Series Description
The Series Connect offers a portfolio for Industrial Data Communication (IDC) for fast Ethernnetwork connectivity and t.
Designed asan ideal solution for industrial applications, connecting Programmable Controllers (CPs), Human Machine
Interfaces (HMIs), Frequency Inverters and supervisory stations running on industrial servers or computers, the Connect
Series brings a selection of switches and media. With an easy installation procedure, DIN rail and wall mounting, and a
robust IP30 standard design for applications in harshenvironments, the Connect Series supports high temperature
variations,which ensures reliable operation at 10/100 Mbps. Thedicionalmente,its alt performance switchingmechanism
meets all requirements for industrial data communication.
Data for Purchase
CET2-0500 Member Items
The packaging of this product containsthe followings itens:
A CET2-0500 Switch
Wall mounting brackets and screws
ET2-0602-M Member Items
The packaging of this product containsthe followings itens:
An ET2-0602-M switch
Wall mounting brackets and screws
ET2-0800 Member Items
The packaging of this product containsthe followings itens:
An ET2-0800 switch
Wall mounting brackets and screws
Altus S. A.
Connect series
Rev: A
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Connect Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for ALTUS Connect Series

  • Page 1 Series brings a selection of switches and media. With an easy installation procedure, DIN rail and wall mounting, and a robust IP30 standard design for applications in harshenvironments, the Connect Series supports high temperature variations,which ensures reliable operation at 10/100 Mbps. Thedicionalmente,its alt performance switchingmechanism meets all requirements for industrial data communication.
  • Page 2: Product Code

    Industrial Communication Connect series Doc. Code: CE125001 Rev: A ET5-0802-M Member Items The packaging of this product containsthe followings itens:  An ET5-0802-M switch  Wall mounting brackets and screws  Manual on CD  RJ45 Console Cable for DB9 Serial...
  • Page 3 Industrial Communication Connect series Doc. Code: CE125001 Rev: A Description of CET2-0500 CET2-0500 is a 5-port s fast Ethernet switch designed to be compact, which makes it the ideal model to fit inside pain and is with limitedspaces such asin machine control boxes and duct assembly rooms. For installations in hostile field environments, suchas vibration machines or duct assembly rooms, the CET2-0500 can be easily mounted directly andon the DIN rail.
  • Page 4 Industrial Communication Connect series Doc. Code: CE125001 Rev: A General Characteristics - CET2-0500 CET2-0500 IEEE 802.3 10BaseT Ethernet Standards IEEE 802.3u 100BaseTX Fast Ethernet Processing Type Store and Forward Technology Protocol CSMA/CD IEEE 802.3x Standard for Data Flow Control, Back-Pressure Mode...
  • Page 5: Physical Dimensions

    Industrial Communication Connect series Doc. Code: CE125001 Rev: A Hardware Description – CET2-0500 Physical Dimensions See below the physical dimensions of the CET2-0500: (L x A x P) is 26mm x 95mm x 75mm Altus S. A.
  • Page 6: Front Panel

    Industrial Communication Connect series Doc. Code: CE125001 Rev: A Front Panel The front panel of the CET2-0500 is show in the image below: CET2-0500 Front Panel Higher View The image below demonstrates the top panel of the CET2-0500, which is equipped with a removable 4-pin block...
  • Page 7: Ethernet Ports

    Industrial Communication Connect series Doc. Code: CE125001 Rev: A LED indicators There are LED indicators located on the front panel of the switch that show the power and network status. Each LED indicator has a different color and has its own meaning, as shown in the table below:...
  • Page 8 Industrial Communication Connect series Doc. Code: CE125001 Rev: A Step 2: Tighten the screw screws to prevent the wires from loosening, as shown below: Block Power Terminal Caution: use only copper conductors (100°C). Tighten the screws at 0.56 N.m. The wire gauge for the block terminal should be 18-20 AWG (0.81mm to 1.02mm).
  • Page 9 Industrial Communication Connect series Doc. Code: CE125001 Rev: A Follow the steps below to learn how to secure the industrial Ethernet switch. Step 1: Use the screws to install the DIN rail holder on the back of the switch. Warning: The torque to tighten the screws on the device is 0.4 Nm.
  • Page 10: Wall Mount

