ModbusLink-M/
ModbusLink-S
O
&
PERATIONS
M
M
AINTENANCE
ANUAL
Part No. 8800-1197
Revision – 1.0
April 1, 2013

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ModbusLink-M and is the answer not in the manual?

Questions and answers

Summary of Contents for Sutron ModbusLink-M

  • Page 1 ModbusLink-M/ ModbusLink-S & PERATIONS AINTENANCE ANUAL Part No. 8800-1197 Revision – 1.0 April 1, 2013...
  • Page 3: Table Of Contents

    SUTRON MANUFACTURED EQUIPMENT ............... 16 NON-SUTRON MANUFACTURED EQUIPMENT ............. 16 REPAIR AND RETURN POLICY ..................16 EXTENDED WARRANTY AND ON-SITE MAINTENANCE ..........16 Bringing the Benefits of Real-Time Data Collection to the World Sutron Corporation, 22400 Davis Drive, Sterling, Virginia 20164...
  • Page 4: Introduction

    Master/logger/data recorder and at least one slave (ModbusLink-S). Each Slave unit can be connected to one Modbus sensor via either a RS232 or RS485 port. If the ModbusLink-M is unable to reach a Modbus sensor directly, it will try to discover a route to the destination via intermediate ModbusLink-S modules.
  • Page 5: Unpacking

    Unpacking Unpacking Remove the ModbusLink-M and ModbusLink-S units from the shipping container and visually inspect the unit for signs of damage during shipment. Report any such damage to the factory immediately to ensure a prompt response and resolution. Retain one shipping container in the event a factory return is necessary.
  • Page 6: Hardware Description

    Hardware Description Connectors The ModbusLink-M/S modules support the Modbus protocol (RTU mode) over RS-232(default) or RS-485, selectable via a simple command. The external IP6 rated DB9 connector should be used for communication with Modbus loggers/Sensors using RS-232. For interfacing with a modbus logger/sensor over RS-485, a 5- terminal connector is provided.
  • Page 7: Terminal Block

    Power Ground Battery Connections The ModbusLink-M/S has an internal battery to power the unit; however, external power (8-16v dc) can be applied to J3. If external power is applied, the internal battery is automatically cut off and the module runs off the external supply.
  • Page 8: Setup And Operation

    ModbusLink-S module with the same address in the network. If the destination node is not within radio range of the ModbusLink-M module, it will try to discover a route via intermediate ModbusLink-S modules. If multiple routes are possible to the destination, the most efficient route will be selected.
  • Page 9 If an intermediate node cannot deliver a message to the next hop, it informs the sender, which starts a new route discovery. Bringing the Benefits of Real-Time Data Collection to the World Sutron Corporation, 22400 Davis Drive, Sterling, Virginia 20164...
  • Page 10: Setup

    ModbusLink-S module must match that of the modbus Sensor connected to it. The ModbusLink-S can be configured to operate in Auto address mode or it can also be assigned a static address. The ModbusLink-M module does not need any address configuration.
  • Page 11: Configuring Modbuslink

    = slave if device is configured as (this command Modbus device as a Modbus master requires the module to ModbusLink-S be power cycled to take effect) Bringing the Benefits of Real-Time Data Collection to the World Sutron Corporation, 22400 Davis Drive, Sterling, Virginia 20164...
  • Page 12: Optional Mounting Bracket Kit (2911-1395)

    >ERROR : Destination not found of time the LED on remote node. Unable to locate remote node If time = 0 , the Led will blink forever Factory Defaults =!Sutron! Restores all settings to factory defaults Optional Mounting Bracket Kit (2911-1395)
  • Page 13 The optional mounting bracket kit provides an easy way to mount the ModbusLink modules to a 1.5" standard pipe. The kit includes the mounting plates, alignment bracket and u-bolts/hose clamps and screws to Bringing the Benefits of Real-Time Data Collection to the World Sutron Corporation, 22400 Davis Drive, Sterling, Virginia 20164...
  • Page 14: Quick Start Guide

    After powering on the ModbusLink-M and ModbusLink-S modules, wait for about 2 minutes for the slaves to finish scanning for a Modbus Sensor(automatic address mode only). Issue command “NwScan” and wait for a few minutes for the scan to complete.
  • Page 15: Troubleshooting And Maintenance

    Typical maintenance for the unit consists of checking the wiring to make sure it is not corroded or frayed and examining the unit to ensure that there is no physical damage. Bringing the Benefits of Real-Time Data Collection to the World Sutron Corporation, 22400 Davis Drive, Sterling, Virginia 20164...
  • Page 16: Specifications

    2.4 GHz license free band Range 300m LOS Network type Ad-hoc homogenous mesh Power consumption 450µA @ 3.6v average (~3mA for ModbusLink-M if using modbus over RS485) Battery Life ~ 5 years (internal battery included) RF power 3dBm (max) Antenna...
  • Page 17 Of course not all problems can be fixed over the phone. Sometimes a customer needs an on-site technician to identify site related problems or troubleshoot a network. Sutron can provide these services at a reasonable cost. Call for details. If you would like to learn more about Sutron products email sales@sutron.com...
  • Page 18: Appendix E- Commercial Warranty

    The above Warranty applies only to products manufactured by Sutron. Equipment provided, but not manufactured by Sutron, is warranted and will be repaired to the extent of and according to the current terms and conditions of the respective equipment manufacturers.

This manual is also suitable for: