4. Network Bus type: ≦ Valid Distance 1200Meters Device N1 RS485 RS232 T X D R X D P O WER A P3 0 A R S2 3 2 TO RS 4 8 5 C ON VE RTER AP30 相容電腦 ……...
5. TCP/IP converter setting 5.1 Network specification ' TCP/IP Converter : Change TCP/IP converter s default IP as same as the PC s network segments before setting its network set ting. The ne twork speci fication of TCP/IP converter and the PC is as below: (1).
Page 6
※ Standard wiring of RJ45 connector: From left to right: (1) braided white and orange, (2) orange, (3) braided w hite and green, (4) blue, (5) braided white and blue, (6) green, (7) braided white and brown, (8) brown . Crossover wiring of RJ45 connector : Connector A: (1) braided white and orange, (2) orange, (3) braided white and green, (4) blue, ...
5.2 Before setting: Construct all network settings first. Get the PC's IP first and setting TCP/IP as the same network segment. The steps are as below: 】-> 【 】 【 】 -> 【 】-> 【 (1).In MSDOS mode: Start Enter command Enter ...
Page 8
【 】 ' 【 】 (3). Use attached d isc s ETM.EXE to set TCP/IP Converter s First IP Run ETM.EX E to list LAN s TC P/IP Converter. Close all existing fir ewall software ' in or der to receive TCP/IP Converter s response packages. 】 ...
5.3 Setting TCP/IP Converter Use browser to enter to TCP/IP Converter's setting page when the IP is set. h t t p : / / 1 9 2 . 1 6 8 . 1 0 . 2 5 0 (1). Enter and the following page will appear as below. ...
Page 10
TCP/IP Conv erter's IP Address IP address Su bnet mask Subnet Mask(defau lt 2 55. 255.255.0) Gateway Ad dr ess Gateway address Auto; set as AUTO Network link speed DHCP client Disable(Set I P as reser ved at DHCP Server Com if DHCP is activated ) ...
6. Example 1: Using ST680 and its software to demonstrate as ot her model's setting steps will be the same as well. Construction: Software and ST680 are not at the same network segment. 【 】【 】 (1).Setting TCP/IP Co nverter at 203.70.1.x. Follow the steps at 1 2 to set TC P/IP ...
Page 12
(3). Enter Update to refresh. The following page will appear as below: The page remains as TCP/IP Converter and it is at 203.70.2.x network segment. It has to be installed at 203.70.2.12 in order to enter to setting page. ※ Browser will ...
Page 13
' (5)Set ST680 s communication interface to this TCP/IP converter in Reader Settin g. (6)All communication from both sof tware and ST 680 are through network to TCP/IP Converter and vice versa when all settings are set. ...
7. Trouble shooting: 1.Unable to find AP60 ' s IP in ETM program. (a)C heck if both computer and AP60 are at the same segment. Please refer to Converter setting (Step 1). (b)Close all firewalls available to prevent blocking of package sending. (c)Try default IP(PING 192.168.10.89) to check if any responses when the above steps ...
Page 15
(e)C heck if access control or time attendance software is set correctly. Please check the communication inter face which included IP, Port, Communication (TCP or UDP). (f)Check if software s reader number and commun ication interface are selected correctly. ...