INSTRUCTION MANUAL
www.stifnet.com

USE

®
- The VIGIBELT
CDM80 is a belt alignment control system for buckets elevator. It helps prevent friction between the
strap and the inside of the elevator leg. The VIGIBELT® CDM80 detector must be installed in pairs on the side of
the riser leg of the elevator and just above its foot. If the elevator is more than 20m high, it is then recommended to
add a pair of VIGIBELT® CDM80 just below the head, still on the riser.
- We recommend placing an EAZY> DETEC target (STIF product) every 30 meters on the belt to allow precise
detection by the VIGIBELT® CDM80. The EAZY> DETEC metal target should be installed in place of a plastic
bucket.

DESCRIPTION

®
- The VIGIBELT
CDM80 is composed of two sensors, an calibration tool, a background metal sheet and the fixing
screws.
Possible adjustment for the VIGIBELT
®
- The VIGIBELT
CDM80 is intended to be programmed for detection distances of 15 to 35 mm (with a pitch of 5mm)
between the inside of the lift leg and the target bucket
2X CDM80
PRECAUTIONS
®
The VIGIBELT
CDM80 kit must be installed, connected and put into service only by competent personnel. The
staff must have electrical authorizations, know the regulations and provisions concerning the installation of these
devices, especially for the Ex II3D version integrated in ATEX zones.
- Carry out beforehand an electrical connection study to install the VIGIBELT
power supply and electrical protection, plc control, ATEX zones).
-
Check that the temperature range of use of the VIGIBELT
to your application.
-
Check during the first commissioning of the bucket elevator in the handling phase, that there is no sealing defect
(dust leak) between the sheath of the elevator and the VIGIBELT
-
Bring the bucket elevator or belt conveyor to a stop (off-powored) before any installation or intervention on the
®
VIGIBELT
CDM80 (intervention information to be indicated on the machine).
Z.A. de la lande - 49170 Saint-Georges-sur-Loire - France
Head office, purchasing and factory:
France Export Sales Service:
email:
sales@stifnet.com
- Website:
SAS with a capital of € 800,000 - R.C.S. Angers B 328 876 503 - 84B12 APE 2511Z - VAT number FR 35 328 876 503
- DOC NO. BE0455020-A
®
CDM80
1X CALIBRATION
TOOL
tel: +33 2 41 72 16 80 - Fax +33 2 41 72 16 85
tel.: +33 2 41 72 16 82 - Fax +33 2 41 39 32 12
www.stifnet.com
1X
FLAT BACK SHEET
®
CDM80 (standard electrical diagram,
®
CDM80 (variable according to version) corresponds
®
CDM80.
GB
1/6
M6 SCREWS

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the VIGIBELT CDM80 and is the answer not in the manual?

Questions and answers

Summary of Contents for STIF VIGIBELT CDM80

  • Page 1 VIGIBELT® CDM80 just below the head, still on the riser. - We recommend placing an EAZY> DETEC target (STIF product) every 30 meters on the belt to allow precise detection by the VIGIBELT® CDM80. The EAZY> DETEC metal target should be installed in place of a plastic bucket.
  • Page 2 INSTRUCTION MANUAL – www.stifnet.com - DOC NO. BE0455020-A INSTALLATION - Following figure A, make two symmetrical openings on each side of the elevator (square opening of 112mm + 4 holes on Ø6.5 on a square of 126mm) Careful: obligation to install an EAZY> DETEC metal bucket every 30 meters of belt on elevators equipped with plastic or stainless- steel buckets...
  • Page 3 INSTRUCTION MANUAL – www.stifnet.com - DOC NO. BE0455020-A - First assemble the M6 pan-head screws with the low nuts on the sheath (clamping torque 6N.m). This pre-assembly easier the installation of the VIGIBELT® CDM80 Connect the VIGIBELT® CDM80 according to the electrical diagram B or C: NC detector = positive safety, permanent control of the correct functioning of the sensor ...
  • Page 4 INSTRUCTION MANUAL – www.stifnet.com - DOC NO. BE0455020-A ® Define the detection range of VIGIBELT CDM. To do this, first identify the safety zone that corresponds to the minimum distance that the strap must never cross during a setback defect. Then identify the distance between the edge of the strap and the edge of the metal target (Bucket or EAZY DETECT).
  • Page 5 INSTRUCTION MANUAL – www.stifnet.com - DOC NO. BE0455020-A After the detection distance learning operation, you should check that the VIGIBELT® CDM80 is in mode "1" in normal operation and in mode "2" in the presence of a metal target (see LED status below). 1_Normal operation: GREEN DIODE ON AND ORANGE ON (contact closed) 2_Object in the detection field: GREEN DIODE ON AND ORANGE Off (open contact)
  • Page 6 (stainless steel, electrical equipment, seal, etc.). ® In the event that the VIGIBELT CDM80 kit is used, controlled, under conditions contrary to the precautions described in this instruction manual, STIF declines all responsibility for damage caused to man, animal, environment, material property.

Table of Contents