Connection_OnDataAcquisition=1 Connection_Period=0 Connection_Hour=23 Connection_Minute=0 And the data capture period is defined to be 15 minutes: DAQ_Period=15 contact@webdyn.com | webdyn.com V1.0 subject to changes | Webdyn © by Flexitron Group...
Page 32
In this second case, the product will collect all the alarms and they will be uploaded to the FTP server after the next acquisition point. contact@webdyn.com | webdyn.com V1.0 subject to changes | Webdyn © by Flexitron Group...
Page 33
VARIABLE DEFINITION COMMENTS DEFAULT VALUE DAQ_Period Collection interval in minutes common Possible value to all data sources (Inverters, TIC, I/O, from 0 to 59 Modbus) minutes contact@webdyn.com | webdyn.com V1.0 subject to changes | Webdyn © by Flexitron Group...
Page 34
A data acquisition time slot can be defined using the variables listed below, in the file prefixID_var.ini. VARIABLE DEFINITION DEFAULT VALUE DAQ_ Acquisition start hour TimeZoneStartHour DAQ_ Acquisition start minute TimeZoneStartMinute DAQ_ Acquisition end hour TimeZoneStopHour DAQ_ Acquisition end minute TimeZoneStopMinute contact@webdyn.com | webdyn.com V1.0 subject to changes | Webdyn © by Flexitron Group...
Page 35
Communication with Modbus devices can be done via RS485 (using 2 or 4 wires), RS232 or Ethernet. This choice must be informed to the gateway via the configuration file prefixID_daq.ini. contact@webdyn.com | webdyn.com V1.0 subject to changes | Webdyn © by Flexitron Group...
Page 36
The discovery of Modbus devices is impossible. Thus, every device present on the bus must be declared in the prefixID_daq.ini file. This configuration is done via the FTP server. The file prefixID_daq.ini must contain the parameters listed below: contact@webdyn.com | webdyn.com V1.0 subject to changes | Webdyn © by Flexitron Group...
Page 37
RS485 with 2 or 4 wires 0: RS232 1: RS485, 2 wires 2: RS485, 4 wires MODBUS_ Speed of the serial link: 9600 BaudRate 1200 2400 9600 19200 38400 57600 115200 contact@webdyn.com | webdyn.com V1.0 subject to changes | Webdyn © by Flexitron Group...
Page 38
Type[n] if not 0 Used only in specific cases such as Mersen devices. MODBUS_ Medium used: n=0 to 246 Interface[n] 0: Serial interface (RS485/ RS232) 1: Ethernet contact@webdyn.com | webdyn.com V1.0 subject to changes | Webdyn © by Flexitron Group...
Page 39
Every Modbus slave declared in the configuration file prefixID_daq.ini must have a definition file. The purpose of this file is to describe the whole set of variables available for a Modbus device. contact@webdyn.com | webdyn.com V1.0 subject to changes | Webdyn © by Flexitron Group...
Page 40
Write function code and function sub-code: 0 to 65535 Standard codes handled: 5 => “write single coils” 6 => “write single register” 15 => “write multiple coils” 16 => “write multiple registers” contact@webdyn.com | webdyn.com V1.0 subject to changes | Webdyn © by Flexitron Group...
Page 41
Description, index for the variable, from 1 to N indexRequest Designation of the Modbus request, defined in the table Modbus_ RequestsTables. name Designation of the Modbus variable. contact@webdyn.com | webdyn.com V1.0 subject to changes | Webdyn © by Flexitron Group...
Page 42
0: variable not collected. 1: variable handled as a parameter. 2: minimum, maximum and calculated average collected. 4: instantaneous value 8: alarm triggered on change of status contact@webdyn.com | webdyn.com V1.0 subject to changes | Webdyn © by Flexitron Group...
Page 43
Not supplied Not supplied Not supplied option2 Not supplied Not supplied Not supplied Modbus_RequestsTables={ 1;counter;3;0;0;4;1;2 2;output;1;5;4;4;1;1 3; input;2;0;8;4;1;2 Declaration of variables: VARIABLE 1 VARIABLE 2 VARIABLE 12 index contact@webdyn.com | webdyn.com V1.0 subject to changes | Webdyn © by Flexitron Group...
