Fault
"E:30 / -80"
"E:36 / -25 / -26"
"E:38 / -25 / -26"
"E:35 / -10"
Voltage under-usage
symbol (double point).
Cause and troubleshooting
The pump cap is not fully screwed in.
Ensure that the pump cap is screwed in all the way
into the appliance. The handle on the pump cap
must be in a vertical position.
Drain pump is blocked.
→ "Cleaning the drain pump", Page 35
Drain pump is blocked.
→ "Cleaning the drum", Page 33
if the fault is displayed again,
→ "Cleaning the drain pump", Page 35
Inlet opening of the rubber gasket is blocked.
→ "Cleaning the intake opening in the rubber gas-
ket", Page 37
The water pressure is low.
No remedial action possible.
The filter in the water inflow is blocked.
Clean the water inflow filter.
The tap is turned off.
Turn on the tap.
The water inlet hose is kinked or jammed.
Ensure that the water inlet hose is not kinked or
jammed.
There is water in the base trough.
Turn off the water tap.
Call the after-sales service.
→ "Customer Service", Page 48
The appliance is leaking.
Turn off the water tap.
Call the after-sales service.
→ "Customer Service", Page 48
The automatic voltage control system detects an un-
authorised voltage under-usage.
No remedial action possible.
Note: If the power supply is stable, the programme
continues to run as normal.
Voltage under-usage may cause extension of a pro-
gramme.
No remedial action possible.
Troubleshooting en
39