Operating Manual V1.0 - 05/2021 MAN.26.1 Chapters page 3 1. General Warnings and Safety Specifications La Marzocco S.r.l. page 8 2. Definition of Available Models Via La Torre 14/H Località La Torre page 10 3. Installation 50038 Scarperia e San Piero...
1. General Warnings and Safety Specifications more than 8 years of age) WARNING CAUTION This appliance is for professional As already mentioned in with reduced physical, use only and should be installed the preceding notes, the sensory mental in locations where its use and manufacturer shall not be held capabilities, or lack of maintenance is restriced to...
Page 4
2) This operating manual 7) The equipment must be Check machine’s is an integral and essential integrity after having carefully installed to comply with the part of the product and removed the packaging. applicable federal, state or must be supplied to users. Note: In case of doubt, do not go on local electrical and plumbing Users are asked to read...
Page 5
national, and international exclusively of the kind which fundamental rules electrical codes and safety conforms to local, national, observed. In particular: regulations, and particularly and international electrical • do not touch the device grounding unit. codes and safety regulations, with wet or humid hands Make sure grounding has being careful not to exceed and feet;...
Page 6
14) Before carrying out any 18) Do not obstruct air intake a qualified and authorized maintenance and/or cleaning professional to perform any and exhaust grilles and, in operations, turn the main repair. Any repairs must particular, do not cover the switch, which is located on performed exclusively...
Page 7
Maximum room temperature: Features 32°C/89°F. machine been temporarily housed in settings with a room wally milk temperature of less 0°C/32°F, A [mm] the machine must be placed B [mm] in a warmer environment in C [mm] order to gradually defrost the WEIGHT [kg] hydraulic system prior to use.
Software Programming your appliance. WARNING Do not soil the lower area of the sensor when handling the wand. Failure to observe this warning may affect the operation of the appliance. Fig. 1 - Model wally...
Page 9
To operate the machine, it must burns as a result of a contact. be connected to a steam source using the To ensure proper functioning over time WALLY MILK WA000000 specific connection tube. Do not use tubes and always provide high-quality beverages,...
- U.S.A. and CANDA only - Do not WARNING For the best result we connect to a circuit operating WARNING recommend using the supplied at more than 150V to ground on This appliance should not be Wally pitchers. each leg. installed in kitchens.
Page 11
Note: WARNING WARNING • The drinking water mains valve and In order to prevent cracks or Ensure the correct connection the circuit breakers for the electrical leakage: do not store or install of the supply tube. Improper system need to be located in the most convenient position for the operator to the appliance in places where installation can cause the...
Page 12
1) Steam connection 3) Waste water drain connection Connect the supply pipe of the steam The connection of the drain of the machine source to the machine, ensuring the must be realized thanks to the plastic tube mechanical seal of the terminal fittings included in the supply.
For cleaning motion of the platform to prevent operations, please follow the machine damage and improper instructions listed below very milk frothing. carefully. WARNING WARNING This appliance is designed only 2) Pitcher Maintain the temperature sensor for preparing hot drinks.
Page 14
Be careful not to allow liquid to overflow in Programming order to avoid severe burns. Encoder Once the milk is frothed and the wand has returned to the upper point, it is possible 4) Steaming milk to drain. Press and hold the activation Press the activation button and wait for button for the desired time for wand drain.
5. Maintenance and Periodic Cleaning Operations WARNING 3) Cleaning the steam nozzles WARNING Steam nozzles must cleaned The appliance must not be dipped If the above-mentioned instructions immediately after use with a damp cloth in, nor splashed with, water in order are not adhered to the manufacturer and by producing a short burst of steam so as to prevent the formation of deposits...
6. De-commissioning and Demolition 1) De-commissioning and demolition At this point, the appliance may be Recycling notice: Warning for the protection of the removed from the bar, being very careful environment. Start by setting the main switch to the “0” not to drop it or squash your fingers.
Page 20
“Technical” Programming Recipe Recipe Steaming Steaming Manual Manual Steaming Steaming Manage Manage Recipes Recipes Machine Machine Configuration Configuration page 22 page 28 Press and hold the Encoder Knob for 5 seconds. Language Temperature Units Full Access Pitcher Size ENGLISH CELSIUS Mode AUTODETECT ENABLED...
Page 22
Programming Display Home 0°C Recipe Steaming Manual Steaming Manage Recipes Machine Configuration You can turn on/off the machine by Graphic programming display with Machine configuration (access the pressing and holding the Encoder knob. Encoder programming menu Steam temperature Encoder knob: Rotating to the right increases the value.
Page 23
Start Up Procedures Description Turning the Appliance On Programming Mode The following is the procedure for turning • Proceed checking for water connection on the power to the appliance. to the appliance. Home 0°C • Please follow the procedures carefully to Recipe Steaming avoid any damage to the appliance.
Page 24
Shut Down Procedures Description Turning the Appliance Off Programming Mode The following is the procedure for turning off power to the appliance. • Please follow the procedures carefully to avoid any damage to the appliance. Display Operating Procedure Turn the Main Switch to the 0 position. This is the OFF setting used in the normal operating conditions.
Page 25
Recipe Steaming Description Programming Mode Recipe Steaming • This parameter allows the operator to • This parameter allows the operator to view and choose all saved recipes. choose the preferred one from the saved Home 0°C recipes and to start it by pressing the Recipe Steaming start button.
Page 26
Manual Steaming Description Programming Mode Manual Steaming • This parameter allows the operator to • This parameter allows the operator dispense manually. to choose from various options, such Home 0°C as Stretching (foam amount of the Recipe Steaming beverage) and temperature. Manual Steaming Manage...
Page 27
Manage Recipes Description Programming Mode Manage Recipes • This parameter allows the operator to • This parameter allows the operator manage the recipes. to choose from various options, such Home 0°C as moving, deleting, and editing the Recipe Steaming recipes. Manual Steaming Manage...
Page 28
Accessing Programming Mode Description Programming Mode Programming Mode • To change the values of any parameter operator can change to affect the quality the operator must first enter into the of the steam. Home 0°C programming mode. No password is required for access. Recipe Steaming •...
Page 29
Accessing Programming Mode Description Programming Mode Programming Mode Marzocco reccomends that no changes are made at this level. The Technician Home 0°C Password is required for access. Recipe Steaming Manual Steaming Manage Recipes Machine Configuration Display Operating Procedure Enter Password This is the “Technical”...
Page 30
“Barista” Programming Description Programming Mode Language • This parameter allows the operator to change the language of the display. Language ENGLISH Display Operating Procedure Recipe Steaming Manual Press the Encoder Knob to access the “Barista” programming menu. Steaming Manage Recipes Machine Configuration Language...
Page 31
“Barista” Programming Description Temperature Measurement Units Programming Mode • This parameter allows the operator to change the temperature display from degrees Celsius to degrees Fahrenheit Temperature Units CELSIUS and vice versa. Display Operating Procedure Recipe Steaming Manual Press the Encoder Knob to access the “Barista” programming menu. Steaming Manage Recipes...
Page 32
“Barista” Programming Description Programming Mode Pitcher Size • This parameter allows the operator to adjust the settings of the pitcher. Pitcher Size AUTODETECT Display Operating Procedure Recipe Steaming Manual Press the Encoder Knob to access the “Barista” programming menu. Steaming Manage Recipes Machine...
Page 33
“Barista” Programming Description Programming Mode Exit Menu • This parameter allows the operator to exit the programming and return to the normal use of the appliance. Exit Menu Display Operating Procedure Recipe Steaming Manual Press the Encoder Knob to access the “Barista” programming menu. Steaming Manage Recipes...
Page 34
“Technical” Programming Description Programming Mode Language • This parameter allows the technician to change the language of the display. Language ENGLISH Display Operating Procedure Recipe Steaming After entering the password and accessing the “Technician” programming menu, rotate the Encoder Knob until Manual Steaming the following is displayed.
Page 35
“Technical” Programming Description Temperature Measurement Units Programming Mode • This parameter allows the technician to change the temperature display from degrees Celsius to degrees Fahrenheit Temperature Units CELSIUS and vice versa. Display Operating Procedure Recipe Steaming After entering the password and accessing the “Technician” programming menu, rotate the Encoder Knob until Manual Steaming the following is displayed.
“Technical” Programming Description Programming Mode Full Access • This parameter allows the technician to enable or disable recipe management and editing. Full Access Mode ENABLED Display Operating Procedure Recipe Steaming After entering the password and accessing the “Technician” programming menu, rotate the Encoder Knob until Manual Steaming the following is displayed.
Page 37
“Technical” Programming Description Programming Mode Pitcher Size • This parameter allows the technician to adjust the settings of the pitcher. Pitcher Size AUTODETECT Display Operating Procedure Recipe Steaming After entering the password and accessing the “Technician” programming menu, rotate the Encoder Knob until Manual Steaming the following is displayed.
Page 38
“Technical” Programming Description Programming Mode Manual Purge • This parameter allows the technician to set the time for the drain of the steam wand. Manual Purge Max Duration 15,0 s Display Operating Procedure Recipe Steaming After entering the password and accessing the “Technician” programming menu, rotate the Encoder Knob until Manual Steaming the following is displayed.
Page 39
“Technical” Programming Description Programming Mode Low Purge • This parameter allows the technician to choose whether to drain with the steam wand in low or high position. Low Purge ENABLED Display Operating Procedure Recipe Steaming After entering the password and accessing the “Technician” programming menu, rotate the Encoder Knob until Manual Steaming the following is displayed.
“Technical” Programming Description Programming Mode Reset Recipes • This parameter allows the technician to delete all the recipes saved. Reset Recipes Display Operating Procedure Recipe Steaming After entering the password and accessing the “Technician” programming menu, rotate the Encoder Knob until Manual Steaming the following is displayed.
“Technical” Programming Description Programming Mode Electronics Board • This parameter allows the technician to display the hardware and firmware version for all the electronic boards Electronics Settings installed on the appliance. Display Operating Procedure Recipe Steaming After entering the password and accessing the “Technician” programming menu, rotate the Encoder Knob until Manual Steaming the following is displayed.
Page 42
“Technical” Programming Description Programming Mode Electronics Board • This parameter allows the technician to display the hardware and firmware version for all the electronic boards Electronics Settings installed on the appliance. Display Operating Procedure Force FW Upgrade On Next Startup ENABLED Press the Encoder Knob to access the menu, rotate the Encoder Knob to choose between ENABLED and DISABLED, press the Encoder Knob to confirm the option.
Page 43
“Technical” Programming Description Programming Mode Reset • This parameter allows the technician to • It is possible to reset the settings you reset all the values returning to initial made in the “Barista” programming or factory settings. the settings you made in the “Technical” Reset Settings programming.
Page 44
“Technical” Programming Description Programming Mode Reset • This parameter allows the technician to • It is possible to reset the settings you reset all the values returning to initial made in the “Barista” programming or factory settings. the settings you made in the “Technical” Reset Settings programming.
“Technical” Programming Description Programming Mode Diagnostic Test • This parameter allows the technician to verify the proper operation of the appliance. Diagnostic Test Settings Display Operating Procedure Recipe Steaming After entering the password and accessing the “Technician” programming menu, rotate the Encoder Knob until Manual Steaming the following is displayed.
Page 46
“Technical” Programming Description Programming Mode Diagnostic Test • This parameter allows the technician to verify the proper operation of the appliance. Diagnostic Test Settings Display Operating Procedure Run Technician Hydraulic Test Press the Encoder Knob to run the Hydraulic Test. Platform Calibration Press the Encoder Knob to run the Platform Calibration.
Page 47
“Technical” Programming Description Programming Mode Diagnostic Test • This parameter allows the technician to verify the proper operation of the appliance. Diagnostic Test Settings Display Operating Procedure Platform Offset 1,0 steps Press the Encoder Knob to enter the menu, rotate the Encoder Knob to set the desired value, press the Encoder Knob to confirm the value.
Page 48
“Technical” Programming Description Programming Mode Diagnostic Test • This parameter allows the technician to verify the proper operation of the appliance. Diagnostic Test Settings Display Operating Procedure Set Custom Emissivity Press the Encoder Knob to run the Set Custom Emissivity. Temperature Sensor Test Press the Encoder Knob to run the Temperature Sensor Test.
Page 49
“Technical” Programming Description Programming Mode Diagnostic Test • This parameter allows the technician to verify the proper operation of the appliance. Diagnostic Test Settings Display Operating Procedure Diagnostic Test Exit Press the Encoder Knob to quit the submenu.
Page 50
“Technical” Programming Description Programming Mode Dose Counter • This parameter allows the technician • This parameter displays different values: to review the total doses dispensed for • Total steaming doses; each button. • Total purges doses; Total Doses Steaming: • Total small doses;...
Page 51
“Technical” Programming Description Programming Mode Update Firmware • This parameter allows the technician to update the control unit of the appliance via a USB Pendrive. Update Firmware Display Operating Procedure Recipe Steaming After entering the password and accessing the “Technician” programming menu, rotate the Encoder Knob until Manual Steaming the following is displayed.
Page 52
“Technical” Programming Description Programming Mode Update Firmware • This parameter allows the technician to update the control unit of the appliance via a USB Pendrive. Update Firmware Display Operating Procedure Insert USB Key and Press Enter Insert the USB Pendrive into the USB port and press the Encoder Knob. When the update is over, the appliance restarts.
Page 53
“Technical” Programming Description Programming Mode Exit Menu • This parameter allows the technician to exit the “Technical” programming and return to the normal use of the Exit Menu appliance. Display Operating Procedure Exit Menu Press the Encoder Knob to exit the “Technician” programming mode and return to the normal use of the appliance.