MODELS
NEKPWST2S
NEPTUNE KEYPAD TOUCH EM/HID/MF S/ALONE or WIEGAND IP65 (2x6)
PROGRAMMING
Colour Indicators refer to LED status lights on Keypad
CHANGE MASTER CODE
0
1
<NEW MASTER CODE> # <REPEAT> #
2
MASTER CODE MUST BE BETWEEN 6-8 DIGITS.
PRESS * TO EXIT PROGRAMMING
ADD PIN USERS
1
1
2
<USER NUMBER (1-2000)> #
<PIN NUMBER> #
3
ADDITIONAL USERS CAN BE ADDED BY REPEATING STEPS 2 & 3
1 1 # 9384 # 2 # 2958 # 3 # 9876 # *
The programming above added 3 users with unique pin numbers
PIN NUMBERS MUST BE BETWEEN 4-6 DIGITS
PRESS * TO EXIT PROGRAMMING
ADD CARD USERS
1
1
2
<USER NUMBER (1-2000)> #
3
<BADGE CARD>
ADDITIONAL USERS CAN BE ADDED BY REPEATING STEPS 2 & 3
1 1 # <BADGE CARD> 2 # <BADGE CARD> *
The programming above added 2 users with cards
THE ABOVE METHOD IS PREFERRED FOR CARD PROGRAMMING
SO INSTALLERS CAN NOTE WHICH USER NUMBER EACH CARD
IS ASSIGNED TO.
PRESS * TO EXIT PROGRAMMING
TSN21286-1 Rev.1 - Page 1
NEPTUNE
ENTER PROGRAMMING MODE
*
EXAMPLE
EXAMPLE
Quick Reference Guide
<MASTER CODE> # (
default 888888
ADD CARD USERS WITH MANAGER CARDS
1
2
3
THIS METHOD DOES NOT REQUIRE PROGRAMMING MODE
METHOD IS IDENTICAL FOR DELETING USERS WITH MANAGER CARD
DELETE USERS BY USER NUMBER
1
2
ALL USERS CAN BE DELETED USING THE FOLLOWING STEPS
1
2
PIN NUMBERS MUST BE BETWEEN 4-6 DIGITS
DELETE USERS BY CARD
1
2
THSI METHOD REQUIRES EXISTING CARD TO BE PRESENT
1
2
)
<BADGE MANAGER ADD CARD>
<BADGE USER CARD BEING ADDED>
<BADGE MANAGER ADD CARD>
2
<USER NUMBER (1-2000)> #
2
0000 #
PRESS * TO EXIT PROGRAMMING
2
<BADGE CARD>
PRESS * TO EXIT PROGRAMMING
SET DOOR RELAY TIME
4
0 # (50ms / 5 seconds)
DEFAULT
1 - 99 # (Another time in seconds)
PRESS * TO EXIT PROGRAMMING
13th October, 2021