Page 1
500 Watt Puresine Solar Power Generator User Manual WARNING: Read carefully and understand all assembly and operation instructions before operating. Failure to follow the safety rules and other basic safety precautions may result in serious personal injury. Item # 40500 SAVE THESE INSTRUCTIONS...
Important Safety Information Thank you for choosing a Nature Power Product. Save the receipt and these instructions. It is important that you read the entire manual to become familiar with this product before you begin using it. This product is designed for certain applications only. the distributor cannot be responsible for issues arising from modification.
Page 3
Cautions This product has a built-in high-voltage power supply and battery. keep away from children. For long-term storage (more than one month), please charge the power generator to about 70%. Do not charge near fire or overheating. Use or place. Do not use in damp environment, do not knock or hit the product Please charge with the original adapter or according to the adapter in accordance with the electrical parameters specified by the manufacturer.
Contains a wide range of application areas, such as rescue and disaster relief, emergency rescue, first aid, outdoor exploration, outdoor construction, outdoor shooting, outdoor live broadcast, outdoor stalls, tourism, camping, solar power and other fields. Parts List Reference 40500 power generator AC Charger 10W Semiflex solar panel Manual...
Product Function Item # 40500 HANDLE LCD DISPLAY AC POWER SWITCH DC POWER SWITCH 2X 110V AC OUTPUT CHARGING / DC POWER INDICATOR USB / USB-C OUTPUT SOLAR IN,120W MAX AC IN / DC5525 OUT CAR CHARGE IN / 12V,10A OUT...
LCD Display Battery Level AC Output Power Solar Charging Current Charging The power generator has a charging protection function and is used in accordance with normal charging operations. After the power generator is fully charged, it will automatically stop charging. If you need to use it while charging, the output power should less than 100W, and it will be fully charged according to the internal battery capacity.
Page 7
3. Solar Charging 3.1 Solar panel power less than 120W 1. The included 10W Semiflex solar panels coming with DC socket connector can directly connect to the solar port for charging. the other solar panels with DC socket connector and less than 120W can be the same.
Page 8
Output This power generator is designed with 3 areas function outputs, namely AC area, DC area, and USB area. 1, AC Output Turn on the AC power switch and the LCD will light up. The buzzer will beep for about 2 seconds. The fan will run 3 seconds at the same time and AC output function will be turned on.
Specification Model 40500 Battery 21700 Lithium ion Battery Power 500W Rate / 1000W Peak Capacity 550WH 12.6V Max Battery Voltage 1000 Times Lifecycle Over current / over Charge / over discharge / Short Circuit Protection Protection AC Charger Input Voltage...
Page 10
What happen if the AC output overloads? A beep will sound and then the power generator will be turned off. After removing some electrical appliances, the power generator can be turned on again for normal use. Does the power generator need to be turned on for charging? Please Switch the DC POWER to “ON”...
Trouble Shooting Power generator will not turn on, no output Remove the product load, charge for 5-10 minutes and reboot. Please ensure the power generator is in normal temperature range. Power generator will turn on, but has no output Low battery, charge in time. Check the rated power of electrical appliances, higher than the generator peck power will cause protection, remove the load, and restart.
Limited Warranty Nature Power warrants our products to the original purchaser that this product is free from defects in materials and workmanship for the period of 1 year from date of purchase. In the case of product defect, contact Nature Power customer service to receive trouble shooting. If defective part or unit should be returned, a Return Authorization Number must be issued by Nature Power and the defective part or unit should be returned to the authorized location at the purchasers’...