Download Print this page
Full Gauge TO-712F Quick Start Manual
Full Gauge TO-712F Quick Start Manual

Full Gauge TO-712F Quick Start Manual

Oven time and temperature controlle

Advertisement

Quick Links

Have this manual in your hand
using the FG Finder app.
BEFORE INSTALLING THE CONTROLLER, WE RECOMMEND THAT YOU FULLY READ THE INSTRUCTION
MANUAL TO PREVENT POSSIBLE DAMAGE TO THE PRODUCT.
THROUGH CONTINUOUS DEVELOPMENT, FULL GAUGE CONTROLS RESERVES THE RIGHT TO CHANGE
THIS MANUAL INFORMATION AT ANY TIME WITHOUT PRIOR NOTICE.
THIS CONTROLLER IS NOT RESPONSIBLE FOR SAFETY WITH RESPECT TO ANY FLAME SENSOR, GAS
VALVE, OR SPARK IGNITER OF WHICH NEED TO HAVE SAFETY CERTIFICATES (RECOGNIZED IGNITION AND
GAS MODULE) IN ITS APPLICATION FOR FINAL USE. THE FLAME SENSOR, THE GAS VALVE OR SPARK
IGNITER IN THIS CONTROL WILL BE CONSIDERED SEPARATELY FROM THE THERMON CONTROLLER.
1. DESCRIPTION
Thermostat and timer for the automation of forced convection ovens. This model provides control over gas,
electric, or wood powered ovens, configured through the setup menu. TO-712F also controls steam injection
and lighting in the oven, and has an internal audible alarm (buzzer) that signals, for example, the end of the
roasting process. It also allows using an external audible alarm and selecting the language of its main messages,
thus improving the user experience. The ThermON line is developed and produced with high-quality raw
materials and stands out for its unique and distinctive design and intuitive, user-friendly interface to facilitate
operation and configuration. It offers a functions lock feature to prevent third parties from changing the
parameters, air-tight front panel that provides high protection against the entry of dirt and moisture, and more.
Product conforming to UL Inc. (United States and Canada).
2. APPLICATIONS
Baking ovens, stoves;
3. TECHNICAL SPECIFICATIONS
Power supply / Approximate consumption
Operating temperature / Control temperature
Temperature sensor
Resolution
Digital Input
Flame sensor
Relay outputs
External audible alarm (buzzer) outputs
Product dimensions / Cutout dimensions (mm)
Operating humidity
Ratings outputs for UL Applications
1 A Resistive,100,000 Cycles
0.5 A Pilot load, 100,000 Cycles
Resistance 1 / Gas 1 / Alarm 1
1/8 HP, 100,000 Cycles
1 A General purpose, 100,000 Cycles
1/8 HP, 30,000 Cycles
Steam valve / Ignition
0.5 A Pilot load, 30,000 Cycles
1 A General purpose, 100 Cycles
Lightbulb
1 A Tungsten, 30,000 Cycles
4. INTRODUCTION
Lower display: Indicates the cooking time or
parameter configuration;
Heating on indication
LED;
Ignition output on
indication LED;
Timer activated LED
TO-712F
indicator;
Steam output on LED
indicator;
SET
Q u i c k t o u c h :
T e m p e r a t u r e a n d
cooking time adjustment;
SET
Press and Hold: Access to the
advanced configuration;
Quick touch: Turns the lightbulb
output on and off
Quick touch: Steam activation;
Press and Hold: Steam activation
time adjustment;
* When the stand-by mode is enabled (I08 = YES)
TO-712F
OVEN TIME AND
TEMPERATURE CONTROLLER
Heating
Steam
Lighting
Buzzer
TO712F: 85~240Vac ± 10% (*) (50-60Hz) / 10VA
TO712FL: 12~24Vac/Vdc + 10% / 10VA
0 to 131°F (0 to 55°C) / 14 to 932°F (-10 to 500°C)
Type J or K thermocouple (sold separately)
1ºC / 1ºF
E1: door micro switch input
E2 : flame sensor input
4 relay outputs: 5 (3)A / 250Vac 1/8HP
12Vcc / 30mA (max)
75 x 75 x 100 (WxHxD) / 67.2 x 67.2
10 to 90% UR (without condensation)
TO712F
TO712FL
240 Vac
24Vac / Vdc
240 Vac
24Vac / Vdc
240 Vac
24Vac / Vdc
240 Vac
24Vac / Vdc
240 Vac
24Vac / Vdc
240 Vac
24Vac / Vdc
240 Vac
24Vac / Vdc
240 Vac
24Vac / Vdc
Upper display: Indicates the temperature
measured by the sensor or parameter
configuration;
Te m p e r a t u r e u n i t s L E D
indicator;
Functions lock LED indicator;
Lightbulb output on LED
indicator;
Quick touch: Decreases
parameter value when in
programming mode ;
Press and Hold: Turns
the controller's stand-
by on and off;
Quick touch: Increases parameter value
when in programming mode;
Quick touch: Timer activation;
KEY FUNCTIONS
SET
Each key has an LED to indicate its
LED
function. When the LED is on, it
TECLA
indicates that the key is active and
can be pressed.
IP 65
FRONT
Timer
Functions
Serial
Protection
Block
programming
level
5. INSTALLATION CONFIGURATION
Access the installation configuration menu by pressing the
[Func]is displayed. When [CoD] is displayed press the
< or > keys to enter the access code 231, and press
Use the < or > keys to select the desired function. The value can be edited with a quick touch on the
Use the < or > keys to change the value and press the
configured value and return to the functions menu. To leave the configuration menu and return to the normal
operating mode (temperature indication), press
5.1 Installation setup table
FUN
FUNCTION
Access Code (231)
[CoD]
Oven type selection
[i01]
Temperature sensor type
[i02]
U n i t s e l e c t i o n o f
[i03]
temperature
Language selection
[i04]
Enable external audible
[i05]
alarm (buzzer)
I n t e r n a l a u d i b l e a l a r m
[i06]
(buzzer) volume
Door digital input signal type
[i07]
Enables stand-by oven
[i08]
functionality
6. OPERATION
6.1 Oven: electric
In this operating mode the controller keeps the heating output on until the oven reaches the oven temperature
setpoint (SP). The heating output will be activated again when the temperature drops below the setpoint minus
the hysteresis (F04).
6.2 Oven: gas
In this operating mode the controller automates / monitors the flame ignition and thus the heating of the oven
through the activation of the gas output, ignition module, and flame sensor input. The controller keeps the heating
on until the oven reaches the oven temperature setpoint (SP).
Heating will be activated again when the temperature drops below the setpoint minus the Hysteresis (F04). The
controller permanently monitors the flame sensor to ensure the safe operation of the gas-fired oven. In this way, if
there are any abnormalities, errors Er4 - Flame Sensor shorted with the burner and Er5 - Lack of Flame are
indicated. For more information, check item 9 (Signaling).
6.3 Oven: wood
In this operating mode the heating output works as an upper threshold alarm, indicating when the temperature
exceeds the value adjusted in Oven Temperature setpoint (SP). The audible alarm is also activated to warn the
user about the overheating. The output and audible alarm are switched off when the temperature drops below the
Oven Temperature setpoint (SP) minus the Hysteresis (F05) or when the
pressed.
6.4 Default Mode (standard)
In this operating mode the controller performs the gas type control, however the flame sensor is ignored and the
controller will not monitor flame presence. The controller will not detect errors Er4 - shorted flame sensor and Er5
- out of gas, resulting in an operation with less safety. Note: The Default Mode (standard) of operation is available
only when the type of oven is adjusted as gas. To execute this operating mode, check item 7.4 Enable Default
(standard) Mode of operation.
IN THIS OPERATING MODE THE FLAME SENSOR IS IGNORED AND THE CONTROLLER WILL
NOT DETECT THE PRESENCE / LACK OF FLAME, BEING ESSENTIAL FOR THE OPERATOR TO
PAY SPECIAL ATTENTION TO THE CONTROL OF THE OVEN IN ORDER TO PREVENT GAS
ACCIDENTS.
dddd
SET
dset
key again (quick touch). Use the
SET
dddd
SET
(quick touch) again when ready.
SET
dsse
key with a quick touch when ready to save the
(press and hold) until [----]is displayed.
dddd
SET
DESCRIPTION
Required when you want to change
installation setup parameters.
Selects the control type of the oven:
[ELE,]= Electric Oven
[GAS,]= Gas-fired Oven
[LEN,]= Wood-fired Oven
Defines the type of temperature sensor to
be used with the controller.
Selects the temperature unit the controller
will use for its operation.
Selects the language the controller will use
to display messages:
[Port]= Portuguese
PORT ESP
[,EnG]= English
[,ESP]= Spanish
Enables or disables the external audible
alarm (buzzer). If enabled, the internal OFF
audible alarm (buzzer) will be disabled.
Selects the sound intensity of the internal
audible alarm (buzzer).
[Min,]= low volume
[Med,]= medium volume
[HiGh]= high volume
[,NO,]- normally open contact (NO)
[,NC,]- normally closed contact (NC)
Enables stand-by mode (switching off
control functions).
dddd
SET
key in the controller's front panel is
E251415
key for 4 seconds until
dddd
SET
key.
MIN MAX UNIT DEFA
-
0
9999
0
-
ELE LEN
GAS
-
tc_J tc_H
tc_J
-
ºC
ºF
°C
-
PORT
-
OFF ON
OFF
-
MIN HIGH
HIGH
-
NO
NC
NO
-
NO
YES
NO

Advertisement

loading
Need help?

Need help?

Do you have a question about the TO-712F and is the answer not in the manual?

Questions and answers

Summary of Contents for Full Gauge TO-712F

  • Page 1 Thermostat and timer for the automation of forced convection ovens. This model provides control over gas, Required when you want to change electric, or wood powered ovens, configured through the setup menu. TO-712F also controls steam injection Access Code (231)
  • Page 2 FUNCTION DESCRIPTION UNIT DEFA 7. OPERATIONS - BASIC LEVEL The controller has easy access to resources that are relevant to the user of the oven. The temperature difference to switch on 7.1 Adjustment of oven temperature and timer Oven temperature differential the heating output.
  • Page 3 The [F18] OFF CYC Measure: steam is activated after the time set in F19 has elapsed. Contact Full Gauge Controls. [CYC,]Cyclic: injects steam in cycles using the times configured in [UAon] and [Uaof]. Measure: Contact Full Gauge Controls.
  • Page 4 WARRANTY - FULL GAUGE CONTROLS Products manufactured by Full Gauge Controls, as of May 2005, have a two (2) - year warranty directly with the factory and one (1) year before the reseller network, counted as of the date of consigned sale as stated on the invoice. After this said year before the reseller network, the warranty shall continue to be executed if the instrument is sent directly to Full Gauge Controls.

This manual is also suitable for: