Product Name
Model
Photo
Intended Use
Reference standard
Reference regulation Regulation (EU) 2016/425 of the European Parliament and of the Council
Component
Material
Specs
Checks prior to use
Usage Method
Duration
Respiratory Face Mask
M-9520A
As a respirator, it is intended to help reduce wearer exposure to certain airborne
particles (solid and liquid aerosols) which are hazardous to health.
EN 149:2001+A1:2009
Face Mask Body、Nose Clip、Earloop、Sponge pad
Polypropylene non-woven fabrics
Maximum penetration of test aerosol : < 6%
Total inward leakage(TIL): < 8%
Inhalation resistance : < 70 Pa at 30L/min, < 240 Pa at 95L/min
Exhalation resistance : < 300 Pa at 160L/min
Before use, check the date of storage of a mask and the technical condition whether a
mask has no wisible mechanical damage, is not contaminated or incomplete. A damaged
mask and the one whose storage data has been exceeded cannot be used
1. Pull an extend the mask inner side to the face with two hands,ensure the nose clip
is upward.
2. Hold the mask on the face and pull the earloop to the ears.
3.
Press the nose clip to fit the shape of the nose.
4.
Check and press the mask fit to the face to minimize leakage. If you cannot achieve
a proper seal, DO NOT enter the contaminated area. See your supervisor.
Less than 8 hours is recommended.
Classification
FFP2 NR