1. FEATURES

● Useful for DCA measurement for automobile service.
● Accurate gearing mechanism for closing of CT.
● Data hold function. Especially useful when working in dark or hard to get areas.
● Ultra compact size.

2. SPECIFICATION

Measuring method
Display
Range
Ranging
Accuracy
Range
AC 20A (50/60Hz)
AC 200A (50/60Hz)
DC 20A
DC 200A
AC/DC CURRENT
MODEL 230+
INSTRUCTION MANUAL
Mini. Resolution
10mA
100mA
10mA
100mA
Dual integration mode
3.5 digit LCD
AC/DC 20A/200A (AC 50/60Hz)
Manual ranging
AC 50/60Hz or DC, 23℃±5℃, 80% RH max.
±1.0%rdg ±5dgt
±1.5%rdg±5dgt(0~150A )
±2.5%rdg±5dgt(150A~200A )
±1.0%rdg ±5dgt
±1.5%rdg±3dgt(0~150A)
±2.5%rdg±3dgt(150~200A)
Accuracy

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 230+ and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for MULTI MEASURING INSTRUMENTS 230+

  • Page 1 AC/DC CURRENT MINI DIGITAL CLAMP-ON TESTER MODEL 230+ INSTRUCTION MANUAL Thank you very much for selecting our digital AC/DC current clamp-on tester. This model is complex instrument and employ a very reliable mechanical/electronic design. Before you use your new instrument, read this Instruction Manual completely and familiarize yourself thoroughly with all functions.
  • Page 2 Jaw opening capability 23mmφ Over range indication “O.L” mark on LCD readout Auto power-off function Approx. 10 minutes later, after the power-on. To power-on again, at first, “off” the power-switch. Wait about 5 seconds and switching to “on” again. Maximum indication 1999 count Low battery indication "B"...
  • Page 3 4. DIMENSIONS AND PANEL FUNCTION ① ⑨ ⑧ Fig. 1 ①Current transducer(Jaw) ⑦Zero adjustment knob ②Jaw opening lever ⑧Battery cover ③Range switch ⑨AC/DC switch ④Data hold switch ⑩Power switch ⑤LCD display ⑥Wrist strap 5. METHOD OF MEASUREMENT ① Set the power switch to “ON” position. ②...
  • Page 4 The warranty period is 12 months from the date of purchase and the instrument shall be repaired at free of charge, provided that we judge the cause of defect is obviously resulted from our responsibility. MULTI MEASURING INSTRUMENTS CO.,LTD. Akihabara Murai Bldg., 7F, 1-26 Kanda Sakuma-cho, Chiyoda-ku, Tokyo,101-0025 Japan TEL : 81-3-3251-7016 FAX : 81-3-3253-4278 Home Page : http://www.multimic.com/...

Table of Contents