SmartDHOME MyOT 01335-2080-00 User Manual

SmartDHOME MyOT 01335-2080-00 User Manual

Interface/actuator for opentherm boilers

Advertisement

Quick Links

MyOT interface/actuator for OpenTherm Boilers
User manual
Thank you for choosing the interface / actuator for OpenTherm boilers, the latest generation
device that allows you to monitor the performance of the OpenTherm boilers on which it is
installed. Z-Wave certified, it is compatible with any gateway that communicates through this
protocol such as MyVirtuoso Home.
www.myvirtuosohome.com
www.smartdhome.com
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MyOT 01335-2080-00 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for SmartDHOME MyOT 01335-2080-00

  • Page 1 Thank you for choosing the interface / actuator for OpenTherm boilers, the latest generation device that allows you to monitor the performance of the OpenTherm boilers on which it is installed. Z-Wave certified, it is compatible with any gateway that communicates through this protocol such as MyVirtuoso Home. www.myvirtuosohome.com www.smartdhome.com...
  • Page 2: General Safety Rules

    4. Do not use the device in gas saturated environments. 5. Do not place the device near heat sources. 6. Use only the original EcoDHOME accessories supplied by SmartDHOME. 7. Do not place the connection and / or power cables under heavy objects, avoid paths near sharp or abrasive objects, prevent people from walking on them.
  • Page 3: Intended Use

    Disclaimer SmartDHOME Srl cannot guarantee that the information regarding the technical characteristics of the devices in this document are correct. The product and its accessories are subject to constant checks aimed at improving them through careful research and development analyses.
  • Page 4 Daikin, Ferroli, Fondital, Italtherm, La Bongio, LG, Savio, Sime, Sylber, Panasonic, Ravenheat, Riello, Unicalm, Immergas, Innovita and Arca Caldaie. To stay up to date, visit the product page on the site: https://www.smartdhome.com/en/projects/iot-devices/iot-connected-boilers.html The parts of the MyOT interface / actuator for OpenTherm boilers GREEN...
  • Page 5: Warning Leds

    MyOT interface/actuator for OpenTherm Boilers User manual Device Connections To operate the device, you have to understand the utility of the green connector (see Tab. SIGFOX/ZWAV Figure 2: Aerial and green connector. E AERIAL Tab. 1: green connector SIGFOX/ZWAVE OpenTherm OpenTherm OpenTherm OpenTherm...
  • Page 6 Wi-Fi Error. Possible causes: • No connection to the local network. • No connection to the SmartDHOME server (no Internet connection, server temporarily unavailable, etc). Wi-Fi Configuration WARNING! The device has several communication modes that cannot be configured at the same time.
  • Page 7 MyOT interface/actuator for OpenTherm Boilers User manual Open the IoB application and press the Set Remote Server/Wi- Fi button in the Home (see image). After that, click on CONTINUE on the pop-up that will appear. Swipe on the Wi-Fi section (see image) and press on the symbol to see the complete list of detected Wi-Fi.
  • Page 8: Z-Wave Configuration

    MyOT interface/actuator for OpenTherm Boilers User manual 1. Switch on the device. 2. Press the FUNCTIONS button for 3 seconds. 3. Release the button and verify that the device is in configuration mode. The LEDs will flash alternately (red and green). 4.
  • Page 9 MyOT interface/actuator for OpenTherm Boilers User manual These are described in the following sections. COMMAND_CLASS_BASIC This command class can be used to switch the boiler on/off (or to know the current status). However, the auto-report of this CC was not implemented for performance reason. Therefore, to perform the same operation is recommended to use the COMMAND_CLASS_SWITCH_BINARY.
  • Page 10 MyOT interface/actuator for OpenTherm Boilers User manual Sensor type (hex) Sensor type (dec) Measure 0x01 Exhaust fumes temperature 0x09 Heating circuit pressure 0x17 Return water temperature 0x38 DHW Flow 0x3D Boiler heating modulation 0x3E Boiler water temperature 0x3F DHW Temperature COMMAND_CLASS_CONFIGURATION This command class maps a series of parameters that are obtained from the boiler.
  • Page 11: Warranty And Customer Support

    If you encounter technical problems or malfunctions, visit the site: http://helpdesk.smartdhome.com/users/register.aspx After a short registration you can open a ticket online, also attaching images. One of our technicians will answer you as soon as possible. SmartDHOME Srl V.le Longarone 35, 20080 Zibido San Giacomo (MI) info@smartdhome.com Rev. 06/2021...