ESD electronic VME-PMC-CADDY Hardware Manual

Vme-carrier board for pmc-modules

Advertisement

Quick Links

VME-PMC-CADDY
VME-Carrier Board for PMC-Modules
Hardware Manual
to Product
V.1911.01,
V.1911.10,
V.1911.11
VME-PMC-CADDY
Hardware Manual • Doc. No.: V.1911.21 / Rev. 1.9
Page 1 of 33
esd electronic system design gmbh
Vahrenwalder Str. 207 • 30165 Hannover • Germany
http://www.esd.eu
Phone: +49 (0) 511 3 72 98-0 • Fax: +49 (0) 511 3 72 98-68

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the VME-PMC-CADDY and is the answer not in the manual?

Questions and answers

Summary of Contents for ESD electronic VME-PMC-CADDY

  • Page 1 VME-PMC-CADDY Hardware Manual • Doc. No.: V.1911.21 / Rev. 1.9 Page 1 of 33 esd electronic system design gmbh Vahrenwalder Str. 207 • 30165 Hannover • Germany http://www.esd.eu Phone: +49 (0) 511 3 72 98-0 • Fax: +49 (0) 511 3 72 98-68...
  • Page 2 This manual contains important information and instructions on safe and efficient handling of the VME-PMC-CADDY. Carefully read this manual before commencing any work and follow the instructions. The manual is a product component, please retain it for future use.
  • Page 3 Chaptee “Front Panel with LEDs” moved New Chapter “Hardware Installation” Chapter “Connector Assignments” moved Chapter “Order Information” moved and revised Technical details are subject to change without further notice. VME-PMC-CADDY Hardware Manual • Doc. No.: V.1911.21 / Rev. 1.9 Page 3 of 33...
  • Page 4 This NOTICE statement contains the general mandatory sign and gives information that must be heeded and complied with for a safe use. INFORMATION INFORMATION Notes to point out something important or useful. Page 4 of 33 Hardware Manual • Doc. No.: V.1911.21 / Rev. 1.9 VME-PMC-CADDY...
  • Page 5: Safety Instructions

    EMC or EMI protection requirements are necessary. Intended Use The intended use of the VME-PMC-CADDY is the operation as a carrier board for PMC modules in a VME-system. The guarantee given by esd does not cover damages which result from improper use, usage not in accordance with regulations or disregard of safety instructions and warnings.
  • Page 6 ● The operation of the VME-PMC-CADDY for medical purposes is prohibited. Service Note The VME-PMC-CADDY does not contain any parts that require maintenance by the user. The VME- PMC-CADDY does not require any manual configuration of the hardware. Unauthorized intervention in the device voids warranty claims.
  • Page 7: Table Of Contents

    IRQ-Mapping on PCI-Bus, Coding Switch S300............18 Configuration Resistors......................19 2.2.1 Changing the P2-Assignment via RX500...RX507............19 2.2.2 3.3V Supply Voltage via VMEbus (RX620...RX625)............20 Address Assignment of the VME-PMC-CADDY................21 Front Panel with LEDs........................ 22 Hardware Installation........................23 Connector Assignments......................24 VMEbus P1.......................... 24 Standard Assignment of I/O-Signals..................25 6.2.1...
  • Page 8: Overview

    Connectors Figure 1: Block circuit diagram of VME-PMC-CADDY The VMEbus unit VME-PMC-CADDY is a VME64-basis board which can carry up to two single- size PMC modules or one double-size module. By means of the VME-PCI bridge UNIVERSE CA91C142 by IDT ®...
  • Page 9 PMC-module in slot 1 with the interrupt lines of the PMC-module in slot 2. The front panel of the VME-PMC-CADDY has two cut-outs for the front panels of the PMC- modules. A blank cover for unused positions is part of the product package.
  • Page 10: Technical Data

    VMEbus connector 160-pole VG connector (IEC 603-xx), acc. to VME64 extension standard LEDs VMEbus interrupt - red LED VMEbus access - yellow LED Table 2: VMEbus data Page 10 of 33 Hardware Manual • Doc. No.: V.1911.21 / Rev. 1.9 VME-PMC-CADDY...
  • Page 11: Pmc Positions

    Drivers for further operating systems are available on request. Please state your operating system with the version number when you order. VME-PMC-CADDY Hardware Manual • Doc. No.: V.1911.21 / Rev. 1.9 Page 11 of 33...
  • Page 12: Pcb View, Coding Switches, Configuration Resistors

    PCB View, Coding Switches, Configuration Resistors 2. PCB View, Coding Switches, Configuration Resistors Figure 2: Position of connectors and configuration resistors on the VME-PMC-CADDY NOTICE Read chapter “Hardware Installation” on page 23, before you start with the installation of the hardware! Page 12 of 33 Hardware Manual •...
  • Page 13 Figure 3: Position of coding switches and configuration resistors on the bottom layer of the PCB See also from page 24 for signal assignment of the connectors. VME-PMC-CADDY Hardware Manual • Doc. No.: V.1911.21 / Rev. 1.9 Page 13 of 33...
  • Page 14: Coding Switches

    PCI-slave image in PCI-memory space (if enabled) address modifier for access by PCI to VMEbus is set to A16-address area (but not enabled). least decoded VMEbus address = A31 of PCI-address Page 14 of 33 Hardware Manual • Doc. No.: V.1911.21 / Rev. 1.9 VME-PMC-CADDY...
  • Page 15 IRQ-mapping on PCI-bus (INTA1 ↔ INTB2): disabled * Note: S300 is equipped for special cases only. S300 is not equipped on the VME-PMC-CADDY versions with the following order numbers: V.1911.01, V.1911.02, V.1911.10 and V.1911.11. Table 4: Position of coding switches at delivery of the VME-PMC-CADDY VME-PMC-CADDY Hardware Manual •...
  • Page 16: Slave Register And Am For Accesses By The Vmebus Master (S203)

    S203 - Switch 5 Selected address area Space 1 Space 0 A24 (default) not permissible Table 6: Selection of the VMEbus address area via coding switch S203 Page 16 of 33 Hardware Manual • Doc. No.: V.1911.21 / Rev. 1.9 VME-PMC-CADDY...
  • Page 17: Vmebus Base Address, Csr-Translation Offset (S202)

    VME control and status reg. in PCI-memory space VME-CSR translation offset (A20 = 0) VME-CSR translation offset (A19 = 0) VME-CSR translation offset (A18 = 0) Table 7: Coding switch S202 VME-PMC-CADDY Hardware Manual • Doc. No.: V.1911.21 / Rev. 1.9 Page 17 of 33...
  • Page 18: Irq-Mapping On Pci-Bus, Coding Switch S300

    INFORMATION S300 is equipped for special cases only. S300 is not equipped on the VME-PMC-CADDY standard versions with order numbers V.1911.01, V.1911.10 and V.1911.11. The IRQ-mapping on the PCI-bus can be set via coding switch S300. The interrupt lines of the PMC-modules in slot 1 and 2 are routed to the VMEbus.
  • Page 19: Configuration Resistors

    Changing the component equipment may only be carried out by esd! Warranty is void if modifications of the product are made by others than by esd. VME-PMC-CADDY Hardware Manual • Doc. No.: V.1911.21 / Rev. 1.9 Page 19 of 33...
  • Page 20: Supply Voltage Via Vmebus (Rx620

    Changing the component equipment may only be carried out by esd! Warranty is void if modifications of the product are made by others than by esd. Page 20 of 33 Hardware Manual • Doc. No.: V.1911.21 / Rev. 1.9 VME-PMC-CADDY...
  • Page 21: Address Assignment Of The Vme-Pmc-Caddy

    Address Assignment of the VME-PMC-CADDY 3. Address Assignment of the VME-PMC-CADDY The VMEbus-base address of the PCI-bridge component is set via the coding switches. In default setting it is: Access: Address: 0x70 00 00 In the appendix of the manual of the PCI-bridge component (Appendix A: Register) the registers are specified which can be accessed via the base address specified above (with according offset).
  • Page 22: Front Panel With Leds

    Interrupt-LED (red): LED is on, if an interrupt is triggered on the VMEbus. Busy-LED (yellow): BUSY LED is on, if the board is accessed by the VMEbus. Page 22 of 33 Hardware Manual • Doc. No.: V.1911.21 / Rev. 1.9 VME-PMC-CADDY...
  • Page 23: Hardware Installation

    Install the PMC boards on the VME-PMC-CADDY carrier board. If necessary, configure the coding switches as described in chapter “Coding Switches” on page 14. Insert the VME-PMC-CADDY board into the selected VME slot. Carefully push the board until it snaps into place. Close the system's case again.
  • Page 24: Connector Assignments

