The user is responsible for satisfying all local, state, and national laws, rules, codes, and regulations relating to the use of this product and its application. BERNSTEIN has made every effort to provide complete application, installation, ope- ration, and maintenance instructions. Please contact BERNSTEIN Technical Support with any questions regarding this product.
SMART T-Connector with DCD SEU-1/0-T45 Series Installation Instructions Mechanical Installation Install the SEU-1/0-T45-... to allow access for functional checks, maintenance, and service or replacement. Do not install the SEU-1/0-T45-... in such a way to allow for intentional defeat. All mounting hardware is supplied by the user. Fasteners must be of sufficient strength to guard against breakage. Use of permanent fasteners or locking hardware is recommended to prevent the loosening or displacement of the device.
SEU-1/0-T45-..A DCD compatible BERNSTEIN Safety Controller, such as the SCR P or SCR DI, provides a series connection of redundant contacts that form protective stop circuits for use in either single-channel or dual-channel control.
• Failure to properly interface the OSSD Outputs to the guarded machine could result in serious injury or death. • To ensure proper operation, the BERNSTEIN AG device output parameters and machine input parameters must be considered when interfacing the BERNSTEIN AG device OSSD outputs to machine inputs. Design the machine cont- rol circuitry so that the maximum load resistance value is not exceeded and the maximum specified OSSD Off-state voltage does not result in an On condition.
SMART T-Connector with DCD SEU-1/0-T45 Series 2.5 Wiring Figure 1. Wiring the SEU-1/0-T45-... to a panel mount Emergency Stop button SEU-1/0-T45-C with SEU-1/0-T45-AB with SFW-M12C4/AW… SFW-M12B5/AW... Pin 1 CH1a Brown CH1a Brown Pin 2 CH1b White CH1b White Pin 3 CH2a...
6. Wire the wired end of the 4-pin M12 cable (from step 1) directly to a Safety Monitoring Device, such as a DCD-enabled BERNSTEIN Safety Controller model SCR P or SCR DI. You may also wire the 4-pin M12 cable to an Daisy Chain diagnostic (DCD) module then to the Safety Monitoring device.
6. Wire the wired end of the 4-pin M12 cable (from step 1) directly to a Safety Monitoring Device, such as an DCD-enabled BERNSTEIN Safety Controller model SCR P or SCR DI. You may also wire the 4-pin M12 cable to an Daisy Chain diagnostic (DCD) module then to the Safety Monitoring device.
Page 10
SMART T-Connector with DCD SEU-1/0-T45 Series 2.5.3 Wiring Additional Power Supplies For guidance on maximum total cable length and maximum number of devices before an additional power supply may be needed, see Figure 7 on p. 10. For using DCD information to monitor the individual device voltages, see Daisy Chain diagnostic (DCD) Information on p.
SMART T-Connector with DCD SEU-1/0-T45 Series Figure 7. Maximum total cable length for a single power supply Max. Total Series Cable (m) Single Power Supply SEU-3 / 4 Number of DCD Devices The SEU-1/0-T45-... has a similar current demand to the SRF sensors.
To interpret this information, BERNSTEIN diagnostic modules are available, including the SRF-DI Diagnostic Mo- dule and the SCR DI and SCR P Safety Controller. Refer to the instruction manuals for detailed information on the diagnostic devices.
SMART T-Connector with DCD SEU-1/0-T45 Series Specifications Important: Interface the SEU-1/0-T45-... with Indication only to a SELV (Safety Extra-Low Voltage) for circuits without earth ground or a PELV (Protected Extra-Low Voltage) for circuits with earth ground power supply accor- ding to EN/IEC 60950.
SMART T-Connector with DCD SEU-1/0-T45 Series Product Support and Maintenance Maintenance and Service Do not use alcoholic cleaning agents. The SEU-1/0-T45-... is maintenance-free. For long-term and trouble-free operation, please periodically check the following points: • solid fit of all components •...
SMART T-Connector with DCD SEU-1/0-T45 Series BERNSTEIN AG Limited Warranty If the instructions (proper use, safety instructions, installation and connection by trained personnel, testing for safe operation) are violated, the manufacturer‘s liability expires. 0800000947_en 16 / 18 www.bernstein.eu Orig. 01...