Page 2
Find out if you are in a Smoke Control Area by contacting your Local Authority. The Inset Chevin 5 has been fitted with a permanent bypass that prevents closure of the secondary air slider. Removal of this will lead to the appliance potentially causing smoke emissions. Without the permanent bypass in place the appliance is not an exempt appliance and so may leave the householder liable for a fine up to £1000.
OMPETENT ERSONS CHEME manufactured in accordance with BS8423 – Parkray Stoves recommend that this stove is Fireguards for use with solid fuel appliances. installed by a member of an accredited competent persons scheme e.g. HETAS. It is possible to fire the stove beyond its design capacity.
If you have any doubts about the suitability of your before installing this appliance. Parkray Stoves Ltd chimney, consult your local dealer/stockist. cannot be held responsible for any fault arising through incorrect use or installation.
at least 300mm in front of the stove and 150mm Flue Draught at the sides, and should be in accordance with the If the flue draught exceeds the recommended current building regulations. maximum, a draught stabiliser must be fitted so that the rate of burning can be controlled and to In all instances the hearth and fireplace recess prevent over firing.
PPLIANCE IMENSIONS Remove the catch bar / front plate by lifting the right-hand side until it will clear the opening and remove. Remove the grate bars by lifting them away from the cam bar and pulling forward out of Removing Internal Components the rear grate support.
Page 7
5. Remove the cam bar by firstly sliding it to the 8. Remove the ash barrier by sliding out of the right until the left hand end is clear of the stove. hole. 9. Remove the baffle by lifting and tilting one edge so it can be lowered into the firebox and removed.
11. Remove the upper rear brick by lowering it 14. Remove the lower rear brick by tilting the top down into the firebox and out. edge into the firebox and lifting out. Installing the Stove 1. Unpack the stove. 2. Remove internal components. 12.
WARNING – This appliance will be hot when in operation and due care should be taken. The supplied operating tool or gloves may be used to open the door and operate the air controls. EROSOLS Do not use an aerosol spray on or near the stove when it is alight.
OCOMOTIVE RATE the fuel and stove to cool before attempting to Your Parkray Stove is fitted with a locomotive type relight the fire. grate. So that de-ashing can be carried out cleanly and easily, it is riddled from the outside of the N.B.
Clean Air Act requirements. produce a satisfactory heat output. The Inset Chevin 5 has been recommended as Only authorised smokeless fuels may be used in suitable for use in Smoke Control Areas when smoke control areas.
Page 12
Rope - Check the rope around the door. If rope is such as during the spring and summer months, a becoming detached, use Parkray Stoves rope glue competent person should check the chimney for to reattach it. If the rope is in a poor condition, a potential obstructions before lighting the stove i.e.
Primary Air Valve – The primary air valve can be Trouble Shooting removed by lifting the handle until the locating pin is released and pull out of the stove. Check that – To install the primary air valve slide the valve in ...
Need help?
Do you have a question about the Inset Chevin 5 and is the answer not in the manual?
Questions and answers