    Industrial Communication Connect series Doc. Code: CE125001 Rev: A Step 5: Make sure the bracket firmly installed on the rail. Step 6: To remove the rail switch, do the opposite of the steps above. Wall Mount Follow the steps below to mount the switch using the wall mount bracket, as shown in the figure below: Remove the DIN rail holder from the switch Warning:"Wall"...
  • Page 11: Installation Steps

    Industrial Communication Connect series Doc. Code: CE125001 Rev: A In the figure below are the dimensions of the wall mount bracket: Dimensions of the wall mount bracket Hardware Installation – CET2-0500 Installation Steps This section explains how to install CET2-0500.
  • Page 12 Look for loose power connections, power outages, or power outage surges.  Contact Altus for technical support service if the issue can't be resolved yet.  If the switch LED indicators are normal and the cables are properly connected, but the packets are not yet transmitted, check the configuration or status of the system Ethernet devices.
  • Page 13 Industrial Communication Connect series Doc. Code: CE125001 Rev: A Description of ET2-0602-M The ET2-0602-M is a 6-port fast Ethernet switch (4 RJ45 ports and 2 Fiber ports) designed to be compact, making it the ideal modelfor fitting inside painand is with limitedspaces suchas in machine control boxes and duct assembly rooms.
  • Page 14 Industrial Communication Connect series Doc. Code: CE125001 Rev: A General Characteristics - ET2-0602-M ET2-0602-M IEEE 802.3 10BaseT Ethernet Standards IEEE 802.3u 100BaseTX Fast Ethernet Processing Type Store and Forward Technology Protocol CSMA/CD IEEE 802.3x Standard for Data Flow Control, Back-Pressure Mode...
  • Page 15 Industrial Communication Connect series Doc. Code: CE125001 Rev: A Hardware Description - ET2-0602-M Physical Dimensions See the image below for the physical dimensions of the ET2-0602-M: (L x A x P) is 30mm x 142mm x 99mm Physical Dimensions of The ET2-0602-M...
  • Page 16: Led Indicators

    Industrial Communication Connect series Doc. Code: CE125001 Rev: A Higher View In the image below is demonstrated the top panel of the ET2-0602-M, which is equipped with a removable 6-pin block connector, for two 12-48Vdc power inputs: ET2-0602-M Top Panel View LED indicators There are LED indicators located on the front panel of the switch that show the power and network status.
  • Page 17 Industrial Communication Connect series Doc. Code: CE125001 Rev: A Fiber Door The Fiber Port of the Type SC connector can operate in Multimode. When connecting Fiber Ports to each other, follow the instructions as illustrated below to make the connection correctly. A wrong connection will cause abnormal operation.
  • Page 18 Industrial Communication Connect series Doc. Code: CE125001 Rev: A Connecting the Fault Alarm Contact The Fault Alarm contact is located in the middle of the block terminal connector as shown in the image below. When inserting the wires, the fault status will be detected, including power failure or connection failure on the port (manageable industrial switch only) and forming a normally open circuit.
  • Page 19 Industrial Communication Connect series Doc. Code: CE125001 Rev: A Mechanical Assembly – ET2-0602-M DIN Rail Assembly The DIN rail holder is factory preinstalled on the switch. If support isn't installed, see the image below to learn how to install it.
  • Page 20 Industrial Communication Connect series Doc. Code: CE125001 Rev: A Step 4: Pull the bracket slightly down the rail, as shown in the image below: Stabilize the switch on the DIN rail Step 5: Make sure the bracket firmly mounted on the rail.
  • Page 21 Industrial Communication Connect series Doc. Code: CE125001 Rev: A In the image below are the dimensions of the wall mount bracket: Dimensions of the wall mount bracket Hardware Installation – ET2-0602-M Installation Steps This section explains how to install the ET2-0602-M:...
  • Page 22  If the power indicator LED does not turn on when the power cord plugged in, the user may be having a problem with the cord. Look for loose power connections, power outages, or power outlet surges.  Contact Altus for technical support service if the problem still cannot be resolved. ...
  • Page 23 Industrial Communication Connect series Doc. Code: CE125001 Rev: A Description of ET2-0800 The ET2-0800 is an 8-port fast Ethernet switch designed to be compact, making it the ideal model to fit inside panels with limited space such as machine control boxes and duct assembly rooms. For installations in harsh field environments, such as in vibrating machines or duct assembly rooms, the ET2-0800 can easily be mounted directly on the DIN rail.
  • Page 24 Industrial Communication Connect series Doc. Code: CE125001 Rev: A industrial environments, the aluminum alloy housing is rigid and complies with the IP30 level of protection. General Features - ET2-0800 ET2-0800 IEEE 802.3 10BaseT Ethernet Standards IEEE 802.3u 100BaseTX Fast Ethernet...
  • Page 25 Industrial Communication Connect series Doc. Code: CE125001 Rev: A RoHS Environmental UL 61010-1, UL61010-2-201, ISA 12.12.01 Safety IEC 60068-2-11, IEC 60068-2-52, IEC 60068-2-60 IPC-CC-830B, MIL-I- 46058C, IEC 61086-2 (Class 2), UL 94, UL 746E ISO 9223 (Class C5- Corrosion Protection Very High, Class CX-Extreme) ANSI/ISA 71.04 (GX-Severe Class)
  • Page 26 Industrial Communication Connect series Doc. Code: CE125001 Rev: A Hardware Description – ET2-0602-M Physical Dimensions See the image below for the physical dimensions of the ET2-0800: (W x H x D) is 30mm x 140mm x 95mm Physical Dimensions of the ET2-0800...
  • Page 27: Ethernet Ports

