SPECIFICATIONS COMPATIBLE WITH THE FOLLOWING OPERATORS: - MGJ / H / GH / FDO-A / FDO-B / FDO-A10 / MG / SG NOT COMPATIBLE WITH OTHER (RF) RADIO FREQUENCY DEVICES TRANSMITTER ENCLOSURE MATL:....POLYCARBONATE ENCLOSURE COLOR:...BLACK ENCLOSURE RATING:..NEMA 4 OPERATING TEMP:....-25° F TO 120° F OPERATING FREQUENCY:..315 Mhz MAX OPER DISTANCE:..50 FT POWER:........9 VOLT LITHIUM BATTERY...
THEORY OF OPERATION GENERAL DESCRIPTION: The Phantom Edge is a self monitoring wireless (RF) sensing edge system. A special communication protocol between the transmitter and receiver allow for additional signals (other than edge activation) to be sent, such as battery condition and periodic communication checks.
Page 4
5) Be sure that the battery strap is connected and insert the lithium ion 9 Volt battery into the cover of the unit, and replace the cover. The green LED light should light indicating that the unit is functioning properly. 2 - Wire 4 - Wire Connections...
Page 5
START UP / TESTING PROCEDURES RECEIVER INITIAL POWER UP: (ON OPERATOR) The unit will be in "Supervised Mode": Constant pressure required on door CLOSE control - 2 LED's under the label will be lit. Hold closed door control: - (D3) "Transmitter Awake" (GREEN) LED will blink when edge is pressed. - (D8) "Signal Acquired"...
Open door several feet - Verify that unit is still in "Supervised Mode". Constant pressure required on door CLOSE control. Reconnect sensing edge to Transmitter. Unit will switch to "Normal Mode". - (D6) "Normal Mode" (GRN) LED will light. Door now requires momentary contact for CLOSE control.
Page 7
DOOR WON'T CLOSE OR REVERSES TO FULL OPEN WHEN IT ATTEMPTS TO CLOSE: 1) Receiver has no power and the Safety Edge relay output is "closed" as a result. - Ensure that a STEADY 24 VOLTS are present; if DC is used, the red lead must be "positive" polarity.
Page 8
TO TEST FOR A RF SHORT-RANGE PROBLEM BETWEEN THE TRANSMITTER AND THE RECEIVER: For a BRIEF TEST, turn on the transmitter's test mode switch, #8, and activate the safety edge to initiate a transmission. The transmitter will come on and stay on until the switch #8 is turned back off for normal operation.
Page 9
LABEL AND MANUAL INFORMATION 1) Labeling Requirement In accordance with the Section 15.19 of FCC Rules, a permanently attached label shall be affixed to every product in a conspicuous location with the following statement: "This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: 1) This device may not cause harmful interference, and 2) this device must accept any interference received, including interference that may cause undesired operation."...
Page 11
LIFTMASTER GH/H WIRING DIAGRAM WIRE NUT FROM TRANSFORMER WIRE NUT (FIELD INSTALLED) (REMOVE) ORANGE BROWN GREEN BLUE YELLOW BLACK PHANTOM EDGE RECEIVER...
Page 12
LIFTMASTER MGJ - SINGLE PHASE WIRING DIAGRAM WIRE NUT (FIELD INSTALLED) (REMOVE) BROWN ORANGE BLACK GREEN PHANTOM EDGE RECEIVER...
Page 13
LIFTMASTER MGJ - 3 PHASE WIRING DIAGRAM WIRE NUT TRANSFORMER (FIELD INSTALLED) WIRE NUT RED (REMOVE) ORANGE BLACK BLUE GREEN YELLOW PHANTOM EDGE RECEIVER...
Page 14
FDO-A/FDO-B OPERATOR WIRING DIAGRAM AUX TERMINAL BLOCK J2 CIRCUIT BOARD TERMINALS BROWN BLACK PHANTOM EDGE RECEIVER...
Page 15
MICANAN GH/H WIRING DIAGRAM (REMOVE) WIRE NUT (FIELD INSTALLED) ORANGE YELLOW GREEN BLUE BLACK PHANTOM EDGE RECEIVER...
FDO-A10 WIRING DIAGRAM WALL MOUNTED CONTROL PANEL WIRE NUT (FIELD INSTALLED) YELLOW FROM TERMINAL 14 ON CLOSE CONTACTOR GREEN ORANGE BLACK BLUE BROWN PHANTOM EDGE RECEIVER...
Page 17
COOKSON MG & SG SERIES OPERATOR WIRING DIAGRAM WALL MOUNTED CONTROL PANEL BLACK GREEN BROWN ORANGE BLUE PHANTOM EDGE RECEIVER...
Need help?
Do you have a question about the Phantom Featheredge 6,225,768 and is the answer not in the manual?
Questions and answers