1.0 GENERAL DESCRIPTION
This panel is designed to acquire and display depth and tension data
from a wireline logging winch unit. The panel provides the operator a
means to set and make adjustments to the data as necessary.
Depth is displayed from data provided from an encoder mounted on a
measuring device. The Quadrature Encoder pulses are passed through
to the acquisition system. The tension data is provided by a load pin and
is also passed through to the acquisition system.
AMS4A051 Hoistman's Panel Specification
36220 FM 1093
P. O. BOX 850
Simonton,Texas 77476
Phone: 281.342.6415
Fax:
281.342.4848
benchmarkwireline.com
May 2007
Page 1 of 10

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AMS4A051 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Benchmark AMS4A051

  • Page 1 Phone: 281.342.6415 Fax: 281.342.4848 benchmarkwireline.com AMS4A051 HOISTMANS DISPLAY PANEL 1.0 GENERAL DESCRIPTION This panel is designed to acquire and display depth and tension data from a wireline logging winch unit. The panel provides the operator a means to set and make adjustments to the data as necessary.
  • Page 2 Depth & tension saved in non-volatile memory at power loss Outputs for Tension and Encoder to interface to an acquisition system. RS232 Interface for additional control and data outputs. Can be set to display either English or Metric units. AMS4A051 Hoistman's Panel Specification May 2007 Page 2 of 10...
  • Page 3: Specifications

    3/8" cable – 2.031 ft. Load Cell Angle 3/16” cable – 1.44 7/32" cable – 1.38 1-4” cable - 1.23 9/32" cable – 1.08 5/16" cable - 1.00 3/8" cable – 0.85 AMS4A051 Hoistman's Panel Specification May 2007 Page 3 of 10...
  • Page 4 0 (center) position. 2.1.2 LINE SPEED DISPLAY (D2) This meter provides a digital display of line speed. 2.1.3 DEPTH DISPLAY (D3) This meter provides a digital display of depth. AMS4A051 Hoistman's Panel Specification May 2007 Page 4 of 10...
  • Page 5 The tension should be recalibrated at this time (see section 6.0). The panel should always be rebooted after new software (eprom) has been installed. AMS4A051 Hoistman's Panel Specification May 2007 Page 5 of 10...
  • Page 6: Rear Panel

    This is a 2 amp slow blow fuse. It is in series with the encoder power. It is used to protect the panel from a shorted encoder or cable. If this fuse is blown, test the encoder and encoder cable for a possible problem. AMS4A051 Hoistman's Panel Specification May 2007 Page 6 of 10...
  • Page 7 In a normal position the two pins are open. This feature can be used to interface to the winch unit control system to provide automatic hoist shutdown when an overtension condition is reached. AMS4A051 Hoistman's Panel Specification May 2007 Page 7 of 10...
  • Page 8 Run a program such as MS Windows HyperTerm using the following parameters BAUD 38,400 BITS PARITY STOP HANDSHAKE N A program is available from BenchMark to display this data (see figure below). AMS4A051 Hoistman's Panel Specification May 2007 Page 8 of 10...
  • Page 9: Menu Commands

    Following is a listing of all the available settings. OVER TENSION ALARM CABLE SIZE DELTA TENSION ALARM DIFF / INC TENSION TENSION SHUTDOWN DELTA TENSION SHUTDOWN DEPTH ADJUST (Shim) DEPTH ALARM ENCODER DIRECTION STRETCH CORRECTION AMS4A051 Hoistman's Panel Specification May 2007 Page 9 of 10...
  • Page 10: Back Panel Wiring Diagram

    36220 FM 1093 P. O. BOX 850 Simonton,Texas 77476 Phone: 281.342.6415 Fax: 281.342.4848 benchmarkwireline.com BACK PANEL WIRING DIAGRAM AMS4A051 Hoistman's Panel Specification May 2007 Page 10 of 10...