Page 44
Not supplied action 4 (instant value) 4 (instant value) 8 (alarm) Modbus_VariablesTables={ 1;1;counter1;3;2;1;;;1;0;pulse;4 2;1;counter2;3;2;2;;;1;0;pulse;4 3;1;counter3;3;2;3;;;1;0;pulse;4 4;1;counter4;3;2;4;;;1;0;pulse;4 5;2;output1;1;2;1;;;1;0;;4 6;2;output2;1;2;2;;;1;0;;4 7;2;output3;1;2;3;;;1;0;;4 8;2;output4;1;2;4;;;1;0;;4 9;3;input1;1;2;1;;;1;0;;8 10;3;input2;1;2;2;;;1;0;;8 11;3;input3;1;2;3;;;1;0;;8 12;3;input4;1;2;4;;;1;0;;8 contact@webdyn.com | webdyn.com V1.0 subject to changes | Webdyn © by Flexitron Group...
Page 45
CSV format. This file is compressed in GZ format, then uploaded periodically to the FTP server for subsequent operations. 7.5.1 Filename Syntax The data file uploaded to the FTP server complies with the following format: prefixID_MODBUS_YYMMDD_hhmmss.csv.gz contact@webdyn.com | webdyn.com V1.0 subject to changes | Webdyn © by Flexitron Group...
Page 46
- t i m e _ n ; v a r i a b l e _ 1 _ v a l u e _ n _ D e v i c e N ; v a r i a b l e _ 2 _ v a l u e _ n _ DeviceN;variable_x_value_n_DeviceN contact@webdyn.com | webdyn.com V1.0 subject to changes | Webdyn © by Flexitron Group...
Page 47
Special case: averaged data item: If a data item is configured as Min/Max/Average in the definition file, it will appear in the data file in the following manner: contact@webdyn.com | webdyn.com V1.0 subject to changes | Webdyn © by Flexitron Group...
Page 48
7.5.3 Example 2 Modbus devices, with acquisition every 15 minutes. ADDRMODBUS;1;001 TypeMODBUS;prefixID_MODBUS_TYPE1.ini 12;1;2;3;4;5;6;7;8;9;10;11;12 27/03/13-09:45:00;32;52;5;102;1;0;1;0;0;0;0;0 27/03/13-10:00:00;35;57;5;108;1;1;0;0;0;0;0;1 ADDRMODBUS;2;002 TypeMODBUS;prefixID_MODBUS_TYPE2.ini 6;1 (min);1 (max);1 (avg);2 (min);2 (max);2 (avg) 27/03/13-09:45:00;16;32;26.00;52;58;54.00 27/03/13-10:00:00;4;6;5.50;102;105;103.00 contact@webdyn.com | webdyn.com V1.0 subject to changes | Webdyn © by Flexitron Group...
Page 49
# Id;Name;ReadFctCode;WriteFctCode;StartReg;NbReg;EnableReading; EnableWriting;Option1;Option2 Modbus_RequestsTables={ 1;counter;3;0;0;4;1;2 2;output;1;5;4;4;1;1 3;input;2;0;8;4;1;2 # Definition of variables # Id;ReqId;Name;Type;Signed;Position;Option1;Option2;CoeffA;CoeffB, Unit,Action; Modbus_VariablesTables={ 1;1;counter1;3;2;1;;;1;0;pulse;4 2;1;counter2;3;2;2;;;1;0;pulse;4 3;1;counter3;3;2;3;;;1;0;pulse;4 4;1;counter4;3;2;4;;;1;0;pulse;4 5;2;output1;1;2;1;;;1;0;;4 6;2;output2;1;2;2;;;1;0;;4 7;2;output3;1;2;3;;;1;0;;4 8;2;output4;1;2;4;;;1;0;;4 9;3;input1;1;2;1;;;1;0;;8 10;3;input2;1;2;2;;;1;0;;8 11;3;input3;1;2;3;;;1;0;;8 12;3;input4;1;2;4;;;1;0;;8 contact@webdyn.com | webdyn.com V1.0 subject to changes | Webdyn © by Flexitron Group...
