1. Getting started
Connect JP6 of the TC100 to the serial interface of a PC ( TXD-Pin2, RXD-Pin3, GND-Pin5 of the 9-pin Sub-D Conn.)
Run a Terminal program ( COM-setting 1200 Baud, 8 data bits, 1 stop bit, no parity, echo off )
Connect supply voltage to the TC100 ( +8...15VDC at Pin 8, GND at Pin 2 of the Mini DIN Socket )
Bridge JP8 ( PGM ) briefly
Menu appears on the screen ( "RAM Mode....")
TC100 is now in RAM program mode: Enter instructions line by line. „run" as a last line will start the program.
Shorting JP8 ( PGM ) briefly will stop the program and switch into program mode
An error message will appear with memory overflow or wrong syntax of instructions
Short programs can easily be tested that way
Caution! Program will be lost in RAM Mode after switching off the power supply!
2. Typing instructions line by line
Bridge JP8 ( PGM ) briefly
Enter instruction "burn" ( Menu "BURN Mode..." appears on the screen )
Starting from now every instruction line will be stored into the non volatile memory ( only correct syntax accepted )
Terminate by typing „end" as a last line ( total number of lines will be shown afterwards )
Program will start either by typing „run" or after every time switching the TC100 OFF and ON again
3. Uploading the „txt" file
Write the instructions line by line using any Text Editor
Depending on the desired mode use „ram&" or „burn&" as first line. In BURN Mode terminate by using instruction
„end" as a last line
Use your Terminal software to send the „txt"-file to the TC100 ( total number of lines will be shown afterwards )
Program will start either by typing „run" or after every time switching the TC100 OFF and ON again ( BURN Mode )
4. Reading the non volatile memory
Bridge JP8 ( PGM ) briefly
Enter instruction "burn" ( Menu "BURN Mode..." appears on the screen )
Enter instruction „list" ( Content of the non volatile memory will appear on the screen )
Instruction Set for Universal Controller UC100 is also valid for the Mobile Controller TC100 ( only
difference is the number of available ports, port 0, 17, 18 and 19 are possible in TC100 ) So please
use the UC100 Manual for detailed programming information until the English version of the TC100
Manual is released. All information provided on our Website
enquiry to e-mail
office@ace-tek.com
TC100 Quick Start Instruction
Universal Mobile Controller TC100
Quick Start Instruction
www.ace-tek.com
www.ace-tek.com
. Please send your
Page 1 of 3

Advertisement

loading

Summary of Contents for Ace TC100

  • Page 1 Use your Terminal software to send the „txt“-file to the TC100 ( total number of lines will be shown afterwards ) • Program will start either by typing „run“ or after every time switching the TC100 OFF and ON again ( BURN Mode ) 4. Reading the non volatile memory •...
  • Page 2 Connection Info TC100 X1 ( Jack socket 2,5mm ): Base = GND, Ring = TC100 TXD, Tip = TC100 RXD Switch S1: On / Off Switch Indicators: Lower LED ( D6 ) = Sleep / active mode, Upper LED ( D5 ) = TX-Indicator R17: Mod.-Level adjust ( Standard 0…250mVpp )
  • Page 3 TC100A / TC100B Circuit Diagram Not placed in TC100A version: IC1 and associated components TC100 Quick Start Instruction www.ace-tek.com Page 3 of 3...