Operating Manual Contents Before You Begin ............................3 Safety Considerations ...........................3 Warning Symbols Used in Accordance With IEC 417 ...................3 Introduction ..............................5 Unpacking/Packing the Genoseal ..........................5 Principle of Operation ...........................5 Installation ...............................6 Intended Use ..................................6 Inventory ................................6 Operating Environment ..........................6 Connecting the Voltage Supply ..........................6 Operation Procedure ............................7 Optimization ..............................8 Temperature and Time Setting ..........................8...
Page 4
These components are marked with the hot surface symbol. Due care should be taken to avoid personal injury. Spex accepts no responsibility for the misuse of this equipment. Please ensure that heater block is at ambient temperature before cleaning and a senior operator carries out the cleaning.
Operating Manual Introduction The Genoseal heat sealer has been designed to seal most types of microplates. Our product utilizes various heat seal films and foils to give either permanent or peelable seals for all common microplate material types (polypropylene, polystyrene, polyethylene). Seal times and seal temperatures are fully adjustable on the product via the control screen.
Caution: Use appropriate lifting and carrying equipment available in the facility during unit movement from one place to another. Always use any necessary PPE during unit movement. Inventory Note: All of the items listed below are available as spare components from Spex. DESCRIPTION PART NUMBER...
Operating Manual Operation Procedure Plate Locators and Adapters Shuttle Plate Locator Plate Plate locators are used specifically on skirted plates, it allows for the plate skirt to sit around the corresponding locator and support the underneath of the plate. To ensure the correct plate locator is used, check the difference in the bottom of the well distance to the plate skirt base, if there is a difference, the center of...
2 to 5 Sealing PCR Plates - No Skirt, Half Skirt An adapter will be required to seal plates which have well bottoms protruding past the plate skirt as well as plates with no skirt. This is available from Spex. 1300-87075-1A...
Plug in the system to turn the power on. Once the system is turned on, the Spex logo is displayed. The home screen appears as shown to the left. If the system is in ECO mode, it will prompt you to wake it.
Page 10
Operating Manual This screen will allow you to select the settings that control the sealing time, temperature, ECO time and scan a copy of the user manual through the QR code displayed. After clicking settings, you will be shown this screen, simply click the o To adjust the set temperature of the heater block and control the temperature that the Genoseal seals at, click...
12.13 in x 8.1 in x 15.3 in (308 mm x 205 mm x 389 mm) Unit Weight 19.8 lb (9 kg) Troubleshooting If the problem with the Genoseal unit persists after the below actions have been carried out, contact Spex for further investigation. PROBLEM ACTION...
Operating Manual Service and Repairs For all requirements for service and repairs please contact: Spex at +1.732.549.7144. Note: For any spare components, please refer to the inventory list and contact Spex for pricing information. Regulatory Information CE Declaration of Conformity As detailed under the European Machinery Directive 89/392/EEC (amended by 91/368/EEC) and under the UK legislation.