    +5 V Male connector in accordance with DIN41612 design C96/a+b+c per pin: 1.0 A ┐ ┘... Signals bridged on board - ... Signal not connected on board Page 24 of 33 Hardware Manual • Doc. No.: V.1911.21 / Rev. 1.9 VME-PMC-CADDY...
  • Page 25: Standard Assignment Of I/O-Signals

    I/O246 I/O162 I/O161 I/O164 +5 V I/O163 Male connector in accordance with DIN41612 design C96/a+b+c per pin: 1.0 A - ... Signal not connected on board VME-PMC-CADDY Hardware Manual • Doc. No.: V.1911.21 / Rev. 1.9 Page 25 of 33...
  • Page 26: Standard Assignment Of An Interface Module With Signals Of Rows A And C From P2

    I/O140 I/O139 I/O142 I/O141 I/O144 I/O143 I/O146 I/O145 I/O148 I/O147 I/O150 I/O149 I/O152 I/O151 I/O154 I/O153 I/O156 I/O155 I/O158 I/O157 I/O160 I/O159 I/O162 I/O161 I/O164 I/O163 Page 26 of 33 Hardware Manual • Doc. No.: V.1911.21 / Rev. 1.9 VME-PMC-CADDY...
  • Page 27: Standard Assignment Of Pmc-Connector J14

    I/O142 I/O143 I/O144 I/O145 I/O146 I/O147 I/O148 I/O149 I/O150 I/O151 I/O152 I/O153 I/O154 I/O155 I/O156 I/O157 I/O158 I/O159 I/O160 I/O161 I/O162 I/O163 I/O164 Female connector 2x32 VME-PMC-CADDY Hardware Manual • Doc. No.: V.1911.21 / Rev. 1.9 Page 27 of 33...
  • Page 28: Standard Assignment Of Pmc-Connector J24

    I/O242 I/O243 I/O244 I/O245 I/O246 I/O247 I/O248 I/O249 I/O250 I/O251 I/O252 I/O253 I/O254 I/O255 I/O256 I/O257 I/O258 I/O249 I/O260 I/O261 I/O262 I/O263 I/O264 Female connector 2x32 Page 28 of 33 Hardware Manual • Doc. No.: V.1911.21 / Rev. 1.9 VME-PMC-CADDY...
  • Page 29: Assignment Of I/O-Signals When Using Option '-32P2

    I/O246+I/O114 I/O162 I/O161 I/O164 +5 V I/O163 Male connector in accordance with DIN41612 design C96/a+b+c per pin: 1.0 A - ... Signal not connected on board VME-PMC-CADDY Hardware Manual • Doc. No.: V.1911.21 / Rev. 1.9 Page 29 of 33...
  • Page 30: Assignment Of An Interface Module At Option '-32P2

    I/O140 I/O139 I/O142 I/O141 I/O144 I/O143 I/O146 I/O145 I/O148 I/O147 I/O150 I/O149 I/O152 I/O151 I/O154 I/O153 I/O156 I/O155 I/O158 I/O157 I/O160 I/O159 I/O162 I/O161 I/O164 I/O163 Page 30 of 33 Hardware Manual • Doc. No.: V.1911.21 / Rev. 1.9 VME-PMC-CADDY...
  • Page 31: Assignment Of Pmc-Connector J14 At Option '-32P2

    Pin 9 of PMC-connector J14 is connected to pin 41 of PMC-connector J24. Furthermore, pin 9 is connected to pins c5 and z27 of VMEbus connector P2. In the circuit diagrams the signal names I/O109 and I/O241 are used for this network. VME-PMC-CADDY Hardware Manual • Doc. No.: V.1911.21 / Rev. 1.9 Page 31 of 33...
  • Page 32: Assignment Of Pmc-Connector J24 At Option '-32P2

    I/O121 I/O254 I/O122 I/O255 I/O123 I/O256 I/O124 I/O257 I/O125 I/O258 I/O126 I/O249 I/O127 I/O260 I/O128 I/O261 I/O129 I/O262 I/O130 I/O263 I/O131 I/O264 I/O132 Female connector 2x32 Page 32 of 33 Hardware Manual • Doc. No.: V.1911.21 / Rev. 1.9 VME-PMC-CADDY...
  • Page 33: Order Information

    Please download the manuals as PDF documents from our esd website www.esd.eu for free. Manuals Order No. VME-PMC-CADDY-ME Hardware manual in English V.1911.21 Table 9: Available manuals Printed Manuals If you need a printout of the manual additionally, please contact our sales team: sales@esd.eu...

Table of Contents