Advertisement

Quick Links

San Telequip (P) Ltd.,
504/505 Deron Heights, Baner Road, Baner
Pune 411045, Mah, India
Phone : +91-20-27293455, 9764027070, 8390069393 Connecting. Converting. Leading!
email
:
info@santelequip.com
---------------------------------------------------------------------------------------------------------------------------
USER MANUAL FOR
SC15L / SC15L APS
Page 1 of 13

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SC15L and is the answer not in the manual?

Questions and answers

Summary of Contents for San Telequip SC15L

  • Page 1 San Telequip (P) Ltd., 504/505 Deron Heights, Baner Road, Baner Pune 411045, Mah, India Phone : +91-20-27293455, 9764027070, 8390069393 Connecting. Converting. Leading! email info@santelequip.com --------------------------------------------------------------------------------------------------------------------------- USER MANUAL FOR SC15L / SC15L APS Page 1 of 13...
  • Page 2: Table Of Contents

    San Telequip (P) Ltd., 504/505 Deron Heights, Baner Road, Baner Pune 411045, Mah, India Phone : +91-20-27293455, 9764027070, 8390069393 Connecting. Converting. Leading! email info@santelequip.com --------------------------------------------------------------------------------------------------------------------------- Table of Contents 1 Introduction 2 Features 3 Operation 4 Connection Details 5 Configuration 5.1 Docklight Settings 5.2 Device Configuration...
  • Page 3: Introduction

    SC15L/SC15LAPS device will transmit serial data to other connected device transparently SC15L APS will broadcast the serial data received on its serial port to all connected SC15L devices in the network and all SC15L devices will transmit their serial data to access point (SC15LAPS).
  • Page 4 --------------------------------------------------------------------------------------------------------------------------------------- Packet mode In this mode SC15L device will send data on serial port transparently. Data received at access point will contain the unique device ID of transmitter device (SC15L). One SC15LAPS will receive data from SC15L with their specific Device ID which will help user to bifurcate data and arrange it accordingly.
  • Page 5: Connection Details

    San Telequip (P) Ltd., 504, 505 Deron Heights, Baner Road Pune 411 045, India Phone: +91-20-27293455, 9764027070, 8390069393 Connecting. Converting. Leading! email : info@santelequip.com --------------------------------------------------------------------------------------------------------------------------------------- • Function Code 01: To read the current status of Digital Output with respect to their device ID •...
  • Page 6: Configuration

    +Vin -Vin Earth 5. Configuration Connect RS485/RS232 connector of SC15L/SC15L APS to the PC. 5.1 Docklight Setting Open Project setting in your Docklight then change the COM PORT name to COM PORT of the connected device. Select Baud Rate, Parity and Stop Bits as per previously stored data while configuration and keep Data Bits 8(fixed).
  • Page 7: Device Configuration

    • LED will Glow for 30 Sec. within this 30 Sec enter “UUU” in docklight window through keyboard. • Start message will display on screen along with main menu. SC15L **************************************************<CR> * Product description: SC15L *<CR> * Firmware version : 1.00 *<CR>...
  • Page 8 Connecting. Converting. Leading! email : info@santelequip.com --------------------------------------------------------------------------------------------------------------------------------------- 5.2.1 Enter ‘1’ to select Mode of work • If your device is SC15L APS then below message will display after your selection : Current Mode is: Not Set<CR> Select Work Mode <CR>...
  • Page 9 Enter your desired device ID. Note: • If your device is SC15L/SC15L241 then keep device ID within range of 1 to 99. • If your Device is SC15L APS then keep your device ID above 100. • Based on your requirement select Device Address then enter ‘B’ to go back to system menu.
  • Page 10 San Telequip (P) Ltd., 504, 505 Deron Heights, Baner Road Pune 411 045, India Phone: +91-20-27293455, 9764027070, 8390069393 Connecting. Converting. Leading! email : info@santelequip.com --------------------------------------------------------------------------------------------------------------------------------------- Note: • All connected devices must have same data rate to communicate with each other.
  • Page 11: Led Indications

    Device is waiting to enter configuration mode Device is Transmitting Data Device is Receiving Data 7. MEMORY MAP in SC15L APS 1. DI Data: a) Function Code – 02: INPUT STATUS 2. AI Data: a) Function Code – 03: HOLDING RESISTER 3. DO Data: a) To read DO data use Function Code –...
  • Page 12 For this configuration to read DI status of device enter configuration as follow • AI data will be stored in location: [(SC15L Device ID-1)*30 + 8] • Device ID = 6, therefore: [(6-1) *30 + 8]= [5*30 + 8] = 158.
  • Page 13 --------------------------------------------------------------------------------------------------------------------------------------- For this configuration to read AI status of device enter configuration as follow • DI data will stored in location : (SC15L Device ID-1)*30 • Device ID = 6, therefore: (6-1)*30 = 5*30 = 150. For this configuration to read DI status of device enter configuration as follow...