Download Print this page

DeLonghi 40EDDH30 Use And Maintenance Manual page 10

Use and maintenance manual

Advertisement

GB
12-12-2003
16:15
Frequently, a problem is minor and a service call may not be necessary. Use this troubleshoo-
ting guide to identify possible problems you may be experiencing.
Unit does not operate
Dehumidifying capacity (moi-
sture removal) low
Relative Humidity setting not
reached after long period of
operation
Frost appears on coils
Pagina 11
Tr o u b l e s h o o t i n g t i p s
PROBLEM
• Check power cord connection.
• Check electrical outlet for blown fuse.
• Check if water tank is full (empty).
• Check water tank is properly installed.
• Check if the unit is not turned on.
• Air filter is dirty and /or blocked.
• Ambient room temperature too low.
• Poor airflow circulation/obstruction
• The control may not be set high enou-
• Check all doors and windows are clo-
• Area/room is too large for the capa-
• Room temperature is too low
POSSIBLE CAUSE
gh
sed
city of the dehumidifier
11

Advertisement

loading