    Industrial Communication Connect series Doc. Code: CE125001 Rev: A Superior vision The image below shows the top panel of the ET2-0800, which is equipped with a removable 6-pin block connector for two 12-48Vdc power inputs: ET2-0800 Top Panel View LED indicators There are LED indicators located on the front panel of the switch that show power and network status.
  • Page 28 Industrial Communication Connect series Doc. Code: CE125001 Rev: A 1000Base-T Pinout: Crossover Cable Direct Cable Nº / Pin signal Nº / Pin signal Nº / Pin signal Nº / Pin signal 1 / TP0+ 3 / TP1+ 1 / TP0+...
  • Page 29 Industrial Communication Connect series Doc. Code: CE125001 Rev: A should be 18-20 AWG (0.81mm to 1.02mm). Grounding Note: Grounding and routing the wires helps to reduce the effects of noise due to electromagnetic interference (EMI). Make the grounding connection of the screw to the grounding surface before connecting devices. The ground...
  • Page 30: Din Rail Mount

    Industrial Communication Connect series Doc. Code: CE125001 Rev: A Mechanical Assembly – ET2-08000 DIN Rail Mount The DIN rail bracket is pre-installed on the switch at the factory. If support is not installed, see the image below to learn how to install it: Switch back and DIN rail bracket Follow the steps below to learn how to secure the switch.
  • Page 31 Industrial Communication Connect series Doc. Code: CE125001 Rev: A Step 3: After the DIN rail bracket is installed on the back of the switch, insert the top of the bracket into the rail as shown in the image below: Insert the switch into the DIN rail...
  • Page 32 Industrial Communication Connect series Doc. Code: CE125001 Rev: A Step 3: Use the screws to secure the wall mount bracket to the switch. Attention: The torque to tighten the screws on the device is 0.4 N.m. Step 4: Use the hook holes in the corners of the wall mount bracket to secure the switch to the wall.
  • Page 33 Industrial Communication Connect series Doc. Code: CE125001 Rev: A Hardware Installation – ET2-0800 Installation Steps This section explains how to install the ET2-0800: Installation Steps: Step 1: Unpack the switch from the original box Step 2: Make sure the bracket is screwed onto the switch.
  • Page 34 • If the power indicator LED does not turn on when the power cord is plugged in, the user may be having a problem with the cord. Look for loose power connections, power outages, or power outlet surges. Contact Altus for technical support service if the problem still cannot be resolved.
  • Page 35 Industrial Communication Connect series Doc. Code: CE125001 Rev: A Hardware Features: Interface & Performance • All copper ports support Auto MDI/MDI-X function • 6 RJ45 ports and 2 Fiber ports (SC/ST) • Store-and-Forward Switching Architecture • 8k MAC Address Table •...