Page 50
27/03/13-09:45:00 32 pulses 52 pulses 5 pulses 102 pulses 27/03/13-10:00:00 35 pulses 57 pulses 5 pulses 108 pulses Status of outputs: OUTPUT1 OUTPUT2 OUTPUT3 OUTPUT4 27/03/13-09:45:00 27/03/13-10:00:00 contact@webdyn.com | webdyn.com V1.0 subject to changes | Webdyn © by Flexitron Group...
Page 51
The alarm file uploaded to the FTP server complies with the following format: prefixID_AL_YYMMDD_hhmmss.csv.gz Where: prefixID: gateway identifier. YYMMDD_hhmmss: timestamp of the archive in the format “year-month-day- hour-minute-second”. contact@webdyn.com | webdyn.com V1.0 subject to changes | Webdyn © by Flexitron Group...
Page 52
The alarm file prefixID_AL_130327_100305.csv.gz was received after a change in the status of inputs input4 and input2 of the device Slave 1. The file contains the following information: 27/03/13-10:01:16;MODBUS;prefixID_MODBUS_TYPE1.ini;Slave 1;12;1 27/03/13-10:01:18;MODBUS;prefixID_MODBUS_TYPE1.ini;Slave 1;10;0 contact@webdyn.com | webdyn.com V1.0 subject to changes | Webdyn © by Flexitron Group...
Page 53
On 27/03/13 at 10:01:16 the variable input4 indexed at 12 on the device named Slave1 switched to 1. On 27/03/13 at 10:01:18 the variable input2 indexed at 10 on the device named Slave1 switched to 0. contact@webdyn.com | webdyn.com V1.0 subject to changes | Webdyn © by Flexitron Group...
Page 54
Value of the parameter, in decimal or ASCII. Acknowledgement file: prefixID_ACK_YYMMDD_hhmmss.csv. The acknowledgement file mirrors the command file, with timestamps added, and the acknowledgement: Date-time;index;MODBUS;indexDevice;indexVariable;value;ack Where ack=OK or ERROR. contact@webdyn.com | webdyn.com V1.0 subject to changes | Webdyn © by Flexitron Group...
Page 55
• Click on Choose file and select the “.pak” file provided by Webdyn. • Click on OK. • The following message is displayed. • Click on “OK” and wait until the file download onto the gateway is complete. contact@webdyn.com | webdyn.com V1.0 subject to changes | Webdyn © by Flexitron Group...
Page 56
• FTP_DirBin= name of the directory containing the new firmware. The gateway will download its new configuration file, then its new firmware, when it next connects to the FTP server. contact@webdyn.com | webdyn.com V1.0 subject to changes | Webdyn © by Flexitron Group...
Page 57
POST data: parameters of the Web Service in the format: parameter1¶meter2... parameterN. The URL is configured via the variable “WebService_Url” in the configuration file. The name of the Web Service can be “Initialization.php” or “confirmation.php”. contact@webdyn.com | webdyn.com V1.0 subject to changes | Webdyn © by Flexitron Group...
Page 58
MAC address format: XX:XX:XX:XX:XX:XX HTTP response: ReturnCode##IDsite## The return codes of the responses from the HTTP server may be: 00: OK 13: MAC-ADR absent -1: Internal server problem contact@webdyn.com | webdyn.com V1.0 subject to changes | Webdyn © by Flexitron Group...
Page 59
ACTION-COMP= list of files involved& RC=0& RC-COMP= confirm.php NSITE=IDsite& Informs the HTTP server that definition files have been uploaded ACTION=UPLOADDEF& to the FTP server. ACTION-COMP= list of files involved& RC=0& RC-COMP= contact@webdyn.com | webdyn.com V1.0 subject to changes | Webdyn © by Flexitron Group...
Page 60
Informs the HTTP server of the current ver-sion of the gateway ACTION=VERSION& firmware. This Web Ser-vice is sent on the first connection following a ACTION-COMP=2.03.01 Aug 1 2011& gateway restart. RC=0& RC-COMP= contact@webdyn.com | webdyn.com V1.0 subject to changes | Webdyn © by Flexitron Group...
