Table of Contents Information about this manual ..............4 Hazard information ................... 4 Function and device overview ..............5 General system information ..............5 Mounting ....................6 Start-up ....................... 6 6.1 Pre-installation information ............... 6 6.2 Wiring information ................7 6.2.1 Connect Only UFH or Only Rads .............
1 Information about this manual This manual should be read carefully before commencing operation of your konekt wireless products. Always retain the product manuals for future use. Symbols used: Hazard indication Important information 2 Hazard information Do not open the devices except as instructed to by the installation and operation manuals.
Switching channel OUT2 (change-over contact) 4 General system information The Boiler Switch is part of the Warmup konekt Wireless System. Devices in the konekt Wireless System system can be easily paired and setup through the konekt Wireless Smart Hub using the konekt App. All functions of the konekt Wireless System are described in detail in the User Guide.
5 Mounting You can flexibly mount the boiler switch for heating systems on walls using the supplied screws and plugs. • Open the cover (B) by removing the screws, (1) at the bottom and then (2) pulling the cover down and then • Use a pen to mark the four bore holes of the switch onto the wall where you plan to mount it.
6.2 Wiring information The boiler switch must be configured in the konekt wireless App. The function of switching channel OUT1 (F) and if required, switching channel OUT2 (G) will need to be assigned using the App. Once paired to the Smart Hub you will be asked to assign this function. See section 6.3 to pair the device to the Smart Hub. 6.2.1 Connect Only UFH or Only Rads PE PE L▲...
6.2.2 Connect UFH with Rads or DHW PE PE L▲ 1▼ 2▼ 1▼ L▲ PE PE L▲ 1▼ 2▼ 1▼ L▲ 230 V AC / 50 Hz Heat Source Rads & DHW assignment UFH with DHW assignment OUT1 OUT1 Heating and cooling demand for floor Heating and cooling demand for heating actuators floor heating actuators...
6.2.4 Connect air dehumidifier PE PE L▲ 1▼ 2▼ 1▼ L▲ PE PE L▲ 1▼ 2▼ 1▼ L▲ 230 V AC / 50 Hz Dehumidifier Air dehumidifier assignment OUT1 Dehumidification for floor heating actuators...
6.3 Pairing the device to the Smart Hub The wiring centre can be paired seamlessly to the konekt Wireless Smart Hub (KW-UKHUB). To pair devices to the Smart Hub please download the konekt app. The Smart Hub must be set up via the konekt App, before any other devices can be added to your system.
1% of an hour (i.e. 36 seconds in an hour). Devices must cease transmission when they reach the 1% limit until this time restriction comes to an end. Warmup devices are designed and produced with 100% conformity to this regulation. During normal operation, the duty cycle is not usually reached.
Declaration of Conformity Warmup hereby declares that the Warmup konekt Wireless radio equipment is compliant with RED Directive 2014/53/EU and Radio Equipment Regulations 2017. Please scan the QR Code for the Declaration of Conformity.
11 Technical specifications Warmup konekt Wireless Boiler 2-Channel Switch Product Code KW-BLR2CH Operating Voltage 230 V AC / 50 Hz Current Consumption 16 A max. Standby Power Consumption < 0.2 W IP Rating IP20 Protection Class Ambient Temperature 0 to 50 °C...