  • Page 36 Industrial Communication Connect series Doc. Code: CE125001 Rev: A General Characteristics - ET5-0802-M ET5-0802-M IEEE 802.3 10Base-T Ethernet IEEE 802.3u 100Base-TX e 100Base-FX Fast Ethernet IEEE 802.3x Controle de Fluxo IEEE 802.1d STP (Protocolo Spanning Tree) IEEE 802.1w RSTP (Protocolo Rapid Spanning Tree) IEEE 802.1s MSTP (Protocolo Multiple Spanning Tree)
  • Page 37 Industrial Communication Connect series Doc. Code: CE125001 Rev: A IGMP Group 1024 14,880pps for Ethernet port 148,800pps for Fast Ethernet port 1,488,000pps Transfer Rate for Gigabit Ethernet port 6x 10/100Base-T(X), Auto Speed Negotiation, Full/Half Duplex Mode, RJ45 Ports MDI/MDI-X Automatic Connection...
  • Page 38 Industrial Communication Connect series Doc. Code: CE125001 Rev: A Hardware Description - ET5-0802-M Physical Dimensions See the image below for the physical dimensions of the ET5-0802-M: (W x H x D) is 54mm x 142mm x 99mm Physical Dimensions of ET5-0802-M...
  • Page 39 Industrial Communication Connect series Doc. Code: CE125001 Rev: A Superior vision The image below shows the top panel of the ET5-0802-M, which is equipped with a removable 6-pin block connector for two 12-48Vdc power inputs: ET5-0802-M Top Panel View LED indicators There are LED indicators located on the front panel of the switch that show power and network status.
  • Page 40: Ethernet Ports

    Industrial Communication Connect series Doc. Code: CE125001 Rev: A Ethernet ports RJ45 ports automatically identify 10Base-T, 100Base-TX, or 1000Base-T device connections. Auto MDI/MDIX means the switch can connect to another switch or workstation without changing the direct or crossover cabling.
  • Page 41 Industrial Communication Connect series Doc. Code: CE125001 Rev: A Cabling Use CAT 5e 4-pair twisted-pair cable or higher cabling for RJ45 port connections. The cable between the switch and the device (switch, hub, workstation, etc.) must be less than 100m long.
  • Page 42 Industrial Communication Connect series Doc. Code: CE125001 Rev: A Connecting Fault Alarm Contact The Fault Alarm contact is located in the middle of the block terminal connector as shown in the image below. Inserting the wires will detect Fault status including power failure or port connection failure (Manageable Industrial Switch only) and form a normally open circuit.
  • Page 43 Industrial Communication Connect series Doc. Code: CE125001 Rev: A Follow the steps below to learn how to secure the switch. Step 1: Use the screws to install the DIN rail bracket to the back of the switch. Attention: The torque to tighten the screws on the device is 0.4 N.m Step 2: To remove the DIN rail bracket, do the opposite of Step 1.
  • Page 44: Wall Mount