Page 61
9.3 Examples of Web Services Requests Upload of a data file: URL/confirm.php;NSITE=IDsite&ACTION=UPLOADDATA&RC=0&RC-COMP= Download of the configuration files IDsite_config.ini and IDsite_var.ini: URL/confirm.php;NSITE=IDsite&ACTION=CONFIGGLOBAL&ACTION-COMP=IDsite_ config.ini;IDsite_var.ini;&RC=0&RC-COMP= Download of a new firmware release: URL/confirm.php;NSITE=IDsite&ACTION=CONFIGBIN&RC=0&RC-COMP= contact@webdyn.com | webdyn.com V1.0 subject to changes | Webdyn © by Flexitron Group...
Page 62
Command file download failed FTP send config file OK: [filename] Upload of configuration file [filename] successful FTP send config file failed: [filename] Upload of configuration file [filename] unsuccessful contact@webdyn.com | webdyn.com V1.0 subject to changes | Webdyn © by Flexitron Group...
Page 63
[filename] unsuccessful FTP send log file OK: [filename] Upload of events journal [filename] successful FTP send log file failed: [filename] Upload of events journal [filename] unsuccessful contact@webdyn.com | webdyn.com V1.0 subject to changes | Webdyn © by Flexitron Group...
Page 64
SMS received:Change GPRS login [login] An SMS to change the APN login was received SMS received:Change GPRS password An SMS to change the APN password was [password] received contact@webdyn.com | webdyn.com V1.0 subject to changes | Webdyn © by Flexitron Group...
Page 65
• SIM PUK: The SIM card is waiting for a PUK code (after three unsuccessful attempts to enter a PIN code). • SIM ERROR: No SIM card has been inserted. • Signal level: Quality of the GSM signal; range 1 to 31. contact@webdyn.com | webdyn.com V1.0 subject to changes | Webdyn © by Flexitron Group...
Page 66
10.3.2 Format of Alarms The uploaded CSV alarm file may contain several alarms from different sources. The entry for a 24 V power loss alarm has the following format: date-time;GATEWAY;info contact@webdyn.com | webdyn.com V1.0 subject to changes | Webdyn © by Flexitron Group...
Page 67
Flashing rapidly Initialization ModBus Power on Initialization ends Flickering Traffic with Modbus equipments Activity LED Flashing rapidly Initialization Modbus Power on Initialization ends Flickering Traffic with Modbus equipments contact@webdyn.com | webdyn.com V1.0 subject to changes | Webdyn © by Flexitron Group...
Page 68
FUNCTION STATUS EXPLANATION Green LED: speed Connection speed 10 Mbps 100 Mbps Orange LED: link Connection No connection activity Connection made Flickering Data being sent or received contact@webdyn.com | webdyn.com V1.0 subject to changes | Webdyn © by Flexitron Group...
Page 69
• Information on the APN configured • SIM card identifier • GSM signal strength (RSSI) • Information on the Ethernet interface (IP, router, DNS, etc.) • Information on the remote FTP server contact@webdyn.com | webdyn.com V1.0 subject to changes | Webdyn © by Flexitron Group...
Page 70
RemoteIpAddr Reserved for use by Webdyn in support mode (up to 15 characters) Log_Port Syslog destination port 2000 Reserved for use by Webdyn in support mode contact@webdyn.com | webdyn.com V1.0 subject to changes | Webdyn © by Flexitron Group...
Page 71
• Turn off the power supply to the unit. • Open the casing of the WebdynModbus to gain access to the configuration DIP switch. • Set DIP switch 2 to ON. contact@webdyn.com | webdyn.com V1.0 subject to changes | Webdyn © by Flexitron Group...
Page 72
• Wait for the unit to restart automatically, after all the LEDs flash simultaneously (around 2 minutes). • Reset DIP switch 2 to OFF. • Close the unit. A factory reset does not delete the collected data. contact@webdyn.com | webdyn.com V1.0 subject to changes | Webdyn © by Flexitron Group...
Page 73
Email: jcabezas@matrix.es District Centre, Janakpurt, 110058 New Delhi Phone: +91.1141519011 Email: purchase-india@webdyn.com PORTUGAL LusoMatrix Lda. Av. Coronel Eduardo Galhardo 7-1ºC 1170-105 Lisbon, Portugal Phone: +351.218162625 Email: comercial@lusomatrix.pt contact@webdyn.com | webdyn.com V1.0 subject to changes | Webdyn © by Flexitron Group...
Table of Contents
Print
Rename the bookmark
Delete bookmark?
Delete from my manuals?
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL