SERVICING HINTS In order to prevent loose metal objects from getting in the Loosen the 4 bolts M3x18 mm until the bottom plate CD mechanism it will be necessary to see to a clean repair can be removed. station. Do not remove bolts M3x18 mm (they hold the new RAFOC unit together).
Page 10
MECHANICAL MEASUREMENTS AND ADJUSTMENTS Height seHing of the turntable After adjustment. the of the friction should checked. This is done by means of spring-pressure For th i s alignment the unit should be in the position of gauge which is connected the counterweight.
Page 11
Motor-control check (Hall) ELECTRICAL MEASUREMENTS AND ADJUSTMENTS Remove connector A09 from the motor PCS on the Laser power supply CDM. Since the light pin is very sensitive to static charges, care Connect channel A of a dual-beam oscilloscope to the should be taken that during measurements and adjust...
Page 12
1984-10-10 Motor-control check (Hall) ELECTRICAL MEASUREMENTS AND ADJUSTMENTS Laser power supply Desolder the wire from point C152 on the preamplifier printed panel on the C.D.M. Since the light pin is very sensitive to static charges, care should be taken that during measurements and adjust Connect channel A of a dual-beam oscilloscope to the emitter of transistors 6082, 6083 and channel S to the ments of the laser power supply the potentia Is of aids and...