    Industrial Communication Connect series Doc. Code: CE125001 Rev: A Wall Mount Follow the steps below to mount the switch using the wall mount bracket as shown in the image below. Step 1: Remove the DIN rail bracket from the switch by loosening the screws.
  • Page 45 Look for loose power connections, power outages, or power outlet surges. Contact Altus for technical support service if the problem still cannot be resolved. • If the switch LED indicators are normal and the cables are properly connected, but packets are still not being transmitted, check the configuration or status of the Ethernet devices in the system.
  • Page 46 Industrial Communication Connect series Doc. Code: CE125001 Rev: A Description of MET2-0201-M The MET2-0201-M is a 2-port media converter (1 RJ45 port and 1 Fiber port) designed to be compact, making it the ideal model for fitting inside panels with limited spaces such as boxes machine control and duct assembly rooms. For installations in harsh field environments, such as in vibrating machines or duct mounting rooms, the MET2-0201-M can easily be mounted directly on the DIN rail.
  • Page 47 Industrial Communication Connect series Doc. Code: CE125001 Rev: A Reliable Mechanical Design Industrial applications are known for harsh environments and are required to run non-stop. The product is designed for harsh conditions such as high or low temperatures, impacts or vibration. To handle the demands of industrial environments, the aluminum alloy housing is rigid and complies with the IP30 level of protection.
  • Page 48 Industrial Communication Connect series Doc. Code: CE125001 Rev: A Hardware Description - MET2-0201-M Physical Dimensions See the image below for the physical dimensions of the MET2-0201-M: (W x H x D) is 26mm x 95mm x 75mm Physical Dimensions of MET2-0201-M...
  • Page 49 Industrial Communication Connect series Doc. Code: CE125001 Rev: A Front panel The front panel of the MET2-0201-M is show in the image below: MET2-0201-M Front Panel Superior vision The image below shows the top panel of the MET2-0201-M, which is equipped with a removable 6-pin block connector for...
  • Page 50: Dip Switch Setup

    Industrial Communication Connect series Doc. Code: CE125001 Rev: A Green Connected to the network, 100Mbps (SPEED) Connected to the network, 10Mbps Connected to the network, 100Mbps Fiber 100FX Lightenin Green Network is active (LINK/ACT) Not connected to the network LED indicators for the MET2-0201-M DIP Switch Setup There are 6 pins on the front panel DIP switch for LFP (Link Fault Pass) function setting and Transmission control setting.
  • Page 51 Industrial Communication Connect series Doc. Code: CE125001 Rev: A On: Sets Copper Port baud rate to Half-Duplex Off: Sets Copper Port baud rate to Full-Duplex (default) Attention: When changing DIP switch settings, the device must be turned off and on again for the settings to be carried out.
  • Page 52: Fiber Port

    Industrial Communication Connect series Doc. Code: CE125001 Rev: A Fiber port Fiber Port of SC type connector can operate in Multimode. When connecting Fiber Ports to each other, follow the instructions as illustrated below to make the connection correctly. A wrong connection will cause abnormal operation.
  • Page 53 Industrial Communication Connect series Doc. Code: CE125001 Rev: A Attention: Only use copper conductors (70/80ºC). Tighten the screws to 0.56 N.m. The gauge of wires to the terminal block should be 18-20 AWG (0.81mm to 1.02mm). Connecting Fault Alarm Contact The Fault Alarm contact is located in the middle of the block terminal connector as shown in the image below.
  • Page 54 Industrial Communication Connect series Doc. Code: CE125001 Rev: A Mechanical Assembly - MET5-0201-M DIN Rail Mount The DIN rail bracket is factory pre-installed on the media converter. If support not installed, see the image below to learn how to install it: Rear of Media Converter and DIN Rail Bracket Follow the steps below to learn how to fix the media converter.
  • Page 55 Industrial Communication Connect series Doc. Code: CE125001 Rev: A Step 4: Pull the bracket slightly down on the rail as shown in the image below: Stabilize the media converter on the DIN rail Step 5: Make sure the bracket securely mounted to the rail.
  • Page 56 Industrial Communication Connect series Doc. Code: CE125001 Rev: A Step 5: To remove the wall mount bracket, do the opposite of the steps above. Remove the media converter DIN rail bracket In the image below are the dimensions of the wall mount bracket: Wall Mount Bracket Dimensions Altus S.
  • Page 57 Industrial Communication Connect series Doc. Code: CE125001 Rev: A Hardware Installation - MET5-0201-M Installation Steps This section explains how to install the MET2-0201-M: Installation Steps: Step 1: Unpack the media converter from the original box Step 2: Make sure the bracket is screwed onto the media converter.
  • Page 58 Look for loose power connections, power outages, or power outlet surges. Contact Altus for technical support service if the problem still cannot be resolved. If the media converter LED indicators are normal and the cables are properly connected, but packets are still not being transmitted, check the configuration or status of the system's Ethernet devices.