WARNING: IF THE INFORMATION IN THESE INSTRUCTIONS
ARE NOT FOLLOWED EXACTLY, A FIRE OR EXPLOSION MAY
RESULT , CAUSING PROPERTY DAMAGE, PERSONAL INJURY,
OR LOSS OF LIFE.
-
DO NOT STORE OR USE GASOLINE OR OTHER
FLAMMABEL VAPORS AND LIQUIDS IN THE VICINTY OF
THIS OR ANY OTHER APPLIANCE.
-
WHAT TO DO IF YOU SMELL GAS?
DO NOT TRY TO LIGHT ANY APPLIANCE
DO NOT TOUCH ANY ELECTRICAL SWITCH; DO NOT
USE ANY PHONE IN YOUR BUILDING.
IMMEDIATELY CALL YOUR GAS SUPPLIER FROM A
NEIGHBOR'S PHONE. FOLLOW THE GAS SUPPLIERS'
INSTRUCTIONS.
IF YOU CANNOT REACH YOUR GAS SUUPLIER, CALL
THE FIRE DEPARTMENT.
-
INSTALLATION AND SERVICE MUST BE PERFORMED BY A
QUALIFIED INSTALLER, SERVICE AGENCY OR GAS
SUPPLIER.
INSTALLER: Leave this manual with appliance
CONSUMER: Retain this manual for future reference.
Installation & servicing of this appliance MUST be performed by a qualified NFI certified technician.
MASSACHUSETTS: The piping and final gas connection must be performed by a licensed plumber gas fitter in
the state of Massachusetts.
Modern Gas Fireplaces – Linear Fireplaces
FLARE
FIREPLACES | POWER VENT INSTALLATION MANUAL
[SIT CS7 SYSTEM] HIGH VOLTAGE VERSION 5.7
NOTICE

Advertisement

Table of Contents
loading

Summary of Contents for Flare Fireplaces CLASS 2901 84

  • Page 1 WARNING: IF THE INFORMATION IN THESE INSTRUCTIONS ARE NOT FOLLOWED EXACTLY, A FIRE OR EXPLOSION MAY RESULT , CAUSING PROPERTY DAMAGE, PERSONAL INJURY, OR LOSS OF LIFE. DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABEL VAPORS AND LIQUIDS IN THE VICINTY OF THIS OR ANY OTHER APPLIANCE.
  • Page 2: Table Of Contents

    CONTENTS SAFTEY INFO AND WARNINGS ..............................3 FLARE FIREPLACES – FRAMELSS IN EVERY WAY ..........................4 SAFETY ......................................4 MANUAL MODEL LIST & INFORMATION............................4 POWER VENTING OVERVIEW ............................... 5 POWER VENT DRAWINGS ................................5 HORIZONTAL END OF LINE POWER VENT DRAWING ........................... 5 HORIZONTAL END-OF-LINE POWER VENT FRAMING DIMENSIONS .....................
  • Page 3: Saftey Info And Warnings

    SAFTEY INFO AND WARNINGS WARNING! • Series, in Canada. • This appliance is only for use with the type(s) of gas indicated on the rating plate. A conversion kit is supplied with the appliance. • At High Altitude • result causing property damage, personal injury, or loss of life.
  • Page 4: Flare Fireplaces - Framelss In Every Way

    To simplify the installation and operation, all models above share the same gas valve system, remote, gas connection, glass type. All warnings and instructions apply to all models. Flare Fireplaces Power Vent system must only be connected to M&G 3x5 venting system.
  • Page 5: Power Venting Overview

    All three Flare Power Vent systems can be installed to include 8 elbows and run up to 100ft vent run. A minimum length of 12ft venting is required between the Fireplace and the PV, Flare Fireplaces sizes 30”-70”. A minimum length of 15ft, Flare sizes 80”-100”, is required between the fireplace and the PV.
  • Page 6: Horizontal End-Of-Line Power Vent Framing Dimensions

    HORIZONTAL END-OF-LINE POWER VENT FRAMING DIMENSIONS ROUGH OPENING CUT-OUT DIMENSIONS: 13 ½ W x 14 ½ H P a g e...
  • Page 7: Horizontal Power Vent Parts List

    HORIZONTAL POWER VENT PARTS LIST HORIZONTAL POWER VENT PART LIST: ITEM NUMBER PART Name DESCRIPTION W-F-08 PV External Cover W-F-14 PV Board Cover Draft Switch HUBA control to measure fan pressure Elec. Holder Electrical wiring holder Motor inner cover Internal cover motor Exhaust Blower Main Exhaust Fan Housing of Exhaust Blower...
  • Page 8: Vertical End Of Line Power Vent Drawing

    VERTICAL END OF LINE POWER VENT DRAWING ROOF Exhaust Outlet 110V AC Cable P a g e...
  • Page 9 P a g e...
  • Page 10: Vertical Power Vent Parts List

    VERTICAL POWER VENT PARTS LIST VERTICAL POWER VENT PARTS LIST: ITEM NUMBER PART NUMBER DESCRIPTION Housing of Exhaust Blower - Vertical The whole block for vertical power vent Fan | 03 + 04 Main Fan Holder Exhaust Blower Main Exhaust Fan Fan | 08 Inner upper cover for exhaust outlet Draft Switch...
  • Page 11: In-Line Power Vent Drawing

    IN-LINE POWER VENT DRAWING PLEASE NOTE THAT THE INLINE POWER VENT MUST BE MOUNTED TO A STRUCTURE AND CANNOT JUST FLOAT USING THE VENT PIPE 11 | P a g e...
  • Page 12: In-Line Power Vent Parts List

    IN-LINE POWER VENT PARTS LIST IN-LINE POWER VENT PARTS LIST: ITEM NUMBER PART Name DESCRIPTION FanExNet External Cover C-Fan Cooling Fan Exhaust Blower Main Fan Draft Switch (HUBA Control) Pressure Switch FanExDish Electrical Wiring Holder House of Exhaust Blower In-Line In-Line Whole Block Part List ITEM NUMBER...
  • Page 13: Vent Adapter Conversion

    VENT ADAPTER CONVERSION In the event a fireplace is shipped with a standard collar and needs to be converted to support a CVS 3x5 collar, follow the steps below: 1. Remove the 4x6/5x8 Vent adapter from the top of the fireplace as shown in the pictures below: 13 | P a g e...
  • Page 14 2. Install 3x5 Vent adapter: a. Attach the 3inch Female (inner) part first as shown in step1, then tighten the screws as shown in step 2. b. Use 3mm ceramic fiber paper to isolate the vent adapter as shown in steps 1 and 4. c.
  • Page 15 3. Place the 5 Inch Male Adapter in place and tighten down screws to secure to unit. 15 | P a g e...
  • Page 16: Clearances To Power Vent

    Minimum 18-inch x 18-inch access panel required for service. b. The Flare Fireplaces Power Vent must be in an area with a minimum 8 cubic feet of free air space to keep the component operating temperature cool. In addition, the access panel must be louvered to allow for a minimum of 75 sq. inches of free air space.
  • Page 17: Multiple Vertical Termination Points

    MULTIPLE VERTICAL TERMINATION POINTS Exhaust Outlet • If using decorative cap cover/s, this distance may need to be increased. Refer to the installation instruction supplied the decorative cap cover. • In a staggered installation with both gas and wood or fuel oil termination, the wood or fuel oil termination cap must be higher than.
  • Page 18: Vent Termination Clearances

    VENT TERMINATION CLEARANCES ^12 inches (30 cm) min. Clearances above grade, veranda, porch, deck, or balcony 12 inches (30 cm) min. Clearance to window or door that may be opened 12 inches (30 cm) min. Clearance to permanently closed window recommended to prevent condensation on window 24 inches (76 cm) min.
  • Page 19: Vent Restrictor Setup

    RESTRICTOR POSITION NEEDS TO BE CLOSED MORE IF THE FLAME HAS THE FOLLOWING CHARACTERISTICS: • Flame height is low. • Flame has excessive movement DOCUMENT ANY CHANGE TO THE RESTRICTOR SETTING CONTACT FLARE FIREPLACES FOR SUPPORT IF NEEDED 19 | P a g e...
  • Page 20: Power Vent Electrical Connection

    POWER VENT ELECTRICAL CONNECTION • All High Voltage Flare Fireplaces PV systems are connected to the Fireplace with 14|3 AWG 4 wire cable Stranded CU MC (Metal Clad) armored Cable. 3 are used to power the PV and one is used to return signaling when vacuum switch engages.
  • Page 21 Power Vent & SK Power example Fireplace Board PV cable Power Vent 4 wire cable 21 | P a g e...
  • Page 22: Sit Proflame 2 Connections

    SIT PROFLAME 2 CONNECTIONS 22 | P a g e...
  • Page 23: Fireplace Electrical Drawing (With Power Vent - Sit Proflame Ii)

    FIREPLACE ELECTRICAL DRAWING (WITH POWER VENT – SIT PROFLAME II) High Voltage Wire. Green, Black, White, 23 | P a g e...
  • Page 24: Power Vent Electrical Wiring Drawing

    POWER VENT ELECTRICAL WIRING DRAWING Connect high voltage cable and match the colors on the terminals between the PV harness. (White to white, black to black, green to green, red to red) 24 | P a g e...
  • Page 25: Double Glass Board And Fan Switches

    DOUBLE GLASS BOARD AND FAN SWITCHES FAN BYPASS SWITCHES & LEDs (***NUMBER OF FANS CAN CHANGE BASED ON MODEL SIZE***) The dipswitches (DSW1&DSW2), in the “FAN BYPASS” area of the Double Glass Board, are used to determine what fans will be monitored by the board, verifying all fans are indeed working properly before allowing the fireplace burner to start.
  • Page 26: Starting Unit

    (burner) specific. Use the tables below to calculate the restrictor setting. A minimum length of 12ft venting is required between the Fireplace and the PV, Flare Fireplaces sizes 30”- 70”. A minimum length of 15ft, Flare sizes 80”-100”, is required between the fireplace and the PV. Elbows do not count towards required minimum length.
  • Page 27 FLARE-50 (FLARE-FF, FLARE-ST, FLARE-RC, FLARE-LC, FLARE-DC, FLARE-RD) Run Length Restrictor Setting Burner Type Unit Type 12--28 Flare 50 28--40 Flare 50 40--52 Flare 50 52--64 Flare 50 64--76 Flare 50 76--88 Flare 50 88--100 Flare 50 FLARE-60 (FLARE-FF, FLARE-ST, FLARE-RC, FLARE-LC, FLARE-DC, FLARE-RD) Run Length Restrictor Setting Burner Type...
  • Page 28: Connecting 3X5 Pipe

    FLARE-100 (FLARE-FF, FLARE-ST, FLARE-RC, FLARE-LC, FLARE-DC, FLARE-RD) Run Length Restrictor Setting Burner Type Unit Type 12--28 Flare 100 28--40 Flare 100 40--52 Flare 100 52--64 Flare 100 64--76 Flare 100 76--88 Flare 100 88--100 Flare 100 CONNECTING 3X5 PIPE The Flare Power Vent system uses DuraVent 3x5 CVS vent system. The DuraVent CVS vents includes a lock system and a silicone gasket on every side of the vent.
  • Page 29: Replacement Parts

    REPLACEMENT PARTS See below for flare replacement part list. • Please contact your fireplace dealer to purchase any replacement part. • Please make sure to provide the description and part number. • Please make sure to use a certified installer for any service related to your fireplace. 29 | P a g e...
  • Page 30: Appendix

    APPENDIX • It is recommended that a qualified service technician perform a routine inspection at the beginning of each heating season. • Disconnect power before attempting maintenance or repair of the fireplace. • Installation and maintenance must be performed by an authorized qualified installer, service agency or gas supplier.
  • Page 31: Burner Maintenance

    BURNER MAINTENANCE • The flames from the burner should be visually checked. The flame should have a blue base and yellow tops and be candle-like in appearance. • If excessive soot is found inside the firebox area, the fireplace will require adjustment. Verify the air shutter and vent restrictor setting and document any changes.
  • Page 32: Maintenance Log

    MAINTENANCE LOG FLARE FIREPLACES | MAINTENANCE LOG The following document should be used by a service technician. A copy should be kept with the technician and owner for future reference. SERVICE DATE:_____________________ UNIT INFORMATION Model Type & Size: _______________________________________ Serial Number: ____________________ Name: ____________________________ Address: ______________________________________________ Technician Name: ___________________________ Company Name: _______________________________ NPI#: _____________________________________...
  • Page 33: Warranty Policy

    WARRANTY POLICY Flare Fireplaces subjects every fireplace and component to rigorous testing to verify it is free from any defects before it leaves our warehouse. Flare Fireplaces photographs and documents the fireplace and all components’ moments before shipping them to our nationwide network of authorized dealers for installation, verifying full operation of the fireplace and all components.
  • Page 34 It is the responsibility of the installer to ensure the appliance is firing per the rating plate. • Any part that is found in our judgment to be defective shall be repaired, replaced, or refunded at Flare Fireplaces